메뉴 건너뛰기




Volumn 63, Issue 4, 2005, Pages 1047-1053

Abnormalities of interatrial septum and ischemic stroke in young people;Alterações do septo interatrial e acidente vascular cerebral isquêmico em adultos jovens

Author keywords

Atrial heart septal defects; Patent foramen ovale; Stroke; Transcranial doppler; Transesophageal echocardiography

Indexed keywords

ADULT; ARTICLE; CARDIOVASCULAR RISK; CEREBROVASCULAR ACCIDENT; CONFIDENCE INTERVAL; CONTROLLED STUDY; DEVELOPING COUNTRY; DISEASE ASSOCIATION; DISEASE CLASSIFICATION; DOPPLER ECHOGRAPHY; FEMALE; FREQUENCY ANALYSIS; HEALTH CARE PLANNING; HEART ANEURYSM; HEART ATRIUM SEPTUM DEFECT; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PREDICTION; RETROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; VALIDATION PROCESS;

EID: 32244436203     PISSN: 0004282X     EISSN: 16784227     Source Type: Journal    
DOI: 10.1590/s0004-282x2005000600025     Document Type: Article
Times cited : (4)

References (29)
  • 1
    • 84858534950 scopus 로고    scopus 로고
    • Ministério da Saúde. Anuário Estatístico de Saúde no Brasil. 2001
    • Ministério da Saúde. Anuário Estatístico de Saúde no Brasil. 2001.
  • 2
    • 0026539303 scopus 로고
    • Infarcts with a cardiac source of embolism in the NINDS Stroke Data Bank: Neurologic examination
    • Kittner SJ, Sharkness CM, Sloan MA, et al. Infarcts with a cardiac source of embolism in the NINDS Stroke Data Bank: neurologic examination. Neurology 1992;42:299-302.
    • (1992) Neurology , vol.42 , pp. 299-302
    • Kittner, S.J.1    Sharkness, C.M.2    Sloan, M.A.3
  • 3
    • 0041851005 scopus 로고    scopus 로고
    • Cardioembolic stroke: An update
    • Ferro JM. Cardioembolic stroke: an update. Lancet Neurol 2003;2:177-188.
    • (2003) Lancet Neurol , vol.2 , pp. 177-188
    • Ferro, J.M.1
  • 4
    • 0023895824 scopus 로고
    • Prevalence of patent foramen ovale in patients with stroke
    • Lechat P, Mas JL, Lascault G, et al. Prevalence of patent foramen ovale in patients with stroke. N Engl J Med 1988;318:1148-1152.
    • (1988) N Engl J Med , vol.318 , pp. 1148-1152
    • Lechat, P.1    Mas, J.L.2    Lascault, G.3
  • 5
    • 4143151776 scopus 로고    scopus 로고
    • Comparison of medical treatment with percutaneous closure of patent foramen ovale in patients with cryptogenic stroke
    • Windecker S, Wahl A, Nedeltchev K, et al. Comparison of medical treatment with percutaneous closure of patent foramen ovale in patients with cryptogenic stroke. J Am Coll Cardiol 2004;44:750-758.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 750-758
    • Windecker, S.1    Wahl, A.2    Nedeltchev, K.3
  • 6
    • 0028337578 scopus 로고
    • A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale
    • Jauss M, Kaps M, Keberle M, Haberbosch W, Dorndorf W. A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium for detection of patent foramen ovale. Stroke 1994;25:1265-1267.
    • (1994) Stroke , vol.25 , pp. 1265-1267
    • Jauss, M.1    Kaps, M.2    Keberle, M.3    Haberbosch, W.4    Dorndorf, W.5
  • 7
    • 0033773515 scopus 로고    scopus 로고
    • Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography
    • Jauss M, Zanette E. Detection of right-to-left shunt with ultrasound contrast agent and transcranial Doppler sonography. Cerebrovasc Dis 2000;10:490-496.
