메뉴 건너뛰기




Volumn 47, Issue 1, 2006, Pages 48-57

Virtual bronchoscopy versus thin section computed tomography in evaluation of moderate and low grade stenoses: Receiver operating characteristic curve analysis

Author keywords

Observer performance; Thin section CT; Virtual bronchoscopy

Indexed keywords

BIOLOGICAL MEMBRANES; DIAGNOSIS; ENDOSCOPY; PATIENT MONITORING; STATISTICAL METHODS;

EID: 31744434730     PISSN: 02841851     EISSN: 16000455     Source Type: Journal    
DOI: 10.1080/02841850500406837     Document Type: Article
Times cited : (12)

References (29)
  • 1
    • 0035024453 scopus 로고    scopus 로고
    • Virtual cystoscopy of the bladder based on CT and MRI data
    • Bernhardt TM, Rapp-Bernhardt U. Virtual cystoscopy of the bladder based on CT and MRI data. Abdom Imaging 2001;26:325-32.
    • (2001) Abdom Imaging , vol.26 , pp. 325-332
    • Bernhardt, T.M.1    Rapp-Bernhardt, U.2
  • 2
    • 0030628794 scopus 로고    scopus 로고
    • Central airway stenoses: Preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients
    • Ferretti GR, Knoplioch J, Bricault I, Brambilla C, Coulomb M. Central airway stenoses: preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients. Eur Radiol 1997;7:854-9.
    • (1997) Eur Radiol , vol.7 , pp. 854-859
    • Ferretti, G.R.1    Knoplioch, J.2    Bricault, I.3    Brambilla, C.4    Coulomb, M.5
  • 3
    • 0034110437 scopus 로고    scopus 로고
    • Benign abnormalities and carcinoid tumors of the central airways: Diagnostic impact of CT bronchography
    • Ferretti GR, Thony F, Bosson JL, Pison C, Arbib F, Coulomb M. Benign abnormalities and carcinoid tumors of the central airways: diagnostic impact of CT bronchography. Am J Roentgenol 2000;174:1307-13.
    • (2000) Am J Roentgenol , vol.174 , pp. 1307-1313
    • Ferretti, G.R.1    Thony, F.2    Bosson, J.L.3    Pison, C.4    Arbib, F.5    Coulomb, M.6
  • 5
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristics curves derived from the same cases
    • Hanley JA, McNeil BJ. A method of comparing the areas under receiver operating characteristics curves derived from the same cases. Radiology 1983;148: 839-43.
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 7
    • 0032064022 scopus 로고    scopus 로고
    • Virtual bronchoscopy for three-dimensional pulmonary image assessment: State of the art and future needs
    • Higgins WE, Ramaswamy K, Swift RD, McLennan G, Hoffman EA. Virtual bronchoscopy for three-dimensional pulmonary image assessment: state of the art and future needs. Radiographics 1998;18:761-78.
    • (1998) Radiographics , vol.18 , pp. 761-778
    • Higgins, W.E.1    Ramaswamy, K.2    Swift, R.D.3    McLennan, G.4    Hoffman, E.A.5
  • 8
    • 1242329136 scopus 로고    scopus 로고
    • Grading airway stenosis down to the segmental level using virtual bronchoscopy
    • Hoppe H, Dinkel HP, Walder B, von Allmen G, Gugger M, Vock P. Grading airway stenosis down to the segmental level using virtual bronchoscopy. Chest 2004;125:704-11.
    • (2004) Chest , vol.125 , pp. 704-711
    • Hoppe, H.1    Dinkel, H.P.2    Walder, B.3    Von Allmen, G.4    Gugger, M.5    Vock, P.6
  • 9
    • 0036110271 scopus 로고    scopus 로고
    • Multidetector CT virtual bronchoscopy to grade tracheobronchial stenosis
    • Hoppe H, Walder B, Sonnenschein M, Vock P, Dinkel HP. Multidetector CT virtual bronchoscopy to grade tracheobronchial stenosis. Am J Roentgenol 2002;178:1195-200.
    • (2002) Am J Roentgenol , vol.178 , pp. 1195-1200
    • Hoppe, H.1    Walder, B.2    Sonnenschein, M.3    Vock, P.4    Dinkel, H.P.5
  • 13
    • 0026659872 scopus 로고
    • Statistical analysis with receiver operating characteristic curves
    • Mann FA, Hildebolt CE, Wilson AJ. Statistical analysis with receiver operating characteristic curves. Radiology 1992;184:37-8.
    • (1992) Radiology , vol.184 , pp. 37-38
    • Mann, F.A.1    Hildebolt, C.E.2    Wilson, A.J.3
  • 14
    • 0031647071 scopus 로고    scopus 로고
    • Bronchial anastomotic complications in lung transplant recipients: Virtual bronchoscopy for noninvasive assessment
    • McAdams HP, Palmer SM, Erasmus JJ, Patz EF, Connolly JE, Goodman PC, et al. Bronchial anastomotic complications in lung transplant recipients: virtual bronchoscopy for noninvasive assessment. Radiology 1998;209:689-95.
    • (1998) Radiology , vol.209 , pp. 689-695
    • McAdams, H.P.1    Palmer, S.M.2    Erasmus, J.J.3    Patz, E.F.4    Connolly, J.E.5    Goodman, P.C.6
  • 15
    • 0022470978 scopus 로고
    • ROC methodology in radiologic imaging
    • Metz CE. ROC methodology in radiologic imaging. Invest Radiol 1986;21:720-33.
