Can technology solve the clinical problem of 'dry weight'?

Author keywords

Bioimpedance; Dry weight; Extracellular volume; Fluid removal; Haemodialysis; Hydration

Indexed keywords

BODY FLUID; BODY WEIGHT; EDITORIAL; FLUID RETENTION; HEMODIALYSIS; HUMAN; HYDRATION; HYPERVOLEMIA; HYPOTENSION; IMPEDANCE; INTERSTITIAL FLUID; KIDNEY FAILURE; MEASUREMENT; MEDICAL TECHNOLOGY; NUTRITIONAL STATUS; PREDICTION; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; WEIGHT GAIN;

EID: 0037385708     PISSN: 09310509     EISSN: None     Source Type: Journal    
DOI: 10.1093/ndt/gfg008     Document Type: Editorial
Times cited : (26)

References (34)
  • 1
    • 0036405062 scopus 로고    scopus 로고
    • Blood pressure and longterm mortality in United States hemodialysis patients: USRDS Waves 3 and 4 Study
    • Foley RN, Herzog CA, Collins AJ. Blood pressure and longterm mortality in United States hemodialysis patients: USRDS Waves 3 and 4 Study. Kidney Int 2002; 62: 1784-1790
    • (2002) Kidney Int. , vol.62 , pp. 1784-1790
    • Foley, R.N.1    Herzog, C.A.2    Collins, A.J.3
  • 2
    • 0031762955 scopus 로고    scopus 로고
    • Morbidity and mortality on maintenance haemodialysis
    • Locatelli F, del Vecchio L, Manzoni C. Morbidity and mortality on maintenance haemodialysis. Nephron 1998; 80: 380-400
    • (1998) Nephron. , vol.80 , pp. 380-400
    • Locatelli, F.1    del Vecchio, L.2    Manzoni, C.3
  • 3
    • 0029843821 scopus 로고    scopus 로고
    • Role of volume overload in dialysis-refractory hypertension
    • Fishbane S, Natke E, Maesaka JK. Role of volume overload in dialysis-refractory hypertension. Am J Kidney Dis 1996; 28: 257-261
    • (1996) Am. J. Kidney Dis. , vol.28 , pp. 257-261
    • Fishbane, S.1    Natke, E.2    Maesaka, J.K.3
  • 4
    • 0029900177 scopus 로고    scopus 로고
    • Assessment of dry weight in haemodialysis patients by the volume markers ANP and cGMP
    • Wolfram G, Sitter T, Gottsmann M et al. Assessment of dry weight in haemodialysis patients by the volume markers ANP and cGMP. Nephrol Dial Transplant 1996; 11 [Suppl 2]: 28-30
    • (1996) Nephrol. Dial. Transplant , vol.11 , Issue.SUPPL. 2 , pp. 28-30
    • Wolfram, G.1    Sitter, T.2    Gottsmann, M.3
  • 5
    • 0035206609 scopus 로고    scopus 로고
    • Comparison of body fluid distribution between chronic haemodialysis and peritoneal dialysis patients as assessed by biophysical and biochemical methods
    • Plum J, Schoenicke G, Kleophas W et al. Comparison of body fluid distribution between chronic haemodialysis and peritoneal dialysis patients as assessed by biophysical and biochemical methods. Nephrol Dial Transplant 2001; 16: 2378-2385
    • (2001) Nephrol. Dial. Transplant , vol.16 , pp. 2378-2385
    • Plum, J.1    Schoenicke, G.2    Kleophas, W.3
  • 6
    • 0034965104 scopus 로고    scopus 로고
    • Inferior vena cava diameter: A useful method for estimation of fluid status in children on haemodialysis
    • Krause I, Birk E, Davidovits M et al. Inferior vena cava diameter: a useful method for estimation of fluid status in children on haemodialysis. Nephrol Dial Transplant 2001; 16: 1203-1206
    • (2001) Nephrol. Dial. Transplant , vol.16 , pp. 1203-1206
    • Krause, I.1    Birk, E.2    Davidovits, M.3
  • 7
    • 0032936433 scopus 로고    scopus 로고
    • Assessment of dry weight in hemodialysis: An overview
    • Jaeger JQ, Mehta RL. Assessment of dry weight in hemodialysis: an overview. J Am Soc Nephrol 1999; 10: 392-403
    • (1999) J. Am. Soc. Nephrol. , vol.10 , pp. 392-403
    • Jaeger, J.Q.1    Mehta, R.L.2
  • 8
    • 0036113534 scopus 로고    scopus 로고
    • A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance
