메뉴 건너뛰기




Volumn 101, Issue 2, 2004, Pages 276-278

Sleeping with uncertainty: Anesthetics and desiccated absorbent

Author keywords

[No Author keywords available]

Indexed keywords

ABSORBENT; ANESTHETIC AGENT; CALCIUM OXIDE; CARBON DIOXIDE; CARBON MONOXIDE; CYCLOPROPANE; DESICCANT; OXYGEN; SEVOFLURANE;

EID: 3342991591     PISSN: 00033022     EISSN: None     Source Type: Journal    
DOI: 10.1097/00000542-200408000-00005     Document Type: Editorial
Times cited : (18)

References (14)
  • 1
    • 3342892913 scopus 로고    scopus 로고
    • Acute respiratory distress syndrome after an exothermic Baralyme®-sevoflurane reaction
    • Fatheree RS, Leighton BL: Acute respiratory distress syndrome after an exothermic Baralyme®-sevoflurane reaction. ANESTHESIOLOGY, 2004; 101:531-3
    • (2004) Anesthesiology , vol.101 , pp. 531-533
    • Fatheree, R.S.1    Leighton, B.L.2
  • 2
    • 3342934770 scopus 로고    scopus 로고
    • Spontaneous ignition, explosion, and fire with sevoflurane and barium hydroxide lime
    • Wu J, Previte JP, Adler E, Myers T, Ball J, Gunter JB: Spontaneous ignition, explosion, and fire with sevoflurane and barium hydroxide lime. ANESTHESIOLOGY, 2004; 101:534-7
    • (2004) Anesthesiology , vol.101 , pp. 534-537
    • Wu, J.1    Previte, J.P.2    Adler, E.3    Myers, T.4    Ball, J.5    Gunter, J.B.6
  • 3
    • 3342933009 scopus 로고    scopus 로고
    • Explosion within an Aestiva anesthesia machine: Baralyme®, high fresh gas flows and sevoflurane concentration
    • Castro BA, Freedman LA, Craig WL, Lynch C: Explosion within an Aestiva anesthesia machine: Baralyme®, high fresh gas flows and sevoflurane concentration. ANESTHESIOLOGY 2004, 101:537-9
    • (2004) Anesthesiology , vol.101 , pp. 537-539
    • Castro, B.A.1    Freedman, L.A.2    Craig, W.L.3    Lynch, C.4
  • 4
    • 0031917935 scopus 로고    scopus 로고
    • Die reakton von sevofluran mit trockenem atemkalk: Überlegungen anläßlich eines aktuellen Zwischenfalls
    • Baum J, Sitte T, Straus JM, Forst H, Zimmermann H, Kugler B: Die reakton von sevofluran mit trockenem atemkalk: Überlegungen anläßlich eines aktuellen Zwischenfalls. Anästhesiol Intensivmedizin 1998; 39:11-6
    • (1998) Anästhesiol Intensivmedizin , vol.39 , pp. 11-16
    • Baum, J.1    Sitte, T.2    Straus, J.M.3    Forst, H.4    Zimmermann, H.5    Kugler, B.6
  • 6
    • 0032909493 scopus 로고    scopus 로고
    • Severe intraoperative CO poisoning: Should apathy prevail?
    • Woehlck HJ: Severe intraoperative CO poisoning: Should apathy prevail? ANESTHESIOLOGY 1999; 90:353-4
    • (1999) Anesthesiology , vol.90 , pp. 353-354
    • Woehlck, H.J.1
  • 7
    • 1442328558 scopus 로고    scopus 로고
    • Hazard Report: Anesthesia carbon dioxide absorber fires
    • Dec 2003 reprinted update
    • ECRI Editorial Staff: Hazard Report: Anesthesia carbon dioxide absorber fires. Health Devices 2003; 32:436-40 (Dec 2003 reprinted update)
    • (2003) Health Devices , vol.32 , pp. 436-440
  • 8
    • 0034956001 scopus 로고    scopus 로고
    • The carbon dioxide absorption capacity of Amsorb® is half that of soda lime
    • Higuchi H, Adachi Y, Arimura S, Kanno M, Satoh T: The carbon dioxide absorption capacity of Amsorb® is half that of soda lime. Anesth Analg 2001; 93:221-5
    • (2001) Anesth Analg , vol.93 , pp. 221-225
    • Higuchi, H.1    Adachi, Y.2    Arimura, S.3    Kanno, M.4    Satoh, T.5
  • 9
    • 3342940767 scopus 로고    scopus 로고
    • Inhibition of carbon monoxide formation from desflurane breakdown by desiccated barium hydroxide lime
    • Woehlck HJ, Dunning III MB: Inhibition of carbon monoxide formation from desflurane breakdown by desiccated barium hydroxide lime (abstract). ANESTHESIOLOGY 2003; 99:A1238
    • (2003) Anesthesiology , vol.99
    • Woehlck, H.J.1    Dunning III, M.B.2
  • 10
    • 0031278933 scopus 로고    scopus 로고
    • Performance of an electrochemical carbon monoxide monitor in the presence of anesthetic gases
    • Dunning M 3rd, Woehlck HJ: Performance of an electrochemical carbon monoxide monitor in the presence of anesthetic gases. J Clin Monit 1997; 13:357-62
    • (1997) J Clin Monit , vol.13 , pp. 357-362
    • Dunning III, M.1    Woehlck, H.J.2
  • 11
    • 0242300726 scopus 로고    scopus 로고
    • Investigation of electrochemical carbon monoxide sensor monitoring of anesthetic gas mixtures
    • Bermudez JA: Investigation of electrochemical carbon monoxide sensor monitoring of anesthetic gas mixtures. ANESTHESIOLOGY 2003; 99:1233-5
    • (2003) Anesthesiology , vol.99 , pp. 1233-1235
    • Bermudez, J.A.1
  • 12
    • 3342899153 scopus 로고    scopus 로고
    • Yellow discoloration of barium hydroxide lime indicates desiccation
    • Dunning III MB, Earth CD, Woehlck HJ: Yellow discoloration of barium hydroxide lime indicates desiccation (abstract). ANESTHESIOLOGY 2003; 99:A626
    • (2003) Anesthesiology , vol.99
    • Dunning III, M.B.1    Earth, C.D.2    Woehlck, H.J.3
  • 13
    • 0038265518 scopus 로고    scopus 로고
    • 2 absorbents on drying: An in vitro study using moisture analysis
    • 2 absorbents on drying: An In vitro study using moisture analysis. Anesth Analg 2003; 97:151-5
    • (2003) Anesth Analg , vol.97 , pp. 151-155
    • Knolle, E.1    Linert, W.2    Gilly, H.3
  • 14
    • 0036112442 scopus 로고    scopus 로고
    • Soda lime temperatures during low-flow sevoflurane anaesthesia and differences in dead space
    • Luttropp HH, Johansson A: Soda lime temperatures during low-flow sevoflurane anaesthesia and differences in dead space. Acta Anaesthesiol Scand 2002; 46:500-5
    • (2002) Acta Anaesthesiol Scand , vol.46 , pp. 500-505
    • Luttropp, H.H.1    Johansson, A.2