Volumn 21, Issue 6, 1998, Pages 387-392

Evaluation of hemolysis in patients with prosthetic heart valves

Author keywords

Bioprosthetic valves; Doppler studies; Echocardiography; Hemolysis; Paraprosthetic valvular regurgitation; Prosthetic valves

Indexed keywords

CLINICAL FEATURE; COLOR ULTRASOUND FLOWMETRY; DIAGNOSTIC APPROACH ROUTE; DISEASE SEVERITY; HEART VALVE PROSTHESIS; HEART VALVE REGURGITATION; HEMOLYSIS; HEMOLYTIC ANEMIA; HUMAN; HUMAN TISSUE; IMAGE ANALYSIS; PATHOPHYSIOLOGY; REVIEW; TRANSTHORACIC ECHOCARDIOGRAPHY;

EID: 0031856856     PISSN: 01609289     EISSN: None     Source Type: Journal    
DOI: 10.1002/clc.4960210604     Document Type: Review
Times cited : (56)

References (34)
  • 1
    • 0026438210 scopus 로고
    • The first step to understanding valve failure: An overview ofpathology
    • Schoen FJ The first step to understanding valve failure: An overview ofpathology. Eur. J Cardiothorac Surg 1992;6(Pt 1):50-53
    • (1992) Eur. J Cardiothorac Surg , vol.6 , pp. 50-53
    • Schoen, F.J.1
  • 2
    • 0016691619 scopus 로고    scopus 로고
    • Diagnosis and management of complications of prosthetic heart valves
    • Kloster FE Diagnosis and management of complications of prosthetic heart valves. Am J Cardiol I975;35:872-885
    • Am J Cardiol I , vol.975 , pp. 872-885
    • Kloster, F.E.1
  • 3
    • 0020681750 scopus 로고
    • Factors associated with periprosthetic leakage following primary mitral valve replacement: With special consideration of the suture techniques
    • Dhasmana JP, Blackstone EH, Kirklin JW, Kouchoukos NT: Factors associated with periprosthetic leakage following primary mitral valve replacement: With special consideration of the suture techniques in Thornc Surg 1983;35:170-178
    • (1983) Thornc Surg , vol.35 , pp. 170-178
    • Dhasmana, J.P.1    Blackstone, E.H.2    Kirklin, J.W.3    Kouchoukos, N.T.4
  • 4
    • 0027397532 scopus 로고
    • Mitral and aortic paravalvular leaks with hemolytic anemia
    • Amidon TM, Chou TM, Rankin JS, Ports TA Mitral and aortic paravalvular leaks with hemolytic anemia. Am Heart J 1993; 125:266-268
    • (1993) Am Heart J , vol.125 , pp. 266-268
    • Amidon, T.M.1    Chou, T.M.2    Rankin, J.S.3    Ports, T.A.4
  • 5
    • 0014511152 scopus 로고
    • Hemolytic anemia following prosthetic valve replacement
    • Rodgers BM, Sabiston DC Jr Hemolytic anemia following prosthetic valve replacement. Circulation 1969;39(Pt 1):155-161
    • (1969) Circulation , vol.39 , pp. 155-161
    • Rodgers, B.M.1    Sabiston Jr., D.C.2
  • 7
    • 0018193052 scopus 로고
    • Hemolytic anemia associated with heterograft replacement of the mitral valve
    • Myers TJ, Hild DH, Rinaldi MJ Hemolytic anemia associated with heterograft replacement of the mitral valve. J Thorac Cardiovasc Surg 1978;76:214-215
    • (1978) J Thorac Cardiovasc Surg , vol.76 , pp. 214-215
    • Myers, T.J.1    Hild, D.H.2    Rinaldi, M.J.3
  • 8
    • 0014517415 scopus 로고
    • Intravascular hemolysis in patients with prosthetic valves and valvular heart disease
    • Walsh JR, Starr A, Ritzmann LW: Intravascular hemolysis in patients with prosthetic valves and valvular heart disease, emulation 1969;39(Pt 1):135-140
    • (1969) Emulation , vol.39 , pp. 135-140
    • Walsh, J.R.1    Starr, A.2    Ritzmann, L.W.3