    • Chamney PW, Kramer M, Rode C, Kleinekofort W, Wizemann V. A new technique for establishing dry weight in hemodialysis patients via whole body bioimpedance. Kidney Int 2002; 61: 2250-2258
    • (2002) Kidney Int. , vol.61 , pp. 2250-2258
    • Chamney, P.W.1    Kramer, M.2    Rode, C.3    Kleinekofort, W.4    Wizemann, V.5
  • 9
    • 0024572263 scopus 로고
    • Dielectric properties of tissues and biological materials: A critical review
    • Foster KR, Schwan HP. Dielectric properties of tissues and biological materials: a critical review. Crit Rev Biomed Eng 1989; 17: 25-104
    • (1989) Crit. Rev. Biomed. Eng. , vol.17 , pp. 25-104
    • Foster, K.R.1    Schwan, H.P.2
  • 10
    • 0032970507 scopus 로고    scopus 로고
    • Predicting body water changes with bioimpedance using equations derived from mixture theory
    • Matthie JR, Withers PO. Predicting body water changes with bioimpedance using equations derived from mixture theory. Crit Care Med 1999; 27: 1217-1219
    • (1999) Crit. Care Med. , vol.27 , pp. 1217-1219
    • Matthie, J.R.1    Withers, P.O.2
  • 11
    • 0031969180 scopus 로고    scopus 로고
    • Analytic assessment of the various bioimpedance methods used to estimate body water
    • Matthie J, Zarowitz B, de Lorenzo A et al. Analytic assessment of the various bioimpedance methods used to estimate body water. J Appl Physiol 1998; 84: 1801-1816
    • (1998) J. Appl. Physiol. , vol.84 , pp. 1801-1816
    • Matthie, J.1    Zarowitz, B.2    de Lorenzo, A.3
  • 12
    • 0032213550 scopus 로고    scopus 로고
    • Relative underestimation of fluid removal during hemodialysis hypotension measured by whole body bioimpedance
    • Zaluska WT, Schneditz D, Kaufman AM, Morris AT, Levin NW. Relative underestimation of fluid removal during hemodialysis hypotension measured by whole body bioimpedance. ASAIO J 1998; 44: 823-827
    • (1998) ASAIO J. , vol.44 , pp. 823-827
    • Zaluska, W.T.1    Schneditz, D.2    Kaufman, A.M.3    Morris, A.T.4    Levin, N.W.5
  • 13
    • 0032807622 scopus 로고    scopus 로고
    • Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body position
    • Zhu F, Schneditz D, Levin NW. Sum of segmental bioimpedance analysis during ultrafiltration and hemodialysis reduces sensitivity to changes in body position. Kidney Int 1999; 56: 692-699
    • (1999) Kidney Int. , vol.56 , pp. 692-699
    • Zhu, F.1    Schneditz, D.2    Levin, N.W.3
  • 14
    • 0032170001 scopus 로고    scopus 로고
    • Validation of changes in extracellular volume measured during hemodialysis using a segmental bioimpedance technique
    • Zhu F, Schneditz D, Wang E et al. Validation of changes in extracellular volume measured during hemodialysis using a segmental bioimpedance technique. ASAIO J 1998; 44: M541-M545
    • (1998) ASAIO J. , vol.44
    • Zhu, F.1    Schneditz, D.2    Wang, E.3
  • 15
    • 0031928649 scopus 로고    scopus 로고
    • Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis
    • Zhu F, Schneditz D, Wang E, Levin NW. Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis. J Appl Physiol 1998; 85: 497-504
    • (1998) J. Appl. Physiol. , vol.85 , pp. 497-504
    • Zhu, F.1    Schneditz, D.2    Wang, E.3    Levin, N.W.4
  • 16
    • 0029783015 scopus 로고    scopus 로고
    • Use of bioelectrical impedance analysis measurements in the clinical management of patients undergoing dialysis
    • Kushner RF, de Vries PM, Gudivaka R. Use of bioelectrical impedance analysis measurements in the clinical management of patients undergoing dialysis. Am J Clin Nutr 1996; 64 [Suppl]: S503-S509
    • (1996) Am. J. Clin. Nutr. , vol.64 , Issue.SUPPL.