    • (1986) Invest Radiol , vol.21 , pp. 720-733
    • Metz, C.E.1
  • 16
    • 0024511244 scopus 로고
    • Some practical issues of experimental design and data analysis in radiological ROC studies
    • Metz CE. Some practical issues of experimental design and data analysis in radiological ROC studies. Invest Radiol 1989;24:234-45.
    • (1989) Invest Radiol , vol.24 , pp. 234-245
    • Metz, C.E.1
  • 18
    • 0034014041 scopus 로고    scopus 로고
    • Virtual endoscopy of coronary arteries using contrast-enhanced ECG-triggered electron beam CT data sets
    • Nakanishi T, Kohata M, Miyasaka K, Fukuoka H, Ito K, Imazu M. Virtual endoscopy of coronary arteries using contrast-enhanced ECG-triggered electron beam CT data sets. Am J Roentgenol 2000;174:1345-7.
    • (2000) Am J Roentgenol , vol.174 , pp. 1345-1347
    • Nakanishi, T.1    Kohata, M.2    Miyasaka, K.3    Fukuoka, H.4    Ito, K.5    Imazu, M.6
  • 19
    • 0028836512 scopus 로고
    • Complications of fiberoptic bronchoscopy at a university hospital
    • Pue CA, Pacht ER. Complications of fiberoptic bronchoscopy at a university hospital. Chest 1995;107:430-2.
    • (1995) Chest , vol.107 , pp. 430-432
    • Pue, C.A.1    Pacht, E.R.2
  • 21
    • 0034129965 scopus 로고    scopus 로고
    • Diagnostic potential of virtual bronchoscopy: Advantages in comparison with axial CT slices, MPR and mIP?
    • Rapp-Bernhardt U, Weite T, Doehring W, Kropf S, Bernhardt TM. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP? Eur Radiol 2000;10:981-8.
    • (2000) Eur Radiol , vol.10 , pp. 981-988
    • Rapp-Bernhardt, U.1    Weite, T.2    Doehring, W.3    Kropf, S.4    Bernhardt, T.M.5
  • 22
    • 0026564801 scopus 로고
    • The use of continuous and discrete judgments in receiver operating characteristic studies of diagnostic imaging techniques
    • Rockette HE, Our D, Metz CE. The use of continuous and discrete judgments in receiver operating characteristic studies of diagnostic imaging techniques. Invest Radiol 1992;27:169-72.
    • (1992) Invest Radiol , vol.27 , pp. 169-172
    • Rockette, H.E.1    Our, D.2    Metz, C.E.3
  • 23
    • 0030827117 scopus 로고    scopus 로고
    • CT colonoscopy of colorectal neoplasms: Two-dimensional and three-dimensional virtual-reality techniques with colonoscopic correlation
    • Royster AP, Fenlon HM, Clarke PD, Nunes DP, Ferrucci JT. CT colonoscopy of colorectal neoplasms: two-dimensional and three-dimensional virtual-reality techniques with colonoscopic correlation. Am J Roentgenol 1997;169:1237-42.
    • (1997) Am J Roentgenol , vol.169 , pp. 1237-1242
    • Royster, A.P.1    Fenlon, H.M.2    Clarke, P.D.3    Nunes, D.P.4    Ferrucci, J.T.5
  • 25
    • 0023178574 scopus 로고
    • Fiberoptic bronchoscopy: Diagnostic applications
    • Shure D. Fiberoptic bronchoscopy: diagnostic applications. Clin Chest Med 1987;8:1-13.
    • (1987) Clin Chest Med , vol.8 , pp. 1-13
    • Shure, D.1
  • 26
    • 0037372793 scopus 로고    scopus 로고
    • Comparison of eight computer programs for receiver-operating characteristic analysis
    • Stephan C, Wesseling S, Schink T, Jung K. Comparison of eight computer programs for receiver-operating characteristic analysis. Clin Chem 2003;49:433-9.
    • (2003) Clin Chem , vol.49 , pp. 433-439
    • Stephan, C.1    Wesseling, S.2    Schink, T.3    Jung, K.4
  • 27
    • 0031136996 scopus 로고    scopus 로고
    • Navigational aids for real-time virtual bronchoscopy
    • Summers RM. Navigational aids for real-time virtual bronchoscopy. Am J Roentgenol 1997;168:1165-70.
    • (1997) Am J Roentgenol , vol.168 , pp. 1165-1170
    • Summers, R.M.1
  • 28
    • 0036155051 scopus 로고    scopus 로고
    • CT virtual bronchoscopy of the central airways in patients with Wegener's granulomatosis
    • Summers RM, Aggarwal NR, Sneller MC, Cowan MJ, Wood BJ, Langford CA, et al. CT virtual bronchoscopy of the central airways in patients with Wegener's granulomatosis. Chest 2002;121:242-50.
    • (2002) Chest , vol.121 , pp. 242-250
    • Summers, R.M.1    Aggarwal, N.R.2    Sneller, M.C.3    Cowan, M.J.4    Wood, B.J.5    Langford, C.A.6
  • 29
    • 0031920615 scopus 로고    scopus 로고
    • CT virtual bronchoscopy of simulated endobronchial lesions: Effect of scanning, reconstruction and display settings and potential pitfalls
    • Summers RM, Shaw DJ, Shelhamer JH. CT virtual bronchoscopy of simulated endobronchial lesions: effect of scanning, reconstruction and display settings and potential pitfalls. Am J Roentgenol 1998;170: 947-50.
    • (1998) Am J Roentgenol , vol.170 , pp. 947-950
    • Summers, R.M.1    Shaw, D.J.2    Shelhamer, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.