  • 10
    • 0014317668 scopus 로고
    • Paravalvular leaks and hemolytic anemia following insertion of Starr-Ed wards aortic and mitral valves
    • Kastor JA, Buckley MJ, Sanders CA, Austen WG Paravalvular leaks and hemolytic anemia following insertion of Starr-Ed wards aortic and mitral valves. J Thorac Cardiovasc Surg 1968;56: 279-288
    • (1968) J Thorac Cardiovasc Surg , vol.56 , pp. 279-288
    • Kastor, J.A.1    Buckley, M.J.2    Sanders, C.A.3    Austen, W.G.4
  • 14
    • 0019670403 scopus 로고
    • Structure and classification of cuspal tears and perforations in porcine bio-prosthetic cardiac valves implanted in patients
    • IshiharaT, Ferrans VJ, Boyce SW, Jones M, Roberts WC Structure and classification of cuspal tears and perforations in porcine bio-prosthetic cardiac valves implanted in patients. Am J Cardiol 1981:48:665-678
    • (1981) Am J Cardiol , vol.48 , pp. 665-678
    • Ishihara, T.1    Ferrans, V.J.2    Boyce, S.W.3    Jones, M.4    Roberts, W.C.5
  • 15
    • 0028237010 scopus 로고
    • Pathology of substitute heart valves: New concepts and developments
    • Schoen FJ, Levy RJ Pathology of substitute heart valves: New concepts and developments. J Cardiol Surg 1994;9(Pt 1):222-227
    • (1994) J Cardiol Surg , vol.9 , pp. 222-227
    • Schoen, F.J.1    Levy, R.J.2
  • 19
    • 0021142481 scopus 로고
    • Modification by the Hancock T6 process of calcification of bioprosthetic cardiac valves implanted in sheep
    • Arbustini E, Jones M, Moses RD, Eidbo EE, Carroll RJ, Ferrans VJ Modification by the Hancock T6 process of calcification of bioprosthetic cardiac valves implanted in sheep. Am J Cardiol 1984; 53:1388-1396
    • (1984) Am J Cardiol , vol.53 , pp. 1388-1396
    • Arbustini, E.1    Jones, M.2    Moses, R.D.3    Eidbo, E.E.4    Carroll, R.J.5    Ferrans, V.J.6
  • 20
    • 0027196041 scopus 로고
    • Comparison of outcomes in men 11 years after heart-valve replacement with a mechanical valve or bioprosthesis
    • Hammermeister KE, Sethi GK, Henderson WO, Oprian C, Kim T, Rahimtoola A Comparison of outcomes in men 11 years after heart-valve replacement with a mechanical valve or bioprosthesis. N Engl J Med 1993;328:1289-1296
    • (1993) N Engl J Med , vol.328 , pp. 1289-1296
    • Hammermeister, K.E.1    Sethi, G.K.2    Henderson, W.O.3    Oprian, C.4    Kim, T.5    Rahimtoola, A.6
  • 21
  • 22
    • 0023135835 scopus 로고
    • Hemolytic anemia and acute mitral regurgitation caused by a torn cusp of a porcine mitral prosthetic valve 7 years after its implantation
    • Schaer DH, Cheng TO, Aaron BL Hemolytic anemia and acute mitral regurgitation caused by a torn cusp of a porcine mitral prosthetic valve 7 years after its implantation. Am Heart J1987; 113:404-406
    • (1987) Am Heart J , vol.113 , pp. 404-406
    • Schaer, D.H.1    Cheng, T.O.2    Aaron, B.L.3
  • 23
    • 0025150687 scopus 로고
    • Microangiopathic hemolytic anemia as the initial manifestation of porcine valve failure
    • Enzenauer RJ, Berenberg JL, Cassell PF Jr Microangiopathic hemolytic anemia as the initial manifestation of porcine valve failure. South MedJ 1990:83:912-917
    • (1990) South MedJ , vol.83 , pp. 912-917
    • Enzenauer, R.J.1    Berenberg, J.L.2    Cassell Jr., P.F.3
  • 24
