메뉴 건너뛰기




Volumn 26, Issue 6, 2004, Pages 449-458

Implementation of natural sensory feedback in a portable control system for a hand grasp neuroprosthesis

Author keywords

Functional electrical stimulation; Portable system; Sensory feedback

Indexed keywords

BAND-PASS FILTER; INDEX FINGER; NEUROPROSTHESIS;

EID: 3242684479     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2004.03.003     Document Type: Article
Times cited : (35)

References (36)
  • 1
    • 0024116453 scopus 로고
    • A flexible, portable system for neuromuscular stimulation in the paralyzed upper extremity
    • Buckett J.R., Peckham P.H., Thrope G.B., Braswell S.D., Keith M.W. A flexible, portable system for neuromuscular stimulation in the paralyzed upper extremity. IEEE Trans Biomed Eng. 35:(11):1988;897-904
    • (1988) IEEE Trans Biomed Eng , vol.35 , Issue.11 , pp. 897-904
    • Buckett, J.R.1    Peckham, P.H.2    Thrope, G.B.3    Braswell, S.D.4    Keith, M.W.5
  • 2
    • 0000168558 scopus 로고
    • A portable multi-channel FES system for restoration of motor function of the paralyzed extremities
    • Handa Y., Ohkubo K., Hoshimiya N. A portable multi-channel FES system for restoration of motor function of the paralyzed extremities. Automedica. 11:1989;221-231
    • (1989) Automedica , vol.11 , pp. 221-231
    • Handa, Y.1    Ohkubo, K.2    Hoshimiya, N.3
  • 3
    • 0025254291 scopus 로고
    • Upper limb functions regained in quadriplegia: A hybrid computerized neuromuscular stimulation system
    • Nathan R.H., Ohry A. Upper limb functions regained in quadriplegia: a hybrid computerized neuromuscular stimulation system. Arch Phys Med Rehabil. 71:(6):1990;415-421
    • (1990) Arch Phys Med Rehabil , vol.71 , Issue.6 , pp. 415-421
    • Nathan, R.H.1    Ohry, A.2
  • 4
    • 0030924758 scopus 로고    scopus 로고
    • The bionic glove: An electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia
    • Prochazka A., Gauthier M., Wieler M., Kenwell Z. The bionic glove: an electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia. Arch Phys Med Rehabil. 78:(6):1997;608-614
    • (1997) Arch Phys Med Rehabil , vol.78 , Issue.6 , pp. 608-614
    • Prochazka, A.1    Gauthier, M.2    Wieler, M.3    Kenwell, Z.4
  • 6
    • 3242732017 scopus 로고
    • Artificial sensors suitable for closed-loop control of FNS
    • R.B. Stein, P.H. Peckham, & D.B. Popovic. New York, NY: Oxford University Press
    • Webster J.G. Artificial sensors suitable for closed-loop control of FNS. Stein R.B., Peckham P.H., Popovic D.B. Neural prostheses: replacing motor function after disease or disability. 1992;88-98 Oxford University Press, New York, NY
    • (1992) Neural Prostheses: Replacing Motor Function after Disease or Disability , pp. 88-98
    • Webster, J.G.1
  • 7
    • 0033016663 scopus 로고    scopus 로고
    • Control of FES thumb forces using slip information obtained from cutaneous electroneurogram in quadriplegic man
    • Haugland M., Lickel A., Haase J., Sinkjær T. Control of FES thumb forces using slip information obtained from cutaneous electroneurogram in quadriplegic man. IEEE Trans Rehab Eng. 7:(2):1999;215-227
    • (1999) IEEE Trans Rehab Eng , vol.7 , Issue.2 , pp. 215-227
    • Haugland, M.1    Lickel, A.2    Haase, J.3    Sinkjær, T.4
  • 10
    • 0002797562 scopus 로고
    • Techniques to study spinal-cord, peripheral nerve, and muscle activity in freely moving animals
    • A.A. Boulton, G.B. Baker, & C.H. Vanderwolf. Clifton, NJ: Humana Press
    • Hoffer J.A. Techniques to study spinal-cord, peripheral nerve, and muscle activity in freely moving animals. Boulton A.A., Baker G.B., Vanderwolf C.H. Neurophysiological techniques: applications to neural systems. 1990;65-145 Humana Press, Clifton, NJ
    • (1990) Neurophysiological Techniques: Applications to Neural Systems , pp. 65-145
    • Hoffer, J.A.1
  • 12
    • 0028385985 scopus 로고