    • Kushner, R.F.1    de Vries, P.M.2    Gudivaka, R.3
  • 17
    • 0026556747 scopus 로고
    • Assessment of post-dialysis dry weight: An application of the conductivity measurement method
    • Kouw PM, Olthof CG, ter Wee PM, Oe LP et al. Assessment of post-dialysis dry weight: an application of the conductivity measurement method. Kidney Int 1992; 41: 440-444
    • (1992) Kidney Int. , vol.41 , pp. 440-444
    • Kouw, P.M.1    Olthof, C.G.2    ter Wee, P.M.3    Oe, L.P.4
  • 18
    • 0036698579 scopus 로고    scopus 로고
    • Age-related extracellular to total body water volume ratio (ECV/TBW): Can it be used for 'dry weight' determination in dialysis patients? Application of multifrequency bioimpedance measurement
    • Lopot F, Nejedly B, Novotna H et al. Age-related extracellular to total body water volume ratio (ECV/TBW): can it be used for 'dry weight' determination in dialysis patients? Application of multifrequency bioimpedance measurement. Int J Artif Organs 2002; 25: 762-769
    • (2002) Int. J. Artif. Organs , vol.25 , pp. 762-769
    • Lopot, F.1    Nejedly, B.2    Novotna, H.3
  • 19
    • 0030012199 scopus 로고    scopus 로고
    • Assessment of excess fluid distribution in chronic hemodialysis patients using bioimpedance spectroscopy
    • Fisch BJ, Spiegel DM. Assessment of excess fluid distribution in chronic hemodialysis patients using bioimpedance spectroscopy. Kidney Int 1996; 49: 1105-1109
    • (1996) Kidney Int. , vol.49 , pp. 1105-1109
    • Fisch, B.J.1    Spiegel, D.M.2
  • 20
    • 0036377061 scopus 로고    scopus 로고
    • Adjusting dry weight by extracellular volume and body composition in hemodialysis patients
    • Chen YC, Chen HH, Yeh JC, Chen SY. Adjusting dry weight by extracellular volume and body composition in hemodialysis patients. Nephron 2002; 92: 91-96
    • (2002) Nephron , vol.92 , pp. 91-96
    • Chen, Y.C.1    Chen, H.H.2    Yeh, J.C.3    Chen, S.Y.4
  • 21
    • 0032893727 scopus 로고    scopus 로고
    • Fluid state and blood pressure control in patients treated with long and short haemodialysis
    • Katzarski KS, Charra B, Luik AJ et al. Fluid state and blood pressure control in patients treated with long and short haemodialysis. Nephrol Dial Transplant 1999; 14: 369-375
    • (1999) Nephrol. Dial. Transplant , vol.14 , pp. 369-375
    • Katzarski, K.S.1    Charra, B.2    Luik, A.J.3
  • 22
    • 0031970239 scopus 로고    scopus 로고
    • Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis
    • The Italian Hemodialysis-Bioelectrical Impedance Analysis (HD-BIA) Study Group
    • Piccoli A. Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis. The Italian Hemodialysis-Bioelectrical Impedance Analysis (HD-BIA) Study Group. Kidney Int 1998; 53: 1036-1043
    • (1998) Kidney Int. , vol.53 , pp. 1036-1043
    • Piccoli, A.1
  • 23
    • 0028048393 scopus 로고
    • A new method for monitoring body fluid variation by bioimpedance analysis: The RXc graph
    • Piccoli A, Rossi B, Pillon L, Bucciante G. A new method for monitoring body fluid variation by bioimpedance analysis: the RXc graph. Kidney Int 1994; 46: 534-539
    • (1994) Kidney Int. , vol.46 , pp. 534-539
    • Piccoli, A.1    Rossi, B.2    Pillon, L.3    Bucciante, G.4
  • 24
    • 0033831808 scopus 로고    scopus 로고
    • Comparison of vector and conventional bioelectrical impedance analysis in the optimal dry weight prescription in hemodialysis
    • Guida B, de Nicola L, Trio R et al. Comparison of vector and conventional bioelectrical impedance analysis in the optimal dry weight prescription in hemodialysis. Am J Nephrol 2000; 20: 311-318
