메뉴 건너뛰기




Volumn 21, Issue 1, 2006, Pages 162-170

Analysis of multistress-accelerated aged stator bars using a three-phase test arrangement

Author keywords

Ac breakdown; Accelerated aging; Degradation; Diagnostic tests; Multistress; Partial discharge; Stator bars

Indexed keywords

AGING OF MATERIALS; DEGRADATION; PARTIAL DISCHARGES; THERMAL STRESS;

EID: 33244492874     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2006.870047     Document Type: Article
Times cited : (12)

References (24)
  • 1
    • 10244253825 scopus 로고
    • "A utilities' functional evaluation test for high voltage stator insulation"
    • A. W. W. Cameron and M. Kurtz, "A utilities' functional evaluation test for high voltage stator insulation," IEEE Trans. Power App. Syst., vol. 78, no. Part III, pp. 178-184, 1959.
    • (1959) IEEE Trans. Power App. Syst. , vol.78 , Issue.PART III , pp. 178-184
    • Cameron, A.W.W.1    Kurtz, M.2
  • 2
    • 0003070716 scopus 로고
    • "A quality control test for high voltage stator insulation"
    • Sep
    • B. E. Ward, G. C. Stone, and M. Kurtz, "A quality control test for high voltage stator insulation," IEEE Electr. Insul. Mag., vol. 3, pp. 12-17, Sep. 1987.
    • (1987) IEEE Electr. Insul. Mag. , vol.3 , pp. 12-17
    • Ward, B.E.1    Stone, G.C.2    Kurtz, M.3
  • 3
    • 0026370875 scopus 로고
    • "A thermal cycling test for generator stator insulation"
    • Dec
    • G. C. Stone, J. F. Lyles, J. M. Brown, and C. I. Paul, "A thermal cycling test for generator stator insulation," IEEE Trans. Energy Convers., vol. 6, no. 4, pp. 707-713, Dec. 1991.
    • (1991) IEEE Trans. Energy Convers. , vol.6 , Issue.4 , pp. 707-713
    • Stone, G.C.1    Lyles, J.F.2    Brown, J.M.3    Paul, C.I.4
  • 4
    • 0026986196 scopus 로고
    • "Relationship between partial discharge pulse-height analysis and subsequent voltage endurance of stator bars and coils"
    • Dec
    • W. McDermid and J. C. Bromley, "Relationship between partial discharge pulse-height analysis and subsequent voltage endurance of stator bars and coils," IEEE Trans. Energy Convers., vol. 7, no. 4, pp. 721-731, Dec. 1992.
    • (1992) IEEE Trans. Energy Convers. , vol.7 , Issue.4 , pp. 721-731
    • McDermid, W.1    Bromley, J.C.2
  • 7
    • 0028255398 scopus 로고
    • "Multiple stress aging of solid dielectric extruded dry-cured insulation systems for power transmission cables"
    • Jan
    • R. J. Densley, R. Bartnikas, and B. Bernstein, "Multiple stress aging of solid dielectric extruded dry-cured insulation systems for power transmission cables," IEEE Trans. Powers Del., vol. 9, no. 1, pp. 559-571, Jan. 1994.
    • (1994) IEEE Trans. Powers Del. , vol.9 , Issue.1 , pp. 559-571
    • Densley, R.J.1    Bartnikas, R.2    Bernstein, B.3
  • 9
    • 0019241158 scopus 로고
    • "Capability of insulation diagnosis of mica-resin insulated coils"
    • K. Kadotani and Y. Kako, "Capability of insulation diagnosis of mica-resin insulated coils," IEEE Trans. Electr. Insul., vol. EI-15, p. 981, 1980.
    • (1980) IEEE Trans. Electr. Insul. , vol.EI-15 , pp. 981
    • Kadotani, K.1    Kako, Y.2
  • 10
    • 0019556141 scopus 로고
    • "Correlations between non-destructive and destructive tests on high voltage coil insulations for rotating machines"
    • T. Tsukui, M. Takamura, and Y. Kako, "Correlations between non-destructive and destructive tests on high voltage coil insulations for rotating machines," IEEE Trans. Electr. Insul., vol. EI-15, p. 118, 1980.
    • (1980) IEEE Trans. Electr. Insul. , vol.EI-15 , pp. 118
    • Tsukui, T.1    Takamura, M.2    Kako, Y.3
  • 11
    • 0020705301 scopus 로고
    • "A proposal for insulation diagnosis of 3 kV motor stator windings"
    • K. Kadotani, T. Hadaonada, and S. Yamatake, "A proposal for insulation diagnosis of 3 kV motor stator windings," IEEE Trans. Electr. Insul., vol. 18, pp. 59-63, 1983.
    • (1983) IEEE Trans. Electr. Insul. , vol.18 , pp. 59-63
    • Kadotani, K.1    Hadaonada, T.2    Yamatake, S.3
  • 13
    • 0022877133 scopus 로고
    • "Insulation diagnosis for rotating machine insulation"
    • H. Yoshida and K. Umemoto, "Insulation diagnosis for rotating machine insulation," IEEE Trans. Electr. Insul., vol. EI-21, pp. 1021-1025, 1986.
