메뉴 건너뛰기




Volumn 26, Issue 7, 2004, Pages 595-603

Development of a cost-effective loading machine for biomechanical evaluation of mouse transgenic models

Author keywords

Loading machine; Mechanical testing; Mouse; Tibia; Transgenics

Indexed keywords

MOLECULAR BIOLOGY; ORTHOPEDICS; PHYSIOLOGICAL MODELS;

EID: 3242734928     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2004.04.005     Document Type: Article
Times cited : (15)

References (8)
  • 2
    • 0036179760 scopus 로고    scopus 로고
    • Noninvasive loading of the murine tibia: An in vivo model for the study of mechanotransduction
    • Gross T.S., Srinivasan S., Liu C.C., Clemens T.L., Bain S.D. Noninvasive loading of the murine tibia: an in vivo model for the study of mechanotransduction. J Bone Miner Res. 17:(3):2002;493-501
    • (2002) J Bone Miner Res , vol.17 , Issue.3 , pp. 493-501
    • Gross, T.S.1    Srinivasan, S.2    Liu, C.C.3    Clemens, T.L.4    Bain, S.D.5
  • 3
    • 0036862205 scopus 로고    scopus 로고
    • Mechanotransduction in bone: Genetic effects on mechanosensitivity in mice
    • Robling A.G., Turner C.H. Mechanotransduction in bone: genetic effects on mechanosensitivity in mice. Bone. 31:(5):2002;562-569
    • (2002) Bone , vol.31 , Issue.5 , pp. 562-569
    • Robling, A.G.1    Turner, C.H.2
  • 5
    • 0141565387 scopus 로고    scopus 로고
    • A novel technique for four-point bending of small bone samples with semi-automatic analysis
    • Draper ERC, Goodship AE. A novel technique for four-point bending of small bone samples with semi-automatic analysis. J Biomech 2003;36(10):1497-502.
    • (2003) J Biomech , vol.36 , Issue.10 , pp. 1497-1502
    • Draper, E.R.C.1    Goodship, A.E.2
  • 6
    • 0346333123 scopus 로고    scopus 로고
    • The effect of COX-2 specific inhibitors on fracture healing in the adult rat femur
    • Huang-Brown K.M., Saunders M.M., Kirsch T., Donahue H.J., Reid J.S. The effect of COX-2 specific inhibitors on fracture healing in the adult rat femur. JBJS Am. 86-A:(1):2004;116-123
    • (2004) JBJS Am , vol.86 , Issue.1 , pp. 116-123
    • Huang-Brown, K.M.1    Saunders, M.M.2    Kirsch, T.3    Donahue, H.J.4    Reid, J.S.5
  • 7
    • 0034506952 scopus 로고    scopus 로고
    • Torsional evaluation of femoral allograft fixation: A comparison of plates to intramedullary nails
    • Saunders MM, Kaag M, Jacobs CJ, Parrish WM. Torsional evaluation of femoral allograft fixation: A comparison of plates to intramedullary nails. Trans BMES Ann Mtg 2000;S1(28):S10.
    • (2000) Trans BMES Ann Mtg , vol.S1 , Issue.28
    • Saunders, M.M.1    Kaag, M.2    Jacobs, C.J.3    Parrish, W.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.