메뉴 건너뛰기




Volumn 17, Issue 8, 2004, Pages 913-915

Combination of acceleration and collision involving the left atrial appendage limbus as a mechanism of hemolytic anemia in the setting of periprosthetic mitral valve regurgitation

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANAMNESIS; APNEA; ARTICLE; CASE REPORT; CORONARY ARTERY BYPASS GRAFT; ENDOCARDITIS; FATIGUE; FEMALE; HEMOLYSIS; HEMOLYTIC ANEMIA; HUMAN; HUMAN CELL; MITRAL VALVE REGURGITATION; MUSCLE WEAKNESS; THREE DIMENSIONAL IMAGING;

EID: 3342946964     PISSN: 08947317     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.echo.2004.04.015     Document Type: Article
Times cited : (2)

References (11)
  • 1
    • 0033562636 scopus 로고    scopus 로고
    • Intravascular hemolysis after mitral and aortic valve replacement with different types of mechanical prosthesis
    • Ismeno G., Renzulli A., Carozza A., De Feo M., Iannuzzi M., Sante P., et al. Intravascular hemolysis after mitral and aortic valve replacement with different types of mechanical prosthesis. Int J Cardiol. 69:1999;179-183
    • (1999) Int J Cardiol , vol.69 , pp. 179-183
    • Ismeno, G.1    Renzulli, A.2    Carozza, A.3    De Feo, M.4    Iannuzzi, M.5    Sante, P.6
  • 2
    • 0023889381 scopus 로고
    • Intractable hemolysis caused by perivalvular leakage following mitral valve replacement with St Jude Medical prosthesis
    • Okita Y., Miki S., Kusuhara K., Ueda Y., Tahata T., Tsukamoto Y., et al. Intractable hemolysis caused by perivalvular leakage following mitral valve replacement with St Jude Medical prosthesis. Ann Thorac Surg. 46:1988;89-92
    • (1988) Ann Thorac Surg , vol.46 , pp. 89-92
    • Okita, Y.1    Miki, S.2    Kusuhara, K.3    Ueda, Y.4    Tahata, T.5    Tsukamoto, Y.6
  • 3
    • 0345214526 scopus 로고    scopus 로고
    • Mechanisms of hemolysis after mitral valve repair: Assessment by serial echocardiography
    • Yeo T.C., Freeman W.K., Schaff H.V., Orszulak T.A. Mechanisms of hemolysis after mitral valve repair assessment by serial echocardiography. J Am Coll Cardiol. 32:1998;717-723
    • (1998) J Am Coll Cardiol , vol.32 , pp. 717-723
    • Yeo, T.C.1    Freeman, W.K.2    Schaff, H.V.3    Orszulak, T.A.4
  • 4
    • 0031856856 scopus 로고    scopus 로고
    • Evaluation of hemolysis in patients with prosthetic heart valves
    • Maraj R., Jacobs L., Ioli A., Kotler M. Evaluation of hemolysis in patients with prosthetic heart valves. Clin Cardiol. 21:1998;387-392
    • (1998) Clin Cardiol , vol.21 , pp. 387-392
    • Maraj, R.1    Jacobs, L.2    Ioli, A.3    Kotler, M.4
  • 5
    • 0030024768 scopus 로고    scopus 로고
    • Mechanisms of hemolysis with mitral prosthetic regurgitation: Study using transesophageal echocardiography and fluid dynamic stimulation
    • Garcia M.J., Vandervoort P., Stewart W.J., Lytle B.W., Cosgrove D.M. III, Thomas J.D., et al. Mechanisms of hemolysis with mitral prosthetic regurgitation study using transesophageal echocardiography and fluid dynamic stimulation. J Am Coll Cardiol. 27:1996;399-406
    • (1996) J Am Coll Cardiol , vol.27 , pp. 399-406
    • Garcia, M.J.1    Vandervoort, P.2    Stewart, W.J.3    Lytle, B.W.4    Cosgrove III, D.M.5    Thomas, J.D.6
  • 6
    • 0025873901 scopus 로고
    • Paraprosthetic leak: A complication of cardiac valve replacement
    • Jindani A., Neville E.M., Venn G., Williams B.T. Paraprosthetic leak a complication of cardiac valve replacement. J Cardiovasc Surg. 32:1991;503-508
    • (1991) J Cardiovasc Surg , vol.32 , pp. 503-508
    • Jindani, A.1    Neville, E.M.2    Venn, G.3    Williams, B.T.4
  • 7
    • 0020681750 scopus 로고
    • Factors associated with periprosthetic leakage following primary mitral valve replacement: With special consideration of suture technique
    • Dhasmana J.P., Blackstone E.H., Kirklin J.W., Kouchoukos N.T. Factors associated with periprosthetic leakage following primary mitral valve replacement with special consideration of suture technique. Ann Thorac Surg. 35:1983;170-178
    • (1983) Ann Thorac Surg , vol.35 , pp. 170-178
    • Dhasmana, J.P.1    Blackstone, E.H.2    Kirklin, J.W.3    Kouchoukos, N.T.4
  • 8
    • 0027511274 scopus 로고
    • Frequency and severity of intravascular hemolysis after left-sided cardiac valve replacement with Medtronic Hall and St Jude Medical prosthesis, and influence of prosthetic type, position, size, number
    • Skoularigis J., Essop M., Skudicky D., Middlemost S., Sareli P. Frequency and severity of intravascular hemolysis after left-sided cardiac valve replacement with Medtronic Hall and St Jude Medical prosthesis, and influence of prosthetic type, position, size, number. Am J Cardiol. 71:1993;587-591
    • (1993) Am J Cardiol , vol.71 , pp. 587-591
    • Skoularigis, J.1    Essop, M.2    Skudicky, D.3    Middlemost, S.4    Sareli, P.5
  • 9
    • 0030036944 scopus 로고    scopus 로고
    • Medical progress: Prosthetic heart valves
    • Vongpatanasin W., Hillis L., Lange R. Medical progress prosthetic heart valves. N Engl J Med. 335:1996;407-416
    • (1996) N Engl J Med , vol.335 , pp. 407-416
    • Vongpatanasin, W.1    Hillis, L.2    Lange, R.3
  • 10
    • 0026691711 scopus 로고
    • Erythropoietin therapy obviates the need for recurrent transfusions in a patient with severe hemolysis due to prosthetic valves
    • Kornowski R., Schwartz D., Jaffe A., Pines A., Aderka D., Levo Y. Erythropoietin therapy obviates the need for recurrent transfusions in a patient with severe hemolysis due to prosthetic valves. Chest. 102:1992;315-316
    • (1992) Chest , vol.102 , pp. 315-316
    • Kornowski, R.1    Schwartz, D.2    Jaffe, A.3    Pines, A.4    Aderka, D.5    Levo, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.