메뉴 건너뛰기




Volumn 30, Issue 11, 2003, Pages 1498-1504

Comparison of 180° and 360° data acquisition for determination of left ventricular function from gated myocardial perfusion tomography and gated blood pool tomography

Author keywords

180 versus 360 acquisition; Gated blood pool tomography; Gated myocardial perfusion tomography; Left ventricular function

Indexed keywords

SERUM ALBUMIN; TETROFOSMIN TC 99M; DIAGNOSTIC AGENT; MACROSALB TC 99M; ORGANOPHOSPHORUS COMPOUND; RADIOPHARMACEUTICAL AGENT; TECHNETIUM COMPLEX; TECHNETIUM TC 99M 1,2 BIS(BIS(2 ETHOXYETHYL)PHOSPHINO)ETHANE; TECHNETIUM TC 99M 1,2-BIS(BIS(2-ETHOXYETHYL)PHOSPHINO)ETHANE;

EID: 3342880958     PISSN: 16197070     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00259-003-1267-1     Document Type: Article
Times cited : (16)

References (21)
  • 1
    • 0019964916 scopus 로고
    • Comparison of 180° and 360° data collection in thallium-201 imaging using single-photon emission computerized tomography (SPECT): Concise communication
    • Coleman RE, Jaszczak RJ, Cobb FR. Comparison of 180° and 360° data collection in thallium-201 imaging using single-photon emission computerized tomography (SPECT): concise communication. J Nucl Med 1982; 23:655-660.
    • (1982) J Nucl Med , vol.23 , pp. 655-660
    • Coleman, R.E.1    Jaszczak, R.J.2    Cobb, F.R.3
  • 2
    • 0024468067 scopus 로고
    • Investigation of causes of geometric distortion in 180° and 360° angular sampling in SPECT
    • Knesaurek K, King MA, Glick SJ, Penny BC. Investigation of causes of geometric distortion in 180° and 360° angular sampling in SPECT. J Nucl Med 1989; 30:1666-1675.
    • (1989) J Nucl Med , vol.30 , pp. 1666-1675
    • Knesaurek, K.1    King, M.A.2    Glick, S.J.3    Penny, B.C.4
  • 3
    • 0019968630 scopus 로고
    • 180° compared with 360° sampling in SPECT
    • Hoffman EJ. 180° compared with 360° sampling in SPECT. J Nucl Med 1982; 23:745-747.
    • (1982) J Nucl Med , vol.23 , pp. 745-747
    • Hoffman, E.J.1
  • 4
    • 0036323081 scopus 로고    scopus 로고
    • Differential effect of 180° and 360° acquisition orbits on the accuracy of SPECT imaging: Quantitative evaluation in phantoms
    • Liu YH, Lam PT, Sinusas AJ, Wackers FJ. Differential effect of 180° and 360° acquisition orbits on the accuracy of SPECT imaging: quantitative evaluation in phantoms. J Nucl Med 2002; 43:1115-1124.
    • (2002) J Nucl Med , vol.43 , pp. 1115-1124
    • Liu, Y.H.1    Lam, P.T.2    Sinusas, A.J.3    Wackers, F.J.4
  • 6
    • 0031883725 scopus 로고    scopus 로고
    • Clinical comparison of 180° and 360° data collection of technetium 99m sestamibi SPECT for detection of coronary artery disease
    • Freeman MR, Konstantinou C, Barr A, Greysin NC. Clinical comparison of 180° and 360° data collection of technetium 99m sestamibi SPECT for detection of coronary artery disease. J Nucl Cardiol 1998; 5:14-18.
    • (1998) J Nucl Cardiol , vol.5 , pp. 14-18
    • Freeman, M.R.1    Konstantinou, C.2    Barr, A.3    Greysin, N.C.4
  • 7
    • 0022810962 scopus 로고
    • Fundamentals of 180 degree acquisition and reconstruction in SPECT imaging
    • Eisner RL, Nowak DJ, Pettigrew R, et al. Fundamentals of 180 degree acquisition and reconstruction in SPECT imaging. J Nucl Med 1986; 27:1717-1728.
    • (1986) J Nucl Med , vol.27 , pp. 1717-1728
    • Eisner, R.L.1    Nowak, D.J.2    Pettigrew, R.3
  • 8
    • 0024636739 scopus 로고
    • Comparison between 180 degree and 360 degree data collection in technetium-99m MIBI SPECT of the myocardium
    • Maublant JC, Peycelon P, Kwiatkowski F, et al. Comparison between 180 degree and 360 degree data collection in technetium-99m MIBI SPECT of the myocardium. J Nucl Med 1989; 30:295-300.
    • (1989) J Nucl Med , vol.30 , pp. 295-300
    • Maublant, J.C.1    Peycelon, P.2    Kwiatkowski, F.3
  • 9
    • 0035083339 scopus 로고    scopus 로고
    • Updated imaging guidelines for nuclear cardiology procedures
    • DePuey EG, Garcia EV. Updated imaging guidelines for nuclear cardiology procedures. J Nucl Cardiol 2001; 8: G1-G58.