    • Slip information provided by nerve cuff signals: Application in closed-loop control of functional electrical stimulation
    • Haugland M.K., Hoffer J.A. Slip information provided by nerve cuff signals: application in closed-loop control of functional electrical stimulation. IEEE Trans Rehab Eng. 2:(1):1994;29-36
    • (1994) IEEE Trans Rehab Eng , vol.2 , Issue.1 , pp. 29-36
    • Haugland, M.K.1    Hoffer, J.A.2
  • 13
    • 0028386171 scopus 로고
    • Skin contact force information in sensory nerve signals recorded by implanted cuff electrodes
    • Haugland M.K., Hoffer J.A., Sinkjær T. Skin contact force information in sensory nerve signals recorded by implanted cuff electrodes. IEEE Trans Rehab Eng. 2:(1):1994;18-28
    • (1994) IEEE Trans Rehab Eng , vol.2 , Issue.1 , pp. 18-28
    • Haugland, M.K.1    Hoffer, J.A.2    Sinkjær, T.3
  • 15
    • 0344157831 scopus 로고    scopus 로고
    • A portable system for closed loop control of the paralysed hand using functional electrical stimulation
    • Crook S.E., Chappell P.H. A portable system for closed loop control of the paralysed hand using functional electrical stimulation. Med Eng Phys. 20:(1):1998;70-76
    • (1998) Med Eng Phys , vol.20 , Issue.1 , pp. 70-76
    • Crook, S.E.1    Chappell, P.H.2
  • 16
    • 0028746879 scopus 로고
    • A programmable electronic stimulator for FES systems
    • Ilic M., Vasiljevic D., Popovic D. A programmable electronic stimulator for FES systems. IEEE Trans Biomed Eng. 2:(4):1994;234-239
    • (1994) IEEE Trans Biomed Eng , vol.2 , Issue.4 , pp. 234-239
    • Ilic, M.1    Vasiljevic, D.2    Popovic, D.3
  • 17
    • 0023378409 scopus 로고
    • An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle
    • Smith B., Peckham P.H., Keith M.W., Roscoe D.D. An externally powered, multichannel, implantable stimulator for versatile control of paralyzed muscle. IEEE Trans Biomed Eng. 34:(7):1987;499-508
    • (1987) IEEE Trans Biomed Eng , vol.34 , Issue.7 , pp. 499-508
    • Smith, B.1    Peckham, P.H.2    Keith, M.W.3    Roscoe, D.D.4
  • 21
    • 0028385607 scopus 로고
    • Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles
    • Haugland M.K., Hoffer J.A. Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles. IEEE Trans Rehab Eng. 2:(1):1994;37-39
    • (1994) IEEE Trans Rehab Eng , vol.2 , Issue.1 , pp. 37-39
    • Haugland, M.K.1    Hoffer, J.A.2
  • 22
    • 0032102982 scopus 로고    scopus 로고
    • Digital signal processing algorithms for the detection of afferent nerve activity recorded from cuff electrodes
    • Upshaw B., Sinkjær T. Digital signal processing algorithms for the detection of afferent nerve activity recorded from cuff electrodes. IEEE Trans Rehabil Eng. 6:(2):1998;172-181
    • (1998) IEEE Trans Rehabil Eng , vol.6 , Issue.2 , pp. 172-181
    • Upshaw, B.1    Sinkjær, T.2
  • 25
    • 3242703925 scopus 로고    scopus 로고
    • Closed-loop control of an FES system incorporating natural sensory feedback used for restoration of hand grasp in tetraplegics
    • Inmann A., Haugland M. Closed-loop control of an FES system incorporating natural sensory feedback used for restoration of hand grasp in tetraplegics. Proceedings of the IFESS 4th Annual Conference 1999; Sendai, Japan:1999;77-80
    • (1999) Proceedings of the IFESS 4th Annual Conference 1999; Sendai, Japan , pp. 77-80
    • Inmann, A.1    Haugland, M.2
  • 26
    • 0022218918 scopus 로고
    • A voice-controlled functional electrical stimulation system for the paralyzed hand
    • Handa Y., Handa T., Nakatsuchi Y., Yagi R., Hoshimiya N. A voice-controlled functional electrical stimulation system for the paralyzed hand. Jap J Rehabil Med. 23:(5):1985;292-298
    • (1985) Jap J Rehabil Med , vol.23 , Issue.5 , pp. 292-298
    • Handa, Y.1    Handa, T.2    Nakatsuchi, Y.3    Yagi, R.4    Hoshimiya, N.5
  • 27
    • 3242730198 scopus 로고
    • A two-axis shoulder position transducer for control of orthotic/prosthetic devices
