메뉴 건너뛰기




Volumn 10, Issue 1, 2006, Pages 68-72

Extravascular lung water index: A new method to determine dry weight in chronic hemodialysis patients

Author keywords

Brain natriuretic peptide; Chronic HD; Dry weight; Extravascular lung water

Indexed keywords

ALDOSTERONE; BRAIN NATRIURETIC PEPTIDE; RENIN;

EID: 33144466925     PISSN: 14927535     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1542-4758.2006.01177.x     Document Type: Article
Times cited : (12)

References (19)
  • 1
    • 1642382811 scopus 로고    scopus 로고
    • Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: Implications in clinical practice
    • Ishibe S, Peixoto AJ. Methods of assessment of volume status and intercompartmental fluid shifts in hemodialysis patients: Implications in clinical practice. Semin Dial. 2004; 17:37-43.
    • (2004) Semin Dial. , vol.17 , pp. 37-43
    • Ishibe, S.1    Peixoto, A.J.2
  • 2
    • 0032936433 scopus 로고    scopus 로고
    • Assessment of dry weight in hemodialysis: An overview
    • Jaeger JQ, Metha RL. Assessment of dry weight in hemodialysis: An overview. J Am Soc Nephrol. 1999; 10:392-403.
    • (1999) J Am Soc Nephrol. , vol.10 , pp. 392-403
    • Jaeger, J.Q.1    Metha, R.L.2
  • 3
    • 10744226879 scopus 로고    scopus 로고
    • Association between extracellular water, left ventricular mass and hypertension in hemodialysis patients
    • Faguli RM, Pasini P, Quintaliani G, et al. Association between extracellular water, left ventricular mass and hypertension in hemodialysis patients. Nephrol Dial Transplant. 2003; 18:2332-2338.
    • (2003) Nephrol Dial Transplant. , vol.18 , pp. 2332-2338
    • Faguli, R.M.1    Pasini, P.2    Quintaliani, G.3
  • 4
    • 0037359208 scopus 로고    scopus 로고
    • Ultrafiltration and dry weight - What are the cardiovascular effects?
    • Stegmayr BG. Ultrafiltration and dry weight - what are the cardiovascular effects? Artif Organs. 2003; 27:227-229.
    • (2003) Artif Organs. , vol.27 , pp. 227-229
    • Stegmayr, B.G.1
  • 5
    • 0036893102 scopus 로고    scopus 로고
    • Techniques for assessing and achieving fluid balance in acute renal failure
    • Metha RL, Clark WC, Schetz M. Techniques for assessing and achieving fluid balance in acute renal failure. Curr Opin Crit Care. 2002; 8:535-543.
    • (2002) Curr Opin Crit Care , vol.8 , pp. 535-543
    • Metha, R.L.1    Clark, W.C.2    Schetz, M.3
  • 6
    • 0036377061 scopus 로고    scopus 로고
    • Adjusting dry weight by extracellular volume and body composition in hemodialysis patients
    • Chen YC, Chen HH, Yeh JC, Chen SY. Adjusting dry weight by extracellular volume and body composition in hemodialysis patients. Nephron. 2002; 92:91-96.
    • (2002) Nephron. , vol.92 , pp. 91-96
    • Chen, Y.C.1    Chen, H.H.2    Yeh, J.C.3    Chen, S.Y.4
  • 7
    • 0037385708 scopus 로고    scopus 로고
    • Can technology solve the clinical problem of dry weight?
    • Hoenich NA, Levin NW. Can technology solve the clinical problem of dry weight? Nephrol Dial Transplant. 2003; 18:647-650.
    • (2003) Nephrol Dial Transplant. , vol.18 , pp. 647-650
    • Hoenich, N.A.1    Levin, N.W.2
  • 8
    • 0032973757 scopus 로고    scopus 로고
    • The measurement of lung water
    • Lange NR, Schuster DP. The measurement of lung water. Crit Care. 1999; 3:19-24.
    • (1999) Crit Care , vol.3 , pp. 19-24
    • Lange, N.R.1    Schuster, D.P.2
  • 9
    • 0036786573 scopus 로고    scopus 로고
    • Preload index: Pulmonary artery occlusion pressure versus intrathoracic blood volume monitoring during lung transplantation
    • Della Rocca G, Costa GM, Coccia C, Pompei L, Di Marco P, Pietropaoli P. Preload index: Pulmonary artery occlusion pressure versus intrathoracic blood volume monitoring during lung transplantation. Anesth Analg. 2002; 95:835-843.
    • (2002) Anesth Analg. , vol.95 , pp. 835-843
    • Della Rocca, G.1    Costa, G.M.2    Coccia, C.3    Pompei, L.4    Di Marco, P.5    Pietropaoli, P.6
