Volumn 19, Issue 4, 2004, Pages 702-714

Multi-stress aging of stator bars with electrical, thermal, and mechanical stresses as simultaneous acceleration factors

Author keywords

Accelerated aging; Degradation; Multi stress; Partial discharge; Stator bars; Three phase system

Indexed keywords

AGING OF MATERIALS; COMPUTER SIMULATION; ELECTRIC CURRENTS; MATHEMATICAL MODELS; PARTIAL DISCHARGES; THERMAL STRESS;

EID: 10244229102     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2004.832060     Document Type: Article
Times cited : (39)

References (30)
  • 1
    • 0034204541 scopus 로고    scopus 로고
    • "A three phase multi-stress accelerated electrical aging test facility for stator bars"
    • June
    • R. Morin, R. Bartnikas, and P. Ménard, "A three phase multi-stress accelerated electrical aging test facility for stator bars," IEEE Trans. Energy Conversion, vol. 15, pp. 149-156, June 2000.
    • (2000) IEEE Trans. Energy Conversion , vol.15 , pp. 149-156
    • Morin, R.1    Bartnikas, R.2    Ménard, P.3
  • 2
    • 0004251816 scopus 로고
    • R. Bartnikas, Ed. Philadelphia/West Conshohocken: ASTM, Measurement Techniques
    • W. D. Wilkens, Engineering Dielectrics, R. Bartnikas, Ed. Philadelphia/West Conshohocken: ASTM, 1987, vol. IIB, Measurement Techniques.
    • (1987) Engineering Dielectrics , vol.2 B
    • Wilkens, W.D.1
  • 4
    • 84935408604 scopus 로고
    • "Electrical insulation deterioration treated as a chemical rate phenomena"
    • T. W. Dakin, "Electrical insulation deterioration treated as a chemical rate phenomena," AIEE Trans. Part I (Commun. Electron. , vol. 67, pp. 113-122, 1948.
    • (1948) AIEE Trans. Part I (Commun. Electron.) , vol.67 , pp. 113-122
    • Dakin, T.W.1
  • 5
    • 0017998267 scopus 로고
    • "Insulation aging: An historical and critical review"
    • Aug
    • E. Brancato, "Insulation aging: An historical and critical review," IEEE Trans. Elect. Insulation, vol. EI-13, pp. 308-317, Aug. 1978.
    • (1978) IEEE Trans. Elect. Insulation , vol.EI-13 , pp. 308-317
    • Brancato, E.1
  • 11
    • 0031355806 scopus 로고    scopus 로고
    • "Development of a vertical generator stator bar insulation system for operation at increased stress"
    • Chicago, IL, Sept
    • R. E. Draper and B. J. Moore, "Development of a vertical generator stator bar insulation system for operation at increased stress," in Proc. Electrical Insulation Conf., Chicago, IL, Sept. 22-25, 1997.
    • (1997) Proc. Electrical Insulation Conf. , pp. 22-25
    • Draper, R.E.1    Moore, B.J.2
  • 12
    • 0031381917 scopus 로고    scopus 로고
    • "A utility evaluation of a stator bar insulation system operating at increased electric stress"
    • Chicago, IL, Sept
    • W. McDermid, "A utility evaluation of a stator bar insulation system operating at increased electric stress," in Proc. Electrical Insulation Conf., Chicago, IL, Sept. 22-25, 1997.
    • (1997) Proc. Electrical Insulation Conf. , pp. 22-25
    • McDermid, W.1
  • 13
    • 0019606553 scopus 로고
    • "A general approach to the endurance of electrical insulation under temperature and voltage"
    • Aug
    • L. Simoni, "A general approach to the endurance of electrical insulation under temperature and voltage," IEEE Trans. Elect. Insulation, vol. EI-16, pp. 277-289, Aug. 1981.
    • (1981) IEEE Trans. Elect. Insulation , vol.EI-16 , pp. 277-289
    • Simoni, L.1
  • 14
    • 10244253825 scopus 로고
    • "A utility's functional evaluation test for high voltage stator insulation"
    • A. W. W. Cameron and M. Kurtz, "A utility's functional evaluation test for high voltage stator insulation," AIEE Trans. Power App. Syst. pt. III, vol. 78, pp. 178-184, 1959.
    • (1959) AIEE Trans. Power App. Syst. , vol.78 , Issue.PART III , pp. 178-184
    • Cameron, A.W.W.1    Kurtz, M.2
  • 15
    • 0003070716 scopus 로고
    • "A quality control test for high voltage stator insulation"
    • B. E. Ward, G. C. Stone, and M. Kurtz, "A quality control test for high voltage stator insulation," IEEE Elect. Insulation Mag., vol. 3, pp. 12-17, 1987.
    • (1987) IEEE Elect. Insulation Mag. , vol.3 , pp. 12-17
    • Ward, B.E.1    Stone, G.C.2    Kurtz, M.3
  • 16
    • 0026370875 scopus 로고
    • "A thermal cycling test for generator stator winding insulation"
    • Dec
    • G. C. Stone, J. F. Lyles, J.-M. Braun, and C. L. Paul, "A thermal cycling test for generator stator winding insulation," IEEE Trans. Energy Conversion, vol. 6, pp. 707-713, Dec. 1991.
    • (1991) IEEE Trans. Energy Conversion , vol.6 , pp. 707-713
    • Stone, G.C.1    Lyles, J.F.2    Braun, J.-M.3    Paul, C.L.4
  • 17
    • 0026986196 scopus 로고
