메뉴 건너뛰기




Volumn 19, Issue 5, 2004, Pages 661-663

Dislocation of polyethylene liner in uncemented Harris Galante II acetabulum: Report of 6 cases

Author keywords

failure fixation; polyethylene liner; revision hip surgery

Indexed keywords

BONE CEMENT; POLYETHYLENE;

EID: 3342948358     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2003.09.017     Document Type: Article
Times cited : (10)

References (9)
  • 1
    • 0015152820 scopus 로고
    • A new total hip implant
    • Harris W.H. A new total hip implant. Clin Orthop Rel Res. 81:1971;105
    • (1971) Clin Orthop Rel Res , vol.81 , pp. 105
    • Harris, W.H.1
  • 2
    • 0032959892 scopus 로고    scopus 로고
    • Late failure of the polyetheylene liner fixation in an uncemented total hip arthroplasty
    • Louwerse R.T., Heyligers I.C. Late failure of the polyetheylene liner fixation in an uncemented total hip arthroplasty. J Arthroplasty. 14:1999;3
    • (1999) J Arthroplasty , vol.14 , pp. 3
    • Louwerse, R.T.1    Heyligers, I.C.2
  • 4
    • 0032071068 scopus 로고    scopus 로고
    • Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement
    • Kurtz S.M., Ochoa J.A., White C.V., et al. Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. J Biomechanics. 31:1998;431
    • (1998) J Biomechanics , vol.31 , pp. 431
    • Kurtz, S.M.1    Ochoa, J.A.2    White, C.V.3
  • 5
    • 0025678867 scopus 로고
    • The biomechanical problem of polyethylene as a bearing surface
    • Collier J.P., Mayor M.B., Surprenant V.A., et al. The biomechanical problem of polyethylene as a bearing surface. Clin Orthop Rel Res. 261:1990;107
    • (1990) Clin Orthop Rel Res , vol.261 , pp. 107
    • Collier, J.P.1    Mayor, M.B.2    Surprenant, V.A.3
  • 6
    • 0033050961 scopus 로고    scopus 로고
    • Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs
    • Pradhan R. Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs. J Bone Joint Surg Br. 81:1999;431
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 431
    • Pradhan, R.1
  • 7
    • 0031059184 scopus 로고    scopus 로고
    • Fixation of ultrahigh-molecular-weight polyethylene liners to metal-backed acetabular cups
    • Williams V.G., Whiteside L.A., White S.E., McCarthy D.S. Fixation of ultrahigh-molecular-weight polyethylene liners to metal-backed acetabular cups. J Arthroplasty. 12:1997;1
    • (1997) J Arthroplasty , vol.12 , pp. 1
    • Williams, V.G.1    Whiteside, L.A.2    White, S.E.3    McCarthy, D.S.4
  • 8
    • 0027195238 scopus 로고
    • Late dissassembly of modular acetabular components: A report of two cases Acta Orthop
    • Retpen J.B., Solgaard S. Late dissassembly of modular acetabular components a report of two cases Acta Orthop. Scand. 64:1993;193
    • (1993) Scand , vol.64 , pp. 193
    • Retpen, J.B.1    Solgaard, S.2
  • 9
    • 85130082105 scopus 로고    scopus 로고
    • Dislodgement of polyethylene liners in teh first and second generation Harris-Galante acetabular components
    • Valle A.G.D., Ruzo P.S., Li S., et al. Dislodgement of polyethylene liners in teh first and second generation Harris-Galante acetabular components. J Bone Joint Surg Am. 83:2001;4
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 4
    • Valle, A.G.D.1    Ruzo, P.S.2    Li, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.