    • Bayer D.M., Lord R.H., Swanker J.W., Mortimer J.T. A two-axis shoulder position transducer for control of orthotic/prosthetic devices. IEEE Trans IECI. IECI-19:(2):1972;61-64
    • (1972) IEEE Trans IECI , vol.19 , Issue.2 , pp. 61-64
    • Bayer, D.M.1    Lord, R.H.2    Swanker, J.W.3    Mortimer, J.T.4
  • 28
    • 0025484695 scopus 로고
    • Evaluation of shoulder movement as a command control source
    • Johnson M.W., Peckham P.H. Evaluation of shoulder movement as a command control source. IEEE Trans Biomed Eng. 37:(9):1990;876-885
    • (1990) IEEE Trans Biomed Eng , vol.37 , Issue.9 , pp. 876-885
    • Johnson, M.W.1    Peckham, P.H.2
  • 29
    • 0032103958 scopus 로고    scopus 로고
    • A comparison between control methods for implanted FES hand-grasp systems
    • Hart R.L., Kilgore K.L., Peckham P.H. A comparison between control methods for implanted FES hand-grasp systems. IEEE Trans Rehab Eng. 6:(2):1998;208-218
    • (1998) IEEE Trans Rehab Eng , vol.6 , Issue.2 , pp. 208-218
    • Hart, R.L.1    Kilgore, K.L.2    Peckham, P.H.3
  • 30
    • 0024693347 scopus 로고
    • A multichannel FES system for the restoration of motor functions in high spinal cord injury patients: A respiration-controlled system for multijoint upper extremity
    • Hoshimiya N., Naito A., Yajima M., Handa Y. A multichannel FES system for the restoration of motor functions in high spinal cord injury patients: a respiration-controlled system for multijoint upper extremity. IEEE Trans Biomed Eng. 36:(7):1989;754-760
    • (1989) IEEE Trans Biomed Eng , vol.36 , Issue.7 , pp. 754-760
    • Hoshimiya, N.1    Naito, A.2    Yajima, M.3    Handa, Y.4
  • 31
    • 0022765174 scopus 로고
    • The myoelectric signal of electrically stimulated muscle during recruitment: An inherent feedback parameter for a closed-loop control scheme
    • Solomonow M., Baratta R., Shoji H., D'Ambrosia R.D. The myoelectric signal of electrically stimulated muscle during recruitment: an inherent feedback parameter for a closed-loop control scheme. IEEE Trans Biomed Eng. 33:(8):1986;735-745
    • (1986) IEEE Trans Biomed Eng , vol.33 , Issue.8 , pp. 735-745
    • Solomonow, M.1    Baratta, R.2    Shoji, H.3    D'Ambrosia, R.D.4
  • 32
    • 0030477159 scopus 로고    scopus 로고
    • Tri-state myoelectric control of bilateral upper extremity neuroprostheses for tetraplegic individuals
    • Scott T.R., Peckham P.H., Kilgore K.L. Tri-state myoelectric control of bilateral upper extremity neuroprostheses for tetraplegic individuals. IEEE Trans Rehabil Eng. 4:(4):1996;251-263
    • (1996) IEEE Trans Rehabil Eng , vol.4 , Issue.4 , pp. 251-263
    • Scott, T.R.1    Peckham, P.H.2    Kilgore, K.L.3
  • 33
    • 0033519550 scopus 로고    scopus 로고
    • EEG-based control of a hand grasp neuroprosthesis
    • Lauer R.T., Peckham P.H., Kilgore K.L. EEG-based control of a hand grasp neuroprosthesis. Neuroreport. 10:(8):1999;1767-1771
    • (1999) Neuroreport , vol.10 , Issue.8 , pp. 1767-1771
    • Lauer, R.T.1    Peckham, P.H.2    Kilgore, K.L.3
  • 34
    • 0028512470 scopus 로고
    • Instrumented assessment of FNS hand control during specific manipulation tasks
    • Burelbach J.C., Crago P.E. Instrumented assessment of FNS hand control during specific manipulation tasks. IEEE Trans Rehab Eng. 2:(3):1994;165-176
    • (1994) IEEE Trans Rehab Eng , vol.2 , Issue.3 , pp. 165-176
    • Burelbach, J.C.1    Crago, P.E.2
  • 36
    • 0036159631 scopus 로고    scopus 로고
    • Real time foot drop correction using machine learning and natural sensors
    • Hansen M, Haugland M, Sinkjær T, Donaldson N. Real time foot drop correction using machine learning and natural sensors. Neuromodulation 2002;5(1):41-53.
    • (2002) Neuromodulation , vol.5 , Issue.1 , pp. 41-53
    • Hansen, M.1    Haugland, M.2    Sinkjær, T.3    Donaldson, N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.