Volumn 44, Issue 2, 2006, Pages 145-148

The application of a uniform radial ice thickness to structural sections

Author keywords

Design criteria; Ice accretion; Ice loads; Power line icing; Towers; Transmission lines

Indexed keywords

BUILDINGS; ELECTRIC CONDUCTORS; ELECTRIC LINES; ELECTRIC WIRE; FREEZING; POWER TRANSMISSION; RAIN; STRUCTURAL LOADS;

EID: 32244437516     PISSN: 0165232X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.coldregions.2005.10.002     Document Type: Article
Times cited : (14)

References (6)
  • 1
    • 84891366568 scopus 로고    scopus 로고
    • Minimum Design Loads for Buildings and Other Structures ASCE Standard 7-98
    • ASCE American Society of Civil Engineers Reston, VA
    • ASCE Minimum Design Loads for Buildings and Other Structures, ASCE Standard 7-98 2000 American Society of Civil Engineers Reston, VA
    • (2000)
  • 2
    • 84891366568 scopus 로고    scopus 로고
    • Minimum Design Loads for Buildings and Other Structures ASCE Standard 7-02
    • ASCE American Society of Civil Engineers Reston, VA
    • ASCE Minimum Design Loads for Buildings and Other Structures, ASCE Standard 7-02 2002 American Society of Civil Engineers Reston, VA
    • (2002)
  • 3
    • 32244448206 scopus 로고    scopus 로고
    • Atmospheric Icing on structures
    • ISO/TC 98/SC 3 (committee draft, January 1998)
    • ISO, 1998, Atmospheric Icing on structures ISO/TC 98/SC 3 (committee draft, January 1998).
    • (1998)
  • 4
    • 0003485998 scopus 로고    scopus 로고
    • Ice Accretion in Freezing Rain, CRREL Report 96-2
    • Hanover, NH: Cold Regions Research and Engineering Laboratory
    • K.F. Jones Ice Accretion in Freezing Rain, CRREL Report 96-2 1996 Cold Regions Research and Engineering Laboratory Hanover, NH
    • (1996)
    • Jones, K.F.1
  • 5
    • 0032051425 scopus 로고    scopus 로고
    • A simple model for freezing rain ice loads
    • K.F. Jones A simple model for freezing rain ice loads Atmospheric Research 46 1998 87-97
    • (1998) Atmospheric Research , vol.46 , pp. 87-97
    • Jones, K.F.1
  • 6
    • 0004001797 scopus 로고    scopus 로고
    • Structural Standards for Steel Antenna Towers and Antenna Supporting Structures TIA/EIA-222-F
    • TIA Arlington, VA: Telecommunications Industry Association
    • TIA Structural Standards for Steel Antenna Towers and Antenna Supporting Structures TIA/EIA-222-F 1996 Telecommunications Industry Association Arlington, VA
    • (1996)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.