  • 10
    • 0037865718 scopus 로고    scopus 로고
    • Cardiovascular monitoring tools: Use and misuse
    • Bellomo R, Uchino S. Cardiovascular monitoring tools: Use and misuse. Curr Opin Crit Care. 2003; 9:225-229.
    • (2003) Curr Opin Crit Care. , vol.9 , pp. 225-229
    • Bellomo, R.1    Uchino, S.2
  • 11
    • 0036900820 scopus 로고    scopus 로고
    • Preload and hemodynamic assessment during liver transplantation: A comparison between the pulmonary artery catheter and transpulmonary indicator dilution techniques
    • Della Rocca G, Costa MG, Coccia C, Pompei L, Pietropaoli P. Preload and hemodynamic assessment during liver transplantation: A comparison between the pulmonary artery catheter and transpulmonary indicator dilution techniques. Eur J Anesth. 2002; 19:868-875.
    • (2002) Eur J Anesth. , vol.19 , pp. 868-875
    • Della Rocca, G.1    Costa, M.G.2    Coccia, C.3    Pompei, L.4    Pietropaoli, P.5
  • 12
    • 3142730723 scopus 로고    scopus 로고
    • Accuracy of transpulmonary thermodilution versus gravimetric measurement of extravascular lung water
    • Katzenelson R, Perel A, Berkenstadt H, et al. Accuracy of transpulmonary thermodilution versus gravimetric measurement of extravascular lung water. Crit Care Med. 2004; 32:1550-1554.
    • (2004) Crit Care Med. , vol.32 , pp. 1550-1554
    • Katzenelson, R.1    Perel, A.2    Berkenstadt, H.3
  • 13
    • 5044239930 scopus 로고    scopus 로고
    • Monitoring intravascular volumes to direct hypertensive, hypervolemic therapy in a patient with vasospasm
    • Segal E, Greenlee JD, Hata SJ, Perel A. Monitoring intravascular volumes to direct hypertensive, hypervolemic therapy in a patient with vasospasm. J Neurosurg Anesthesiol. 16:296-298.
    • J Neurosurg Anesthesiol. , vol.16 , pp. 296-298
    • Segal, E.1    Greenlee, J.D.2    Hata, S.J.3    Perel, A.4
  • 14
    • 0031436596 scopus 로고    scopus 로고
    • Lung density for assessment of hydration status in hemodialysis patients using the computed tomogtaphic densitometry technique
    • Metry G, Wegenius G, Wikstrom B, et al. Lung density for assessment of hydration status in hemodialysis patients using the computed tomogtaphic densitometry technique. Kidney Int. 1997; 52:1635-1644.
    • (1997) Kidney Int. , vol.52 , pp. 1635-1644
    • Metry, G.1    Wegenius, G.2    Wikstrom, B.3
  • 16
    • 0013247112 scopus 로고    scopus 로고
    • Extravascular lung water measured by a single indicator technique in dogs. Correlation with gravimetric measurements
    • Katznelson R, Preisman S, Berkenstadt H, et al. Extravascular lung water measured by a single indicator technique in dogs. Correlation with gravimetric measurements. Crit Care Med. 2001; 29:A155.
    • (2001) Crit Care Med. , vol.29
    • Katznelson, R.1    Preisman, S.2    Berkenstadt, H.3
  • 18
    • 0031000643 scopus 로고    scopus 로고
    • Central and regional hemodynamics during acute hypovolemia and volume substitution in volunteers
    • Riddez L, Hahn G, Brismar B, Strandberg A, Svenson C, Hedenstierna G. Central and regional hemodynamics during acute hypovolemia and volume substitution in volunteers. Crit Care Med. 1997; 25:635-640.
    • (1997) Crit Care Med. , vol.25 , pp. 635-640
    • Riddez, L.1    Hahn, G.2    Brismar, B.3    Strandberg, A.4    Svenson, C.5    Hedenstierna, G.6
  • 19
    • 33144466461 scopus 로고    scopus 로고
    • Extravascular lung water and peripheral volume status in hemodialysis patients with a history of heart failure and without
    • (abstract)
    • Joseph G, MacRae JM, Heidenheim AP, Lindsay RM. Extravascular lung water and peripheral volume status in hemodialysis patients with a history of heart failure and without (abstract). J Am Soc Nephrol. 2004; 15:530.
    • (2004) J Am Soc Nephrol. , vol.15 , pp. 530
    • Joseph, G.1    MacRae, J.M.2    Heidenheim, A.P.3    Lindsay, R.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.