메뉴 건너뛰기




Volumn 45, Issue 2, 2004, Pages 176-183

Threshold selection in virtual bronchoscopy: Phantom study and clinical implications

Author keywords

Bronchi, CT; Computed tomography; Phantom; Virtual reality imaging

Indexed keywords

APPROXIMATION THEORY; COMPUTATIONAL METHODS; COMPUTERIZED TOMOGRAPHY; CORRELATION METHODS; MEDICAL IMAGING; MORPHOLOGY; PARAMETER ESTIMATION;

EID: 2442575884     PISSN: 02841851     EISSN: None     Source Type: Journal    
DOI: 10.1080/02841850410003761     Document Type: Article
Times cited : (3)

References (18)
  • 1
    • 0030628794 scopus 로고    scopus 로고
    • Central airway stenoses: Preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients
    • Ferretti GR, Knoplioch J, Bricault I, Brambilla C, Coulomb M. Central airway stenoses: preliminary results of spiral-CT-generated virtual bronchoscopy simulations in 29 patients. Eur Radiol 1997;7:854-9.
    • (1997) Eur Radiol , vol.7 , pp. 854-859
    • Ferretti, G.R.1    Knoplioch, J.2    Bricault, I.3    Brambilla, C.4    Coulomb, M.5
  • 2
    • 85135546435 scopus 로고    scopus 로고
    • Tracheobronchial tree: Three dimensional spiral CT with bronchoscopic perspective
    • Ferretti GR, Vining DJ, Knoplioch J, Coulomb M. Tracheobronchial tree: three dimensional spiral CT with bronchoscopic perspective. J Comput Assist Tomogr 1996;19:341-7.
    • (1996) J Comput Assist Tomogr , vol.19 , pp. 341-347
    • Ferretti, G.R.1    Vining, D.J.2    Knoplioch, J.3    Coulomb, M.4
  • 3
    • 0031298043 scopus 로고    scopus 로고
    • Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinoma: Opportunities and limitations
    • Fleiter T, Merkle EM, Aschoff AJ, Lang G, Stein M, Gorich J, et al. Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinoma: opportunities and limitations. Am J Roentgenol 1997;169:1591-5.
    • (1997) Am J Roentgenol , vol.169 , pp. 1591-1595
    • Fleiter, T.1    Merkle, E.M.2    Aschoff, A.J.3    Lang, G.4    Stein, M.5    Gorich, J.6
  • 5
    • 0023381475 scopus 로고
    • Marching cubes: A high resolution 3D surface construction system
    • Lorensen WE, Cline HE. Marching cubes: a high resolution 3D surface construction system. Comput Graphics 1987;21:163-9.
    • (1987) Comput Graphics , vol.21 , pp. 163-169
    • Lorensen, W.E.1    Cline, H.E.2
  • 6
    • 0031647071 scopus 로고    scopus 로고
    • Bronchial anastomotic complications in lung transplant recipients: Virtual bronchoscopy for noninvasive assessment
    • McAdams HP, Palmer SM, Erasmus JJ, Patz EF, Connolly JE, Goodman PC, et al. Bronchial anastomotic complications in lung transplant recipients: virtual bronchoscopy for noninvasive assessment. Radiology 1998;209:689-95.
    • (1998) Radiology , vol.209 , pp. 689-695
    • McAdams, H.P.1    Palmer, S.M.2    Erasmus, J.J.3    