메뉴 건너뛰기




Volumn 27, Issue 7, 2004, Pages 965-970

Cooled intramural needle catheter ablation creates deeper lesions than irrigated tip catheter ablation

Author keywords

Ablation; Arrhythmia; Catheterization; Electrophysiology

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BLOOD OXYGENATION; CATHETER; CATHETER ABLATION; COOLED INTRAMURAL NEEDLE CATHETER ABLATION; DEVICE; ELECTRODE; HEART CATHETERIZATION; HEART INJURY; HEART MUSCLE; HEART PERFUSION; HEART SURGERY; INTERMETHOD COMPARISON; IRRIGATED TIP CATHETER ABLATION; MALE; NONHUMAN; SHEEP; STATISTICAL SIGNIFICANCE; TEMPERATURE MEASUREMENT; TIME;

EID: 3242772146     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2004.00566.x     Document Type: Article
Times cited : (12)

References (17)
  • 1
    • 0025906317 scopus 로고
    • Functional role of the epicardium in postinfarction ventricular tachycardia
    • Littmann L, Svenson RH, Gallagher JJ, et al. Functional role of the epicardium in postinfarction ventricular tachycardia. Circulation 1991; 83:1577-1591.
    • (1991) Circulation , vol.83 , pp. 1577-1591
    • Littmann, L.1    Svenson, R.H.2    Gallagher, J.J.3
  • 2
    • 0032903237 scopus 로고    scopus 로고
    • Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: Impact of ablation site, electrode size, and convective cooling
    • Hogh Petersen H, Chen X, Pietersen A, et al. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: Impact of ablation site, electrode size, and convective cooling. Circulation 1999; 99:319-325.
    • (1999) Circulation , vol.99 , pp. 319-325
    • Hogh Petersen, H.1    Chen, X.2    Pietersen, A.3
  • 3
    • 0025293526 scopus 로고
    • Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model
    • Haines DE, Watson DD, Verow AF. Electrode radius predicts lesion radius during radiofrequency energy heating. Validation of a proposed thermodynamic model. Circ Res 1990; 67:124-129.
    • (1990) Circ Res , vol.67 , pp. 124-129
    • Haines, D.E.1    Watson, D.D.2    Verow, A.F.3
  • 4
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • Nakagawa H, Yamanashi WS, Pitha JV, et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995; 91:2264-2273.
    • (1995) Circulation , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3
  • 5
    • 0029559129 scopus 로고
    • Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart
    • Ruffy R, Mir AI, Santel DJ, et al. Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the ovine heart. J Cardiovasc Electrophysiol 1995; 6:1089-1096.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 1089-1096
    • Ruffy, R.1    Mir, A.I.2    Santel, D.J.3
  • 6
    • 0028075999 scopus 로고
    • Development of a new intraoperative radiofrequency ablation technique using a needle electrode
    • Ohtake H, Misaki T, Matsunaga Y, et al. Development of a new intraoperative radiofrequency ablation technique using a needle electrode. Ann Thorac Surg 1994; 58:750-753.
    • (1994) Ann Thorac Surg , vol.58 , pp. 750-753
    • Ohtake, H.1    Misaki, T.2    Matsunaga, Y.3
  • 7
    • 0242636809 scopus 로고    scopus 로고
    • Catheter intramural needle radiofrequency ablation creates deeper lesions than irrigated tip catheter ablation
    • Thiagalingam A, Campbell CR, Boyd AC, et al. Catheter intramural needle radiofrequency ablation creates deeper lesions than irrigated tip catheter ablation. PACE 2003; 26:1-5.
    • (2003) PACE , vol.26 , pp. 1-5
    • Thiagalingam, A.1    Campbell, C.R.2    Boyd, A.C.3
  • 8
    • 0033982515 scopus 로고    scopus 로고
    • A new catheter design using needle electrode for subendocardial RF ablation of ventricular muscles: Finite element analysis and in vitro experiments