    • (2000) Am. J. Nephrol. , vol.20 , pp. 311-318
    • Guida, B.1    de Nicola, L.2    Trio, R.3
  • 25
    • 0033972819 scopus 로고    scopus 로고
    • Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis
    • Spiegel DM, Bashir K, Fisch B. Bioimpedance resistance ratios for the evaluation of dry weight in hemodialysis. Clin Nephrol 2000; 53: 108-114
    • (2000) Clin. Nephrol. , vol.53 , pp. 108-114
    • Spiegel, D.M.1    Bashir, K.2    Fisch, B.3
  • 26
    • 0035162645 scopus 로고    scopus 로고
    • Preserving central blood volume: Changes in body fluid compartments during hemodialysis
    • Shulman T, Heidenheim AP, Kianfar C et al. Preserving central blood volume: changes in body fluid compartments during hemodialysis. ASAIO J 2001; 47: 615-618
    • (2001) ASAIO J. , vol.47 , pp. 615-618
    • Shulman, T.1    Heidenheim, A.P.2    Kianfar, C.3
  • 27
    • 0032796823 scopus 로고    scopus 로고
    • Optimizing electrode sites for segmental bioimpedance measurements
    • Cornish BH, Jacobs A, Thomas BJ, Ward LC. Optimizing electrode sites for segmental bioimpedance measurements. Physiol Meas 1999; 20: 241-250
    • (1999) Physiol. Meas. , vol.20 , pp. 241-250
    • Cornish, B.H.1    Jacobs, A.2    Thomas, B.J.3    Ward, L.C.4
  • 28
    • 0031807043 scopus 로고    scopus 로고
    • A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy
    • Scharfetter H, Hartinger P, Hinghofer-Szalkay H, Hutten H. A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy. Physiol Meas 1998; 19: 247-261
    • (1998) Physiol. Meas. , vol.19 , pp. 247-261
    • Scharfetter, H.1    Hartinger, P.2    Hinghofer-Szalkay, H.3    Hutten, H.4
  • 29
    • 0031105263 scopus 로고    scopus 로고
    • Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis
    • Scharfetter H, Wirnsberger GH, Holzer H, Hutten H. Influence of ionic shifts during dialysis on volume estimations with multifrequency impedance analysis. Med Biol Eng Comput 1997; 35: 96-102
    • (1997) Med. Biol. Eng. Comput. , vol.35 , pp. 96-102
    • Scharfetter, H.1    Wirnsberger, G.H.2    Holzer, H.3    Hutten, H.4
  • 30
    • 0033673488 scopus 로고    scopus 로고
    • Temperature-compensated bioimpedance system for estimating body composition
    • Huang JJ, Cheng KS, Peng CJ. Temperature-compensated bioimpedance system for estimating body composition. IEEE Eng Med Biol Mag 2000; 19: 66-73
    • (2000) IEEE Eng. Med. Biol. Mag. , vol.19 , pp. 66-73
    • Huang, J.J.1    Cheng, K.S.2    Peng, C.J.3
  • 31
    • 0032798252 scopus 로고    scopus 로고
    • Comparison of optical, electrical, and centrifugation techniques for haematocrit monitoring of dialysed patients
    • Jaffrin MY, Fournier C. Comparison of optical, electrical, and centrifugation techniques for haematocrit monitoring of dialysed patients. Med Biol Eng Comput 1999; 37: 433-439
    • (1999) Med. Biol. Eng. Comput. , vol.37 , pp. 433-439
    • Jaffrin, M.Y.1    Fournier, C.2
  • 33
    • 0032985057 scopus 로고    scopus 로고
    • Study of the relation between fluid distribution change in tissue and impedance change during hemodialysis by frequency characteristics of the flowing blood
    • Sakamoto K, Sunaga R, Nakamura K et al. Study of the relation between fluid distribution change in tissue and impedance change during hemodialysis by frequency characteristics of the flowing blood. Ann NY Acad Sci 1999; 873: 77-88
    • (1999) Ann. N.Y. Acad. Sci. , vol.873 , pp. 77-88
    • Sakamoto, K.1    Sunaga, R.2    Nakamura, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.