메뉴 건너뛰기




Volumn 20, Issue 2, 2004, Pages 321-326

Functional MRI using multiple receiver coils: BOLD signal changes and signal-to-noise ratio for three-dimensional-PRESTO vs. single shot EPI in comparison to a standard quadrature head coil

Author keywords

BOLD; Functional magnetic resonance imaging; Intraoperative imaging; Phased array; Signal to noise; Stereotaxy; Techniques

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; ECHO PLANAR IMAGING; HUMAN; HUMAN EXPERIMENT; IMAGE PROCESSING; IMAGE QUALITY; INTERMETHOD COMPARISON; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; OXYGEN BLOOD LEVEL; PRIORITY JOURNAL; RADIOLOGICAL PARAMETERS; SIGNAL NOISE RATIO; SIGNAL PROCESSING; SINGLE SHOT ECHO PLANAR IMAGING; THREE DIMENSIONAL IMAGING;

EID: 3242800441     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.20101     Document Type: Article
Times cited : (7)

References (14)
  • 1
    • 0032748010 scopus 로고    scopus 로고
    • Interventional MR imaging: Concepts, systems and applications in Neuroradiology
    • Lewin JS. Interventional MR imaging: concepts, systems and applications in Neuroradiology. AJNR Am J Roentgenol 1999;20:735-748.
    • (1999) AJNR Am J Roentgenol , vol.20 , pp. 735-748
    • Lewin, J.S.1
  • 3
    • 3242746264 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging during deep brain stimulation: A pilot study in four patients with Parkinson's Disease
    • Hesselmann V, Sorger B, Gimus R, et al. Functional magnetic resonance imaging during deep brain stimulation: a pilot study in four patients with Parkinson's Disease. European Radiology. 2004;14:931-937.
    • (2004) European Radiology , vol.14 , pp. 931-937
    • Hesselmann, V.1    Sorger, B.2    Gimus, R.3
  • 4
    • 0035515589 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging during deep brain stimulation: A pilot study in four patients with Parkinson's disease
    • Jech R. Urgosik D, Tintera J. et al. Functional magnetic resonance imaging during deep brain stimulation: a pilot study in four patients with Parkinson's disease. Mov Disord 2001;16:1126-1132.
    • (2001) Mov Disord , vol.16 , pp. 1126-1132
    • Jech, R.1    Urgosik, D.2    Tintera, J.3
  • 5
    • 0030455308 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging in a stereotactical setup
    • Debus J, Essig M, Schad LR, et al. Functional magnetic resonance imaging in a stereotactical setup. Magn Reson Imaging 1996;14:1007-1012.
    • (1996) Magn Reson Imaging , vol.14 , pp. 1007-1012
    • Debus, J.1    Essig, M.2    Schad, L.R.3
  • 7
    • 0031974331 scopus 로고    scopus 로고
    • A novel multi-segment surface coil for neurofunctional magnetic resonance imaging
    • Lin CS, Rajan SS, Gold J. A novel multi-segment surface coil for neurofunctional magnetic resonance imaging. Magn Reson Med 1998;39:164-168.
    • (1998) Magn Reson Med , vol.39 , pp. 164-168
    • Lin, C.S.1    Rajan, S.S.2    Gold, J.3
  • 8
    • 0027319232 scopus 로고
    • Fast echo-shifted gradient recalled MRI: Combining a short repetition time with variable T2* imaging
    • Liu G, Sobering G, Olson AW, van Gelderen P, Moonen CT. Fast echo-shifted gradient recalled MRI: combining a short repetition time with variable T2* imaging. Magn Reson Med 1993:30:68-75.
    • (1993) Magn Reson Med , vol.30 , pp. 68-75
    • Liu, G.1    Sobering, G.2    Olson, A.W.3    Van Gelderen, P.4    Moonen, C.T.5
  • 9
    • 0029112443 scopus 로고
    • Three dimensional functional magnetic resonance imaging of human brain on a clinical 1.5 Tesla scanner
    • Van Gelderen P, Ramsey NF, Liu G, et al. Three dimensional functional magnetic resonance imaging of human brain on a clinical 1.5 Tesla scanner. Proc Natl Acad Sci U S A 1995;92:6906-6910.
    • (1995) Proc Natl Acad Sci U S A , vol.92 , pp. 6906-6910
    • Van Gelderen, P.1    Ramsey, N.F.2    Liu, G.3
  • 11
    • 0032189299 scopus 로고    scopus 로고
    • Phase navigator correction in 3D fMRI improves detection of brain activation: Quantitative assessment with a graded motor activation procedure
    • Ramsey NF, van den Brink AMC. van Muiswinkel PJM, et al. Phase navigator correction in 3D fMRI improves detection of brain activation: quantitative assessment with a graded motor activation procedure. Neuroimage 1998;8:240-248.
    • (1998) Neuroimage , vol.8 , pp. 240-248
    • Ramsey, N.F.1    Van Den Brink, A.M.C.2    Van Muiswinkel, P.J.M.3
  • 13
    • 3242749309 scopus 로고    scopus 로고
    • Optimal efficiency of 3D and 2D BOLD gradient echo fMRI methods
    • Moonen CTW, Bandettini PA, editors. Berlin, Heidelberg, New York: Springer
    • Moonen CTW, van Gelderen P. Optimal efficiency of 3D and 2D BOLD gradient echo fMRI methods. In: Moonen CTW, Bandettini PA, editors. Functional MRI. Berlin, Heidelberg, New York: Springer; 1999, p 137-148.
    • (1999) Functional MRI , pp. 137-148
    • Moonen, C.T.W.1    Van Gelderen, P.2
  • 14
    • 0034089499 scopus 로고    scopus 로고
    • PRESTO-Sense: An ultrafast whole-brain imaging fMRI technique
    • Golay X, Pruessmann KL, Weiger M, et al. PRESTO-Sense: an ultrafast whole-brain imaging fMRI technique. Magn Reson Med 2000;43:779-786.
    • (2000) Magn Reson Med , vol.43 , pp. 779-786
    • Golay, X.1    Pruessmann, K.L.2    Weiger, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.