An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package in simulated gated SPECT images

Author keywords

[No Author keywords available]

Indexed keywords

TECHNETIUM 99M;

EID: 0031923598     PISSN: 10713581     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1071-3581(98)90197-0     Document Type: Article
Times cited : (78)

References (11)
  • 1
    • 0024457885 scopus 로고
    • Myocardial gated tomoscintigraphy with Tc-99m-methoxy-isobutyl-isonitrile (MIBI): Regional and temporal activity curve analysis
    • Grucker D, Florentz P, Oswald T, Chambron J. Myocardial gated tomoscintigraphy with Tc-99m-methoxy-isobutyl-isonitrile (MIBI): regional and temporal activity curve analysis. Nucl Med Comm 1989;10:723-32.
    • (1989) Nucl Med Comm , vol.10 , pp. 723-732
    • Grucker, D.1    Florentz, P.2    Oswald, T.3    Chambron, J.4
  • 2
    • 0026345219 scopus 로고
    • Three-dimensional motion and perfusion quantification in gated single-photon emission computed tomograms
    • Faber TL, Akers MS, Peshock RM, Corbett JR. Three-dimensional motion and perfusion quantification in gated single-photon emission computed tomograms. J Nucl Med 1991;32:2311-7.
    • (1991) J Nucl Med , vol.32 , pp. 2311-2317
    • Faber, T.L.1    Akers, M.S.2    Peshock, R.M.3    Corbett, J.R.4
  • 4
    • 0027442739 scopus 로고
    • Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT
    • DePuey EG, Nichols K, Dobrinsky C. Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT. J Nucl Med 1993;34:1871-6.
    • (1993) J Nucl Med , vol.34 , pp. 1871-1876
    • DePuey, E.G.1    Nichols, K.2    Dobrinsky, C.3
  • 5
    • 0028807605 scopus 로고
    • Automatic quantification of ejection fraction from gated myocardial perfusion SPECT
    • Germano G, Kiat H, Kavanagh PB, Moriel M, Mazzanti M, Su H-T, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med 1995;36:2138-47.
    • (1995) J Nucl Med , vol.36 , pp. 2138-2147
    • Germano, G.1    Kiat, H.2    Kavanagh, P.B.3    Moriel, M.4    Mazzanti, M.5    Su, H.-T.6
  • 6
    • 0030071191 scopus 로고    scopus 로고
    • Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images
    • Williams KA, Taillon LA. Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images. J Am Coll Cardiol 1996;27:173-81.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 173-181
    • Williams, K.A.1    Taillon, L.A.2
  • 7
    • 0030453611 scopus 로고    scopus 로고
    • Automation of gated tomographic left ventricular ejection fraction
    • Nichols K, DePuey EG, Rozanski A. Automation of gated tomographic left ventricular ejection fraction. J Nucl Cardiol 1996;3:475-82.
    • (1996) J Nucl Cardiol , vol.3 , pp. 475-482
    • Nichols, K.1    DePuey, E.G.2    Rozanski, A.3
  • 8
    • 0030761578 scopus 로고    scopus 로고
    • Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom
    • Preforius PH, Xia W, King MA, Tsui BMW, Pan T-S, Villegas BJ. Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom. J Nucl Med 1997;38:1528-35.
    • (1997) J Nucl Med , vol.38 , pp. 1528-1535
    • Preforius, P.H.1    Xia, W.2    King, M.A.3    Tsui, B.M.W.4    Pan, T.-S.5    Villegas, B.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.