메뉴 건너뛰기




Volumn 5979, Issue , 2005, Pages

Method for on-site determination of the instrument line shape of mobile remote sensing Fourier transform spectrometers

Author keywords

Air pollution monitoring; Fourier transform spectroscopy; Infrared spectroscopy; Instrument line shape; Remote sensing

Indexed keywords

AIRCRAFT; ALGORITHMS; FOURIER TRANSFORMS; MATHEMATICAL MODELS; REMOTE SENSING; THERMAL PLUMES;

EID: 33244458273     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.627689     Document Type: Conference Paper
Times cited : (8)

References (19)
  • 1
    • 0035613685 scopus 로고    scopus 로고
    • Toxic cloud imaging by infrared spectrometry: A scanning FTIR system for identification and visualization
    • Harig, R., Matz, G.: "Toxic Cloud Imaging by Infrared Spectrometry: A Scanning FTIR System for Identification and Visualization," Field Analytical Chemistry and Technology 5 (1-2), 75-90, 2001.
    • (2001) Field Analytical Chemistry and Technology , vol.5 , Issue.1-2 , pp. 75-90
    • Harig, R.1    Matz, G.2
  • 3
    • 0344369816 scopus 로고    scopus 로고
    • Analysis of aircraft exhausts with Fourier-transform infrared emission spectroscopy
    • Heland, J.; Schäfer, K.: "Analysis of aircraft exhausts with Fourier-transform infrared emission spectroscopy," Applied Optics 36, 4922-4931, 1997.
    • (1997) Applied Optics , vol.36 , pp. 4922-4931
    • Heland, J.1    Schäfer, K.2
  • 5
    • 0002731855 scopus 로고
    • Recherches sur la spectroscopie par la transformation de Fourier
    • 3,4
    • Connes, J., "Recherches sur la spectroscopie par la transformation de Fourier,"Revue d'Optique Théorique et Expérimentale 40 (2,3,4,5), 41-79, 116-140, 171-190, 231-265, 1961.
    • (1961) Revue D'Optique Théorique et Expérimentale , vol.40 , Issue.2-5 , pp. 41-79
    • Connes, J.1
  • 6
    • 0002677312 scopus 로고
    • Some more aspects of the michelson interferometer with cube corners
    • Murty, M.V.R.K., "Some More Aspects of the Michelson Interferometer with Cube Corners," Journal of the Optical Society of America 50, 7-10, 1960.
    • (1960) Journal of the Optical Society of America , vol.50 , pp. 7-10
    • Murty, M.V.R.K.1
  • 7
    • 3543033631 scopus 로고
    • Interferometers without collimation for Fourier spectroscopy
    • Steel, W. H., "Interferometers without collimation for Fourier spectroscopy," Journal of the Optical Society of America 54, 151-156, 1964.
    • (1964) Journal of the Optical Society of America , vol.54 , pp. 151-156
    • Steel, W.H.1
  • 8
    • 0037024710 scopus 로고    scopus 로고
    • Impact of the optical aberrations on the line shape of Fourier-transform spectrometers
    • Genest, J., Tremblay. P.: "Impact of the optical aberrations on the line shape of Fourier-transform spectrometers," Vibrational Spectroscopy 29, 3-13, 2002.
    • (2002) Vibrational Spectroscopy , vol.29 , pp. 3-13
    • Genest, J.1    Tremblay, P.2
  • 9
    • 84975597852 scopus 로고
    • Line-shape distortions in misaligned cube-corner interferometers
    • Kauppinen, J., Saarinen, P., "Line-Shape Distortions in Misaligned Cube-Corner Interferometers," Applied Optics 31, 69-74, 1992.
    • (1992) Applied Optics , vol.31 , pp. 69-74
    • Kauppinen, J.1    Saarinen, P.2
  • 10
    • 0000830286 scopus 로고
    • Spectral line-shape distortions in michelson interferometers due to off-focus radiation source
    • Saarinen, P., Kauppinen, J., "Spectral Line-Shape Distortions in Michelson Interferometers due to Off-Focus Radiation Source," Applied Optics 31, 2353-2359, 1992.
    • (1992) Applied Optics , vol.31 , pp. 2353-2359
    • Saarinen, P.1    Kauppinen, J.2
  • 11
    • 4344564956 scopus 로고    scopus 로고
    • Passive remote sensing of pollutant clouds by FTIR spectrometry: Signal-to-noise ratio as a function of spectral resolution