    • (2000) Cerebrovasc Dis , vol.10 , pp. 490-496
    • Jauss, M.1    Zanette, E.2
  • 8
    • 0035379235 scopus 로고    scopus 로고
    • Clinical impact of transesophageal echocardiography in patients with stroke without clinical evidence of cardiovascular sources of emboli
    • Tatani SB, Fukujima MM, Lima JA, et al. Clinical impact of transesophageal echocardiography in patients with stroke without clinical evidence of cardiovascular sources of emboli. Arq Bras Cardiol 2001;76:453-461.
    • (2001) Arq Bras Cardiol , vol.76 , pp. 453-461
    • Tatani, S.B.1    Fukujima, M.M.2    Lima, J.A.3
  • 9
    • 84858535145 scopus 로고    scopus 로고
    • Seleçäo de pacientes para fechamento percutâneo dos defeitos do septo interatrial com a prótese de amplattzer através de um escore ecocardiográfico (E-Eco)
    • Torreäo J, Costa N, Duarte L, Tadeu E, Brito J, Nery A. Seleçäo de pacientes para fechamento percutâneo dos defeitos do septo interatrial com a prótese de amplattzer através de um escore ecocardiográfico (E-Eco). Rev Bras Ecocardiogr 2004;17:57-68.
    • (2004) Rev Bras Ecocardiogr , vol.17 , pp. 57-68
    • Torreäo, J.1    Costa, N.2    Duarte, L.3    Tadeu, E.4    Brito, J.5    Nery, A.6
  • 10
    • 0029194548 scopus 로고
    • Transcranial Doppler sonography: Part 1. Principles, technique, and normal appearances
    • Lupetin AR, Davis DA, Beckman I, Dash N. Transcranial Doppler sonography: Part 1. Principles, technique, and normal appearances. RadioGraphics 1995;15:179-191.
    • (1995) RadioGraphics , vol.15 , pp. 179-191
    • Lupetin, A.R.1    Davis, D.A.2    Beckman, I.3    Dash, N.4
  • 11
    • 0035857141 scopus 로고    scopus 로고
    • Recurrent cerebrovascular events associated with patent foramen ovale, atrial septal aneurysm, or both
    • Mas JL, A rquizan C, Lamy C, et al. Recurrent cerebrovascular events associated with patent foramen ovale, atrial septal aneurysm, or both. N Engl J Med 2001;345:1740-1746.
    • (2001) N Engl J Med , vol.345 , pp. 1740-1746
    • Mas, J.L.1    Arquizan, C.2    Lamy, C.3
  • 12
    • 0027514354 scopus 로고
    • Classification of subtype of acute ischemic stroke. Definitions for use in a multicenter clinical trial. TOAST. Trial of Org 10172 in Acute Stroke Treatment
    • Adams HP. Jr, Bendixen BH, Kappelle LJ, et al. Classification of subtype of acute ischemic stroke. Definitions for use in a multicenter clinical trial. TOAST. Trial of Org 10172 in Acute Stroke Treatment. Stroke 1993;24:35-41.
    • (1993) Stroke , vol.24 , pp. 35-41
    • Adams Jr., H.P.1    Bendixen, B.H.2    Kappelle, L.J.3
  • 13
    • 0034711135 scopus 로고    scopus 로고
    • Interatrial septal abnormalities and stroke: A meta-analysis of case-control studies
    • Overell JR, Bone I, Lees KR. Interatrial septal abnormalities and stroke: a meta-analysis of case-control studies. Neurology 2000;55:1172-1179.
    • (2000) Neurology , vol.55 , pp. 1172-1179
    • Overell, J.R.1    Bone, I.2    Lees, K.R.3
  • 14
    • 0037132876 scopus 로고    scopus 로고
    • Bias and causal associations in observational research
    • Grimes DA, Schulz KF. Bias and causal associations in observational research. Lancet 2002;359:248-252.
    • (2002) Lancet , vol.359 , pp. 248-252
    • Grimes, D.A.1    Schulz, K.F.2
  • 15
    • 0034003573 scopus 로고    scopus 로고
