메뉴 건너뛰기




Volumn 346, Issue 1, 2004, Pages 13-18

Integration of data derived from biological variation into the quality management system

Author keywords

Analytical process; Biological variation; Postanalytical process; Preanalytical process; Quality system

Indexed keywords

ANALYTIC METHOD; CLINICAL LABORATORY; CONFERENCE PAPER; LABORATORY; LABORATORY TEST; MANAGEMENT; PRIORITY JOURNAL; QUALITY CONTROL; SAMPLING; VALIDATION PROCESS;

EID: 3242657426     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cccn.2004.03.022     Document Type: Conference Paper
Times cited : (10)

References (17)
  • 1
    • 0033369894 scopus 로고    scopus 로고
    • Current databases on biological variation: Pros, cons and progress
    • [Also available in
    • Ricós C., Alvarez V., Cava F., Garcia-Lario J.V., et al. Current databases on biological variation: pros, cons and progress. Scand. J. Clin. Lab. Invest. 59:1999;491-500. [Also available in http://www.westgard.com/ biodatabase1.htm]
    • (1999) Scand. J. Clin. Lab. Invest. , vol.59 , pp. 491-500
    • Ricós, C.1    Alvarez, V.2    Cava, F.3    Garcia-Lario, J.V.4
  • 2
    • 0028353805 scopus 로고
    • Biological variation in urine samples used for analyte measurements
    • Ricós C., Jiménez C.V., Hernández A., Simón M., et al. Biological variation in urine samples used for analyte measurements. Clin. Chem. 40:1994;472-477
    • (1994) Clin. Chem. , vol.40 , pp. 472-477
    • Ricós, C.1    Jiménez, C.V.2    Hernández, A.3    Simón, M.4
  • 3
    • 26144445519 scopus 로고    scopus 로고
    • Importance of preanalytical variables in defining quality specifications for total random and systematic variations. Oral communication. Euromedlab; 2001
    • Prague.
    • Ricós C, Hyltoft Petersen P. Importance of preanalytical variables in defining quality specifications for total random and systematic variations. Oral communication. Euromedlab; 2001. Scientific Workshop on Preanalytivcal Quality. Prague.
    • Scientific Workshop on Preanalytivcal Quality
    • Ricós, C.1    Hyltoft Petersen, P.2
  • 4
    • 0023612416 scopus 로고
    • Deciding the optimum interval between specimen collections: Theory and nomograms
    • Fraser C.G., Browning M.C.K. Deciding the optimum interval between specimen collections: theory and nomograms. Clin. Chem. 33:1987;1436-1438
    • (1987) Clin. Chem. , vol.33 , pp. 1436-1438
    • Fraser, C.G.1    Browning, M.C.K.2
  • 5
    • 3242676042 scopus 로고
    • Iso Guide 30 Terms and Definitions Used in Connection with Reference Materials
    • Geneva, Switzerland: ISO General Secretariat
    • ISO Guide 30 Terms and Definitions Used in Connection with Reference Materials. 2nd ed.:1992;ISO General Secretariat, Geneva, Switzerland
    • (1992) 2nd Ed.
  • 6
    • 3242741929 scopus 로고    scopus 로고
    • Samples: From the Patient to the Laboratory
    • Darmstadt: Git Verlag
    • Guder W.G., Narayanan S., Wisser H., Zawta B. Samples: from the Patient to the Laboratory. 2nd ed.:2001;Git Verlag, Darmstadt
    • (2001) 2nd Ed.
    • Guder, W.G.1    Narayanan, S.2    Wisser, H.3    Zawta, B.4
  • 9
    • 3242661732 scopus 로고
    • Patient preparation and specimen handling
    • College of American Pathologists (CAP) Patient preparation and specimen handling. Fascicle. VI:1992
    • (1992) Fascicle , vol.6
  • 10
    • 3242704049 scopus 로고    scopus 로고
    • Reference guide for diagnostic molecular pathology 7 flow cytometry. Patient preparation and specimen handling
    • College of American Pathologists (CAP) Reference guide for diagnostic molecular pathology 7 flow cytometry. Patient preparation and specimen handling. Fascicle. VII:1996
    • (1996) Fascicle , vol.7
  • 11
    • 3242689693 scopus 로고
    • Clinical laboratory handbook for patient preparation and specimen handling
    • Northfield, IL: College of American Pathologists
    • College of American Pathologists (CAP) Clinical laboratory handbook for patient preparation and specimen handling. Supplement for physician office laboratories. 1993;College of American Pathologists, Northfield, IL
    • (1993) Supplement for Physician Office Laboratories
  • 12
    • 0036827338 scopus 로고    scopus 로고
    • Biological variation data are necessary prerequisites for objective autoverification of clinical laboratory data
    • Fraser C.G., Stevenson H.P., Kennedy I.M.G. Biological variation data are necessary prerequisites for objective autoverification of clinical laboratory data. Accredit. Qual. Assur. 7:2002;455-460
    • (2002) Accredit. Qual. Assur. , vol.7 , pp. 455-460
    • Fraser, C.G.1    Stevenson, H.P.2    Kennedy, I.M.G.3
  • 13
    • 0020680638 scopus 로고
    • On the calculation of a reference change for comparing two consecutive measurements
    • Harris E.K., Yasaka T. On the calculation of a reference change for comparing two consecutive measurements. Clin. Chem. 29:1983;25-32
    • (1983) Clin. Chem. , vol.29 , pp. 25-32
    • Harris, E.K.1    Yasaka, T.2
  • 14
    • 3042605500 scopus 로고
    • Métodos de detección del error extra-analítico
    • Ricós C., Andreu A. Métodos de detección del error extra-analítico. Rev. Diagn. Biol. 37:1988;269-271
    • (1988) Rev. Diagn. Biol. , vol.37 , pp. 269-271
    • Ricós, C.1    Andreu, A.2
  • 15
    • 0030665102 scopus 로고    scopus 로고
    • A model for establishing biological variation in non-healthy situations: Renal post-transplantation data
    • Biosca C., Ricós C., Jiménez C.V., Lauzurica R., Galimany R. A model for establishing biological variation in non-healthy situations: renal post-transplantation data. Clin. Chem. 43:1997;2206-2208
    • (1997) Clin. Chem. , vol.43 , pp. 2206-2208
    • Biosca, C.1    Ricós, C.2    Jiménez, C.V.3    Lauzurica, R.4    Galimany, R.5
  • 16
    • 0033804629 scopus 로고    scopus 로고
    • Are equally spaced specimen collections necessary to assess biological variation? Evidence from renal transplant recipients
    • Biosca C., Ricós C., Jiménez C.V., Lauzurica R., Galimany R. Are equally spaced specimen collections necessary to assess biological variation? Evidence from renal transplant recipients. Clin. Chim. Acta. 30:2000;79-85
    • (2000) Clin. Chim. Acta. , vol.30 , pp. 79-85
    • Biosca, C.1    Ricós, C.2    Jiménez, C.V.3    Lauzurica, R.4    Galimany, R.5
  • 17
    • 0035197473 scopus 로고    scopus 로고
    • Reference change value concept combining two delta values to predict crises in renal posttransplantation
    • Biosca C., Ricós C., Lauzurica R., Galimany R., Hyltoft Petersen P. Reference change value concept combining two delta values to predict crises in renal posttransplantation. Clin. Chem. 47:2001;2146-2148
    • (2001) Clin. Chem. , vol.47 , pp. 2146-2148
    • Biosca, C.1    Ricós, C.2    Lauzurica, R.3    Galimany, R.4    Hyltoft Petersen, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.