    • Hang, R.: "Passive remote sensing of pollutant clouds by FTIR spectrometry: Signal-to-noise ratio as a function of spectral resolution," Applied Optics, Volume 43 (23), 4603-4610, 2004.
    • (2004) Applied Optics , vol.43 , Issue.23 , pp. 4603-4610
    • Hang, R.1
  • 12
    • 0032315427 scopus 로고    scopus 로고
    • Quantitative Analysis of flue gas FTIR-spectra employing a new mathematical method to determine the instrumental line shape
    • Spectroscopic Atmospheric Environmental Monitoring Techniques, Klaus Schäfer, Editor
    • Windpassinger, R., "Quantitative Analysis of flue gas FTIR-spectra employing a new mathematical method to determine the instrumental line shape," in Spectroscopic Atmospheric Environmental Monitoring Techniques, Klaus Schäfer, Editor, Proc. SPIE 3493, 64-70, 1998.
    • (1998) Proc. SPIE , vol.3493 , pp. 64-70
    • Windpassinger, R.1
  • 13
    • 0034300813 scopus 로고    scopus 로고
    • Characterisation of instrumental line shape distortions due to path difference dependent phase errors in a Fourier transform spectrometer
    • Bianchini, G., Raspollini, P., "Characterisation of instrumental line shape distortions due to path difference dependent phase errors in a Fourier transform spectrometer," Infrared Physics & Technology 41, 287-292, 2000.
    • (2000) Infrared Physics & Technology , vol.41 , pp. 287-292
    • Bianchini, G.1    Raspollini, P.2
  • 14
    • 0001739095 scopus 로고    scopus 로고
    • Analysis of the instrumental line shape of high-resolution Fourier transform IR spectrometers with gas cell measurements and new retrieval software
    • Hase, F., Blumenstock, T., Paton-Walsh, C., "Analysis of the instrumental line shape of high-resolution Fourier transform IR spectrometers with gas cell measurements and new retrieval software," Applied Optics 38, 3417-3422, 1999.
    • (1999) Applied Optics , vol.38 , pp. 3417-3422
    • Hase, F.1    Blumenstock, T.2    Paton-Walsh, C.3
  • 17
    • 0003703360 scopus 로고
    • U.S. Government Printing Office, Washington, D.C.
    • U.S. Standard Atmosphere, 1976, U.S. Government Printing Office, Washington, D.C., 1976.
    • (1976) U.S. Standard Atmosphere, 1976
  • 18
    • 0035764037 scopus 로고    scopus 로고
    • Scanning infrared remote sensing system for identification, visualization, and quantification of airborne pollutants
    • Instrumentation for Air Pollution and Global Atmospheric Monitoring, James O. Jensen, Robert L. Spellicy, Herausgeber
    • Harig, R., Matz, G., Rusch, P.: "Scanning Infrared Remote Sensing System for Identification, Visualization, and Quantification of Airborne Pollutants" in Instrumentation for Air Pollution and Global Atmospheric Monitoring, James O. Jensen, Robert L. Spellicy, Herausgeber, Proceedings of SPIE Vol. 4574, 83-94, 2002.
    • (2002) Proceedings of SPIE , vol.4574 , pp. 83-94
    • Harig, R.1    Matz, G.2    Rusch, P.3
  • 19
    • 1942516422 scopus 로고    scopus 로고
    • Remote detection of methane by infrared spectrometry for airborne pipeline surveillance: First results of ground-based measurements
    • Remote Sensing of Clouds and the Atmosphere VIII, Schäfer, Comeron, Carleer, Picard, Editors
    • Harig, R., Matz, G., Rusch, P., Gerhard, J.-H., Schäfer, K., Jahn, C., Schwengler, P., Beil, A.: "Remote Detection of Methane by Infrared Spectrometry for Airborne Pipeline Surveillance: First Results of Ground-Based Measurements" in Remote Sensing of Clouds and the Atmosphere VIII, Schäfer, Comeron, Carleer, Picard, Editors, Proceedings of SPIE Vol. 5235, 2004.
    • (2004) Proceedings of SPIE , vol.5235
    • Harig, R.1    Matz, G.2    Rusch, P.3    Gerhard, J.-H.4    Schäfer, K.5    Jahn, C.6    Schwengler, P.7    Beil, A.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.