    • Woo EJ, Tungjitkusolmun S, Cao H, et al. A new catheter design using needle electrode for subendocardial RF ablation of ventricular muscles: Finite element analysis and in vitro experiments. IEEE Trans Biomed Eng 2000; 47:23-31.
    • (2000) IEEE Trans Biomed Eng , vol.47 , pp. 23-31
    • Woo, E.J.1    Tungjitkusolmun, S.2    Cao, H.3
  • 9
    • 0030187101 scopus 로고    scopus 로고
    • A cooled needle electrode for radiofrequency tissue ablation: Thermodynamic aspects of improved performance compared with conventional needle design
    • Lorentzen T. A cooled needle electrode for radiofrequency tissue ablation: Thermodynamic aspects of improved performance compared with conventional needle design. Acad Radiol 1996; 3:556-563.
    • (1996) Acad Radiol , vol.3 , pp. 556-563
    • Lorentzen, T.1
  • 10
    • 0342470431 scopus 로고    scopus 로고
    • Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter
    • Jais P, Shah DC, Haissaguerre M, et al. Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter. Circulation 2000; 101:772-776.
    • (2000) Circulation , vol.101 , pp. 772-776
    • Jais, P.1    Shah, D.C.2    Haissaguerre, M.3
  • 11
    • 0024363035 scopus 로고
    • The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro
    • Blouin LT, Marcus FI. The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro. PACE 1989; 12:136-143.
    • (1989) PACE , vol.12 , pp. 136-143
    • Blouin, L.T.1    Marcus, F.I.2
  • 12
    • 3242798008 scopus 로고    scopus 로고
    • Deep radiofrequency lesions can be created with a retractable needle-tipped catheter
    • Sapp J, Cooper J, Sorrel T, et al. Deep radiofrequency lesions can be created with a retractable needle-tipped catheter. PACE 2002; 24:523.
    • (2002) PACE , vol.24 , pp. 523
    • Sapp, J.1    Cooper, J.2    Sorrel, T.3
  • 13
    • 0036630132 scopus 로고    scopus 로고
    • Left ventricular catheter ablation using direct, intramural ethanol injection in swine
    • Callans DJ, Ren JF, Narula N, et al. Left ventricular catheter ablation using direct, intramural ethanol injection in swine. J Interv Card Electrophysiol 2002; 6:225-231.
    • (2002) J Interv Card Electrophysiol , vol.6 , pp. 225-231
    • Callans, D.J.1    Ren, J.F.2    Narula, N.3
  • 14
    • 0034065874 scopus 로고    scopus 로고
    • Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation
    • VanderBrink BA, Gilbride C, Aronovitz MJ, et al. Safety and efficacy of a steerable temperature monitoring microwave catheter system for ventricular myocardial ablation. J Cardiovasc Electrophysiol 2000; 11:305-310.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 305-310
    • VanderBrink, B.A.1    Gilbride, C.2    Aronovitz, M.J.3
  • 15
    • 0033956518 scopus 로고    scopus 로고
    • Popping phenomena in temperature-controlled radiofrequency ablation: When and why do they occur?
    • Eick OJ, Gerritse B, Schumacher B. Popping phenomena in temperature-controlled radiofrequency ablation: When and why do they occur? PACE 2000; 23:253-258.
    • (2000) PACE , vol.23 , pp. 253-258
    • Eick, O.J.1    Gerritse, B.2    Schumacher, B.3
  • 16
    • 0027316390 scopus 로고
    • The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring
    • Haines D. The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring. PACE 1993; 16:586-591.
    • (1993) PACE , vol.16 , pp. 586-591
    • Haines, D.1
  • 17
    • 0034696530 scopus 로고    scopus 로고
    • Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy
    • Marchlinski FE, Callans DJ, Gottlieb CD, et al. Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. Circulation 2000; 101:1288-1296.
    • (2000) Circulation , vol.101 , pp. 1288-1296
    • Marchlinski, F.E.1    Callans, D.J.2    Gottlieb, C.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.