    • (1986) IEEE Trans. Electr. Insul. , vol.EI-21 , pp. 1021-1025
    • Yoshida, H.1    Umemoto, K.2
  • 14
    • 0022907780 scopus 로고
    • "Test methods of rotating machines"
    • H. Yoshida and Y. Inoue, "Test methods of rotating machines," IEEE Trans. Electr. Insul., vol. EI-21, pp. 1069-1071, 1986.
    • (1986) IEEE Trans. Electr. Insul. , vol.EI-21 , pp. 1069-1071
    • Yoshida, H.1    Inoue, Y.2
  • 15
    • 0026914386 scopus 로고
    • "Assessment of insulation condition in rotating machine stators"
    • Sep
    • B. K. Gupta and I. M. Culbert, "Assessment of insulation condition in rotating machine stators," IEEE Trans. Energy Convers., vol. 7, no. 3, pp. 500-508, Sep. 1992.
    • (1992) IEEE Trans. Energy Convers. , vol.7 , Issue.3 , pp. 500-508
    • Gupta, B.K.1    Culbert, I.M.2
  • 16
    • 0023985019 scopus 로고
    • "A-C breakdown characteristics of in-service aged XLPE distribution cables"
    • Apr
    • R. Bartnikas, S. Pélissou, and H. St-Onge, "A-C breakdown characteristics of in-service aged XLPE distribution cables," IEEE Trans. Power Del., vol. 3, no. 2, pp. 454-462, Apr. 1988.
    • (1988) IEEE Trans. Power Del. , vol.3 , Issue.2 , pp. 454-462
    • Bartnikas, R.1    Pélissou, S.2    St-Onge, H.3
  • 17
    • 0024122491 scopus 로고
    • "The ability of diagnostic tests to estimate the remaining life of stator insulation"
    • Dec
    • G. C. Stone, H. G. Sedding, B. A. Lloyd, and B. K. Gupta, "The ability of diagnostic tests to estimate the remaining life of stator insulation," IEEE Trans. Energy Convers., vol. EC-3, no. 4, pp. 833-841, Dec. 1988.
    • (1988) IEEE Trans. Energy Convers. , vol.EC-3 , Issue.4 , pp. 833-841
    • Stone, G.C.1    Sedding, H.G.2    Lloyd, B.A.3    Gupta, B.K.4
  • 18
    • 0034204541 scopus 로고    scopus 로고
    • "A three phase multi-stress accelerated aging test facility for stator bars"
    • Jun
    • R. Morin, R. Bartnikas, and P. Ménard, "A three phase multi-stress accelerated aging test facility for stator bars," IEEE Trans. Energy Convers., vol. 15, no. 2, pp. 149-156, Jun. 2000.
    • (2000) IEEE Trans. Energy Convers. , vol.15 , Issue.2 , pp. 149-156
    • Morin, R.1    Bartnikas, R.2    Ménard, P.3
  • 19
    • 10244229102 scopus 로고    scopus 로고
    • "Multi-stress aging of stator bars with electrical, thermal and mechanical stresses as simultaneous acceleration factors"
    • Dec
    • R. Bartnikas and R. Morin, "Multi-stress aging of stator bars with electrical, thermal and mechanical stresses as simultaneous acceleration factors," IEEE Trans. Energy Convers., vol. 19, no. 4, pp. 702-714, Dec. 2004.
    • (2004) IEEE Trans. Energy Convers. , vol.19 , Issue.4 , pp. 702-714
    • Bartnikas, R.1    Morin, R.2
  • 22
    • 0018985113 scopus 로고
    • "Analysis of the propagation of electrical treeing using optical and electrical methods"
    • C. Laurent and C. Mayoux, "Analysis of the propagation of electrical treeing using optical and electrical methods," IEEE Trans Electr. Insul., vol. E1-15, pp. 33-42, 1980.
    • (1980) IEEE Trans Electr. Insul. , vol.E1-15 , pp. 33-42
    • Laurent, C.1    Mayoux, C.2
  • 23
    • 0027540045 scopus 로고
    • "Spark to glow discharge transition due to increase of surface conductivity on epoxy resin specimens"
    • Feb
    • C. Hudon, R. Bartnikas, and M. R. Wertheimer, "Spark to glow discharge transition due to increase of surface conductivity on epoxy resin specimens," IEEE Trans. Electr. Insul., vol. 28, no. 1, pp. 1-8, Feb. 1993.
    • (1993) IEEE Trans. Electr. Insul. , vol.28 , Issue.1 , pp. 1-8
    • Hudon, C.1    Bartnikas, R.2    Wertheimer, M.R.3
  • 24
    • 85042203849 scopus 로고
    • "Research to determine the acceptable emergency operating temperature of extruded dielectric cables"
    • Electrical Power Research Institute, Palo Alto, Report EL-938
    • S. Onge, R. Bartnikas, M. Braunovic, C. de Tourreil, and M. Duval, "Research to determine the acceptable emergency operating temperature of extruded dielectric cables," Electrical Power Research Institute, Palo Alto, Report EL-938, 1978.
    • (1978)
    • Onge, S.1    Bartnikas, R.2    Braunovic, M.3    de Tourreil, C.4    Duval, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.