    • 0029019118 scopus 로고
    • Hemolytic anemia secondary to a porcine mitral prosthetic valve leaflet dissection
    • Brown MR, Hasaniya NWMA, Dang CR Hemolytic anemia secondary to a porcine mitral prosthetic valve leaflet dissection. Ann Thontc Siirg 1995;59:1573-1574
    • (1995) Ann Thontc Siirg , vol.59 , pp. 1573-1574
    • Brown, M.R.1    Hasaniya, N.W.M.A.2    Dang, C.R.3
  • 25
    • 0027420921 scopus 로고
    • Long-term management of prosthetic valves
    • DeSilvey DL Long-term management of prosthetic valves. Heart DisStroke 1993;2:493-496
    • (1993) Heart DisStroke , vol.2 , pp. 493-496
    • DeSilvey, D.L.1
  • 27
    • 0020675726 scopus 로고
    • Indexes of intravascular hemolysis, quantification of coagulation factors, and platelet survival in patients with porcine heterograft valves
    • Thompson ME, Lewis JH, Porkolab FL, Hasiba U, Spero JA, Wilson J, Snyder M Indexes of intravascular hemolysis, quantification of coagulation factors, and platelet survival in patients with porcine heterograft valves. Am J Cardiol 1983 ;51:489-491
    • (1983) Am J Cardiol , vol.51 , pp. 489-491
    • Thompson, M.E.1    Lewis, J.H.2    Porkolab, F.L.3    Hasiba, U.4    Spero, J.A.5    Wilson, J.6    Snyder, M.7
  • 28
    • 0019209087 scopus 로고
    • Chronic intravascular hemolysis after aortic valve replacement with lonescu-Shiley xenograft: Comparative study with BjorkShiley prosthesis
    • Febres-Roman PR, Bourg WC, Crone RA, Davis RC Jr, Williams TH Chronic intravascular hemolysis after aortic valve replacement with lonescu-Shiley xenograft: Comparative study with BjorkShiley prosthesis. Am J Cardiol 1980;46:735-738
    • (1980) Am J Cardiol , vol.46 , pp. 735-738
    • Febres-Roman, P.R.1    Bourg, W.C.2    Crone, R.A.3    Davis Jr., R.C.4    Williams, T.H.5
  • 29
    • 0015144017 scopus 로고
    • Chronic intravascular hemolysis after aortic valve replacement
    • Eyster E, Rothchild J, Mychajliw O Chronic intravascular hemolysis after aortic valve replacement. Circulation 1971;44:657-665
    • (1971) Circulation , vol.44 , pp. 657-665
    • Eyster, E.1    Rothchild, J.2    Mychajliw, O.3
  • 32
    • 0025164421 scopus 로고
    • Detection of prosthetic mitral valve leak: A comparative study using transesophageal echocardiography, transthoracic echocardiography, and auscultation
    • Chen Y, Kan MCI, Lin W, Chang M, Hu W, Hwang D, Lee D, Hwang S, Chiang BN Detection of prosthetic mitral valve leak: A comparative study using transesophageal echocardiography, transthoracic echocardiography, and auscultation. J Clin Ultrasound 1990:18:557-561
    • (1990) J Clin Ultrasound , vol.18 , pp. 557-561
    • Chen, Y.1    Kan, M.C.I.2    Lin, W.3    Chang, M.4    Hu, W.5    Hwang, D.6    Lee, D.7    Hwang, S.8    Chiang, B.N.9
  • 33
    • 0028512964 scopus 로고
    • Long-term follow-up of mitral paraprosthetic regurgitation by transesophageal echocardiography
    • Movsowitz HD, Shah SI, loli A, Kotler MN, Jacobs LE Long-term follow-up of mitral paraprosthetic regurgitation by transesophageal echocardiography. JAm Soc Ecliocardiol 1994:7:488-492
    • (1994) JAm Soc Ecliocardiol , vol.7 , pp. 488-492
    • Movsowitz, H.D.1    Shah, S.I.2    Loli, A.3    Kotler, M.N.4    Jacobs, L.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.