    • (2001) J Nucl Cardiol , vol.8
    • DePuey, E.G.1    Garcia, E.V.2
  • 13
    • 0028807605 scopus 로고
    • Automatic quantification of ejection fraction from gated myocardial perfusion SPECT
    • Germano G, Kiat H, Kavanagh PB, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995; 36:2138-2147.
    • (1995) J Nucl Med , vol.36 , pp. 2138-2147
    • Germano, G.1    Kiat, H.2    Kavanagh, P.B.3
  • 14
    • 0035097959 scopus 로고    scopus 로고
    • Automatic determination of left ventricular ejection fraction from gated blood pool tomography
    • Vanhove C, Franken PR, Defrise M, Momen A, Everaert H, Bossuyt A. Automatic determination of left ventricular ejection fraction from gated blood pool tomography. J Nucl Med 2001; 42:401-407.
    • (2001) J Nucl Med , vol.42 , pp. 401-407
    • Vanhove, C.1    Franken, P.R.2    Defrise, M.3    Momen, A.4    Everaert, H.5    Bossuyt, A.6
  • 15
    • 0034897937 scopus 로고    scopus 로고
    • Left ventricular ejection fraction and volumes from gated blood pool tomography: Comparison between two automatic algorithms working in three-dimensional space
    • Vanhove C, Franken PR. Left ventricular ejection fraction and volumes from gated blood pool tomography: comparison between two automatic algorithms working in three-dimensional space. J Nucl Cardiol 2001; 8:466-471.
    • (2001) J Nucl Cardiol , vol.8 , pp. 466-471
    • Vanhove, C.1    Franken, P.R.2
  • 16
    • 0036594841 scopus 로고    scopus 로고
    • Gated myocardial perfusion tomography versus gated blood pool tomography to calculate left ventricular volumes and ejection fraction
    • Vanhove C, Walgraeve N, De Geeter F, Franken PR. Gated myocardial perfusion tomography versus gated blood pool tomography to calculate left ventricular volumes and ejection fraction. Eur J Nucl Med 2002; 29:735-741.
    • (2002) Eur J Nucl Med , vol.29 , pp. 735-741
    • Vanhove, C.1    Walgraeve, N.2    De Geeter, F.3    Franken, P.R.4
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurements
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurements. Lancet 1986; 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 0036261655 scopus 로고    scopus 로고
    • Accuracy and reproducibility of left ventricular function from quantitative, gated, single photon emission computed tomography using dynamic myocardial phantoms: Effect of pre-reconstruction filters
    • Kubo N, Mabuchi M, Katoh C, et al. Accuracy and reproducibility of left ventricular function from quantitative, gated, single photon emission computed tomography using dynamic myocardial phantoms: effect of pre-reconstruction filters. Nucl Med Commun 2002; 23:529-536.
    • (2002) Nucl Med Commun , vol.23 , pp. 529-536
    • Kubo, N.1    Mabuchi, M.2    Katoh, C.3
  • 19
    • 0033858106 scopus 로고    scopus 로고
    • Gated SPET quantification of small hearts: Mathematical simulation and clinical application
    • Nakajima K, Taki J, Higuchi T, et al. Gated SPET quantification of small hearts: mathematical simulation and clinical application. Eur J Nucl Med 2000; 27:1372-1379.
    • (2000) Eur J Nucl Med , vol.27 , pp. 1372-1379
    • Nakajima, K.1    Taki, J.2    Higuchi, T.3
  • 20
    • 0031923598 scopus 로고    scopus 로고
    • An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package on simulated gated SPECT images
    • Achert A, King MA, Dahlberg ST, et al. An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package on simulated gated SPECT images. J Nucl Cardiol 1998; 5:144-152.
    • (1998) J Nucl Cardiol , vol.5 , pp. 144-152
    • Achert, A.1    King, M.A.2    Dahlberg, S.T.3
  • 21
    • 0034796989 scopus 로고    scopus 로고
    • Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: Comparison of 4 software programs
    • Nakajima K, Higuchi T, Taki J, Kawano M, Tonami N. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. J Nucl Med 2001; 42:1571-1578.
    • (2001) J Nucl Med , vol.42 , pp. 1571-1578
    • Nakajima, K.1    Higuchi, T.2    Taki, J.3    Kawano, M.4    Tonami, N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.