    • Percutaneous closure of patent foramen ovale in patients with paradoxical embolism: Long-term risk of recurrent thromboembolic events
    • Windecker S, Wahl A, Chatterjee T, et al. Percutaneous closure of patent foramen ovale in patients with paradoxical embolism: long-term risk of recurrent thromboembolic events. Circulation 2000;101:893-898.
    • (2000) Circulation , vol.101 , pp. 893-898
    • Windecker, S.1    Wahl, A.2    Chatterjee, T.3
  • 16
    • 0042735258 scopus 로고    scopus 로고
    • Patent foramen ovale: Friend or foe?
    • Castello R, Brott TG. Patent foramen ovale: friend or foe? J Am Coll Cardiol 2003;42:1073-1075.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1073-1075
    • Castello, R.1    Brott, T.G.2
  • 17
    • 0027994381 scopus 로고
    • Comparison of transesophageal and transthoracic echocardiography with contrast and color flow Doppler in the detection of patent foramen ovale
    • Belkin RN, Pollack BD, Ruggiero ML, Alas LL, Tatini U. Comparison of transesophageal and transthoracic echocardiography with contrast and color flow Doppler in the detection of patent foramen ovale. Am Heart J 1994;128:520-525.
    • (1994) Am Heart J , vol.128 , pp. 520-525
    • Belkin, R.N.1    Pollack, B.D.2    Ruggiero, M.L.3    Alas, L.L.4    Tatini, U.5
  • 18
    • 1942499594 scopus 로고    scopus 로고
    • Right-to-left-shunts detected by transesophageal echocardiography and transcranial Doppler sonography
    • D roste DW, Schmidt-Rimpler C, Wichter T, et al. Right-to-left-shunts detected by transesophageal echocardiography and transcranial Doppler sonography. Cerebrovasc Dis 2004;17:191-196.
    • (2004) Cerebrovasc Dis , vol.17 , pp. 191-196
    • Droste, D.W.1    Schmidt-Rimpler, C.2    Wichter, T.3
  • 19
    • 2342661140 scopus 로고    scopus 로고
    • Assessment: Transcranial Doppler ultrasonography: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology
    • Sloan MA, Alexandrov AV, Tegeler CH, et al. Assessment: transcranial Doppler ultrasonography: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. Neurology 2004;62:1468-1481.
    • (2004) Neurology , vol.62 , pp. 1468-1481
    • Sloan, M.A.1    Alexandrov, A.V.2    Tegeler, C.H.3
  • 20
    • 0345404427 scopus 로고    scopus 로고
    • Femoral injection of echo contrast medium may increase the sensitivity of testing for a patent foramen ovale
    • Hamann GF, Schatzer-Klotz D, Frohlig G, et al. Femoral injection of echo contrast medium may increase the sensitivity of testing for a patent foramen ovale. Neurology 1998;50:1423-1428.
    • (1998) Neurology , vol.50 , pp. 1423-1428
    • Hamann, G.F.1    Schatzer-Klotz, D.2    Frohlig, G.3
  • 21
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts
    • Hagen PT, Scholz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc 1984;59:17-20.
    • (1984) Mayo Clin Proc , vol.59 , pp. 17-20
    • Hagen, P.T.1    Scholz, D.G.2    Edwards, W.D.3
  • 22
    • 0042121204 scopus 로고    scopus 로고
    • Prevalence of patent foramen ovale in young patients with cerebral ischemic accident of unknown origin
    • Mesa D, Franco M, Suarez DL, et al. Prevalence of patent foramen ovale in young patients with cerebral ischemic accident of unknown origin. Rev Esp Cardiol 2003;56:662-668.
    • (2003) Rev Esp Cardiol , vol.56 , pp. 662-668
    • Mesa, D.1    Franco, M.2    Suarez, D.L.3