    • "Relationship between partial discharge pulse-height analysis and subsequent voltage endurance of stator bars and coils"
    • Dec
    • W. McDermid and J. C. Bromley, "Relationship between partial discharge pulse-height analysis and subsequent voltage endurance of stator bars and coils," IEEE Trans. Energy Conversion, vol. 7, pp. 721-731, Dec. 1992.
    • (1992) IEEE Trans. Energy Conversion , vol.7 , pp. 721-731
    • McDermid, W.1    Bromley, J.C.2
  • 18
    • 0022880601 scopus 로고
    • "Destructive tests on a 542 MW generator winding"
    • Washington, DC, IEEE Conf. Rec. 86CH2196-4-DEI
    • B. K. Gupta, M. Kurtz, G. C. Stone, and D. K. Sharma, "Destructive tests on a 542 MW generator winding," in Proc. IEEE Int. Symp. Electrical Insulation, Washington, DC, 1986, IEEE Conf. Rec. 86CH2196-4-DEI, pp. 285-288.
    • (1986) Proc. IEEE Int. Symp. Electrical Insulation , pp. 285-288
    • Gupta, B.K.1    Kurtz, M.2    Stone, G.C.3    Sharma, D.K.4
  • 19
    • 0026914386 scopus 로고
    • "Assessment of insulation condition in rotating machine stators"
    • Sept
    • B. K. Gupta and I. M. Culbert, "Assessment of insulation condition in rotating machine stators," IEEE Trans. Energy Conversion, vol. 7, pp. 500-508, Sept. 1992.
    • (1992) IEEE Trans. Energy Conversion , vol.7 , pp. 500-508
    • Gupta, B.K.1    Culbert, I.M.2
  • 20
    • 0024125449 scopus 로고
    • "Experience with PDA diagnostic testing on hydraulic generators"
    • Dec
    • J. F. Lyles, G. C. Stone, and M. Kurtz, "Experience with PDA diagnostic testing on hydraulic generators," IEEE Trans. Energy Conversion, vol. 3, pp. 824-832, Dec. 1988.
    • (1988) IEEE Trans. Energy Conversion , vol.3 , pp. 824-832
    • Lyles, J.F.1    Stone, G.C.2    Kurtz, M.3
  • 21
    • 0024122491 scopus 로고
    • "The ability of diagnostic tests to estimate the remaining life of stator insulation"
    • Dec
    • G. C. Stone, H. G. Sedding, B. A. Lloyd, and B. K. Gupta, "The ability of diagnostic tests to estimate the remaining life of stator insulation," IEEE Trans. Energy Conversion, vol. 3, pp. 833-841, Dec. 1988.
    • (1988) IEEE Trans. Energy Conversion , vol.3 , pp. 833-841
    • Stone, G.C.1    Sedding, H.G.2    Lloyd, B.A.3    Gupta, B.K.4
  • 22
    • 10244250270 scopus 로고
    • "Motor and Generator Insulation Life Estimation"
    • EPRI Rep. TR-100 185
    • "Motor and Generator Insulation Life Estimation,", EPRI Rep. TR-100 185, vol. 1, 1992.
    • (1992) , vol.1
  • 23
    • 0019556141 scopus 로고
    • "Correlations between non-destructive and destructive tests on high-voltage coil insulations for rotating machines"
    • Apr
    • T. Tsukui, M. Takamura, and Y. Kako, "Correlations between non-destructive and destructive tests on high-voltage coil insulations for rotating machines," IEEE Trans. Elect. Insulation, vol. EI-16, pp. 118-127, Apr. 1981.
    • (1981) IEEE Trans. Elect. Insulation , vol.EI-16 , pp. 118-127
    • Tsukui, T.1    Takamura, M.2    Kako, Y.3
  • 24
    • 0022877133 scopus 로고
    • "Insulation diagnosis for rotating machine insulation"
    • Dec
    • H. Yoshida and K. Umemoto, "Insulation diagnosis for rotating machine insulation," IEEE Trans. Elect. Insulation, vol. EI-21, pp. 1021-1025, Dec. 1986.
    • (1986) IEEE Trans. Elect. Insulation , vol.EI-21 , pp. 1021-1025
    • Yoshida, H.1    Umemoto, K.2
  • 26
    • 0004251816 scopus 로고
    • Philadelphia, PA: ASTM, Corona Measurement and Interpretation
    • R. Bartnikas and E. J. McMahon, Engineering Dielectrics. Philadelphia, PA: ASTM, 1979, vol. I, Corona Measurement and Interpretation.
    • (1979) Engineering Dielectrics , vol.1
    • Bartnikas, R.1    McMahon, E.J.2
  • 29
    • 0028255398 scopus 로고
    • "Multiple stress aging of solid dielectric dry-cured insulation systems for power transmission cables"
    • Jan
    • R. J. Densley, R. Bartnikas, and B. Berustein, "Multiple stress aging of solid dielectric dry-cured insulation systems for power transmission cables," IEEE Trans. Power Delivery, vol. 9, pp. 559-571, Jan. 1994.
    • (1994) IEEE Trans. Power Delivery , vol.9 , pp. 559-571
    • Densley, R.J.1    Bartnikas, R.2    Berustein, B.3
  • 30
    • 0027540045 scopus 로고
    • "Spark to glow discharge transition due to increase surface conductivity on epoxy resin specimens"
    • Feb
    • C. Hudon, R. Bartnikas, and M. R. Wertheimer, "Spark to glow discharge transition due to increase surface conductivity on epoxy resin specimens," IEEE Trans. Elect. Insulation, vol. 28, pp. 1-8, Feb. 1993.
    • (1993) IEEE Trans. Elect. Insulation , vol.28 , pp. 1-8
    • Hudon, C.1    Bartnikas, R.2    Wertheimer, M.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.