Volumn 20, Issue 2, 2004, Pages 336-339

Single-shot half-Fourier RARE sequence with ultra short inter-echo spacing for lung imaging

Author keywords

Half Fourier imaging; Lung; Magnetic resonance (MR); Pulse sequence; Rapid imaging

Indexed keywords

ADULT; ARTICLE; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGE ENHANCEMENT; IMAGE PROCESSING; IMAGE QUALITY; LUNG; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIOLOGICAL PARAMETERS; SIGNAL NOISE RATIO; SIGNAL PROCESSING; SINGLE SHOT HALF FOURIER RAPID ACQUISITION RELAXATION ENHANCEMENT; ULTRA SHORT INTER ECHO SPACING;

EID: 3242801268     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20107     Document Type: Article
Times cited : (19)

References (19)
  • 2
    • 0025853865 scopus 로고
    • Alveolar air-tissue interface and nuclear magnetic resonance behavior of lung
    • Cutillo AG, Ganesan K, Ailion DC, et al. Alveolar air-tissue interface and nuclear magnetic resonance behavior of lung. J Appl Physiol 1991;70:2145-2154.
    • (1991) J Appl Physiol , vol.70 , pp. 2145-2154
    • Cutillo, A.G.1    Ganesan, K.2    Ailion, D.C.3
  • 4
    • 0033013455 scopus 로고    scopus 로고
    • MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence
    • Hatabu H, Gaa J, Tadamura E, et al. MR imaging of pulmonary parenchyma with a half-Fourier single-shot turbo spin-echo (HASTE) sequence. Eur J Radiol 1999;29:152-159.
    • (1999) Eur J Radiol , vol.29 , pp. 152-159
    • Hatabu, H.1    Gaa, J.2    Tadamura, E.3
  • 5
    • 0025776030 scopus 로고
    • Lung parenchyma: Magnetic susceptibility in MR imaging
    • Bergin CJ, Glover GH, Pauly JM. Lung parenchyma: magnetic susceptibility in MR imaging. Radiology 1991;180:845-848.
    • (1991) Radiology , vol.180 , pp. 845-848
    • Bergin, C.J.1    Glover, G.H.2    Pauly, J.M.3
  • 6
    • 0025876984 scopus 로고
    • Lung parenchyma: Projection reconstruction MR imaging
    • Bergin CJ, Pauly JM, Macovski A. Lung parenchyma: projection reconstruction MR imaging. Radiology 1991;179:777-781.
    • (1991) Radiology , vol.179 , pp. 777-781
    • Bergin, C.J.1    Pauly, J.M.2    Macovski, A.3
  • 7
    • 0028910197 scopus 로고
    • Multi-slice, breathhold imaging of the lung with submillisecond echo times
    • Alsop DC, Hatabu H, Bonnet M, Listerud J, Gefter W. Multi-slice, breathhold imaging of the lung with submillisecond echo times. Magn Reson Med 1995;33:678-682.
    • (1995) Magn Reson Med , vol.33 , pp. 678-682
    • Alsop, D.C.1    Hatabu, H.2    Bonnet, M.3    Listerud, J.4    Gefter, W.5
  • 8
    • 0032587625 scopus 로고    scopus 로고
    • T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging
    • Hatabu H, Alsop DC, Listerud J, Bonnet M, Gefter WB. T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging. Eur J Radiol 1999;29:245-252.
    • (1999) Eur J Radiol , vol.29 , pp. 245-252
    • Hatabu, H.1    Alsop, D.C.2    Listerud, J.3    Bonnet, M.4    Gefter, W.B.5
  • 10
    • 0026460816 scopus 로고
    • MR imaging of the lungs: Value of short TE spin-echo pulse sequences
    • Mayo JR, MacKay A, Muller NL. MR imaging of the lungs: value of short TE spin-echo pulse sequences. AJR Am J Roentgenol 1992;159:951-956.
    • (1992) AJR Am J Roentgenol , vol.159 , pp. 951-956
    • Mayo, J.R.1    MacKay, A.2    Muller, N.L.3
  • 13
    • 0021254071 scopus 로고
    • NMR even echo rephasing in slow laminar flow
    • Waluch V, Bradley WG. NMR even echo rephasing in slow laminar flow. J Comput Assist Tomogr 1984;8:594-598.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 594-598
    • Waluch, V.1    Bradley, W.G.2
  • 14
    • 0028097780 scopus 로고
    • Metallic artifacts on MR images of the postoperative spine: Reduction with fast spin-echo techniques
    • Tartaglino LM, Flanders AE, Vinitski S, Friedman DP. Metallic artifacts on MR images of the postoperative spine: reduction with fast spin-echo techniques. Radiology 1994;190:565-569.
    • (1994) Radiology , vol.190 , pp. 565-569
    • Tartaglino, L.M.1    Flanders, A.E.2    Vinitski, S.3    Friedman, D.P.4
  • 15
    • 0026467251 scopus 로고
    • The loss of small objects in variable TE imaging: Implications for FSE, RARE, and EPI
    • Constable RT, Gore JC. The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn Reson Med 1992;28:9-24.
    • (1992) Magn Reson Med , vol.28 , pp. 9-24
    • Constable, R.T.1    Gore, J.C.2
  • 16
    • 0032948001 scopus 로고    scopus 로고
    • Improved visualization of the human lung in 1H MRI using multiple inversion recovery for simultaneous suppression of signal contributions from fat and muscle
    • Mai VM, Knight-Scott J, Berr SS. Improved visualization of the human lung in 1H MRI using multiple inversion recovery for simultaneous suppression of signal contributions from fat and muscle. Magn Reson Med 1999;41:866-870.
    • (1999) Magn Reson Med , vol.41 , pp. 866-870
    • Mai, V.M.1    Knight-Scott, J.2    Berr, S.S.3
  • 19
    • 0029925919 scopus 로고    scopus 로고
    • Coherence transfer by isotropic mixing in Carr-Purcell-Meiboom-Gill imaging: Implications for the bright fat phenomenon in fast spin-echo imaging
    • Williamson DS, Mulken RV, Jakab PD, Jolesz FA. Coherence transfer by isotropic mixing in Carr-Purcell-Meiboom-Gill imaging: implications for the bright fat phenomenon in fast spin-echo imaging. Magn Reson Med 1996;35:506-513.
    • (1996) Magn Reson Med , vol.35 , pp. 506-513
    • Williamson, D.S.1    Mulken, R.V.2    Jakab, P.D.3    Jolesz, F.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.