  • 23
    • 0034668078 scopus 로고    scopus 로고
    • The association between the diameter of a patent foramen ovale and the risk of embolic cerebrovascular events
    • Schuchlenz HW, Weihs W, Horner S, Quehenberger F. The association between the diameter of a patent foramen ovale and the risk of embolic cerebrovascular events. Am J Med 2000;109:456-462.
    • (2000) Am J Med , vol.109 , pp. 456-462
    • Schuchlenz, H.W.1    Weihs, W.2    Horner, S.3    Quehenberger, F.4
  • 24
    • 0031971359 scopus 로고    scopus 로고
    • Patent foramen ovale size and embolic brain imaging findings among patients with ischemic stroke
    • Steiner MM, Di Tullio MR, Rundek T, et al. Patent foramen ovale size and embolic brain imaging findings among patients with ischemic stroke. Stroke 1998;29:944-948.
    • (1998) Stroke , vol.29 , pp. 944-948
    • Steiner, M.M.1    Di Tullio, M.R.2    Rundek, T.3
  • 25
    • 3042709663 scopus 로고    scopus 로고
    • Persisting eustachian valve in adults: Relation to patent foramen ovale and cerebrovascular events
    • Schuchlenz HW, Saurer G, Weihs W, Rehak P. Persisting eustachian valve in adults: relation to patent foramen ovale and cerebrovascular events. J Am Soc Echocardiogr 2004;17:231-233.
    • (2004) J Am Soc Echocardiogr , vol.17 , pp. 231-233
    • Schuchlenz, H.W.1    Saurer, G.2    Weihs, W.3    Rehak, P.4
  • 26
    • 0037383973 scopus 로고    scopus 로고
    • Interatrial septal mobility predicts larger shunts across patent foramen ovales: An analysis with transmitral Doppler scanning
    • Fox ER, Picard MH, Chow CM, Levine RA, Schwamm L, Kerr AJ. Interatrial septal mobility predicts larger shunts across patent foramen ovales: an analysis with transmitral Doppler scanning. Am Heart J 2003;145:730-736.
    • (2003) Am Heart J , vol.145 , pp. 730-736
    • Fox, E.R.1    Picard, M.H.2    Chow, C.M.3    Levine, R.A.4    Schwamm, L.5    Kerr, A.J.6
  • 27
    • 0019415084 scopus 로고
    • How to read clinical journals: III. To learn the clinical course and prognosis of disease
    • PMID: 7214 286, PubMed.
    • PMID: 7214 286, PubMed. How to read clinical journals: III. To learn the clinical course and prognosis of disease. Can Med Assoc J 1981;124:869-872.
    • (1981) Can Med Assoc J , vol.124 , pp. 869-872
  • 28
    • 4043090794 scopus 로고    scopus 로고
    • Stroke in young patients: Etiopathogenesis and risk factors in different age classes
    • Cerrato P, Grasso M, Imperiale D, et al. Stroke in young patients: etiopathogenesis and risk factors in different age classes. Cerebrovasc Dis 2004;18:154-159.
    • (2004) Cerebrovasc Dis , vol.18 , pp. 154-159
    • Cerrato, P.1    Grasso, M.2    Imperiale, D.3
  • 29
    • 0037242921 scopus 로고    scopus 로고
    • Association between atrial septal aneurysm and patent foramen ovale in young patients with recent stroke and normal carotid arteries
    • Mattioli AV, Bonetti L, Aquilina M, Oldani A, Longhini C, Mattioli G. Association between atrial septal aneurysm and patent foramen ovale in young patients with recent stroke and normal carotid arteries. Cerebrovasc Dis 2003;15:4-10.
    • (2003) Cerebrovasc Dis , vol.15 , pp. 4-10
    • Mattioli, A.V.1    Bonetti, L.2    Aquilina, M.3    Oldani, A.4    Longhini, C.5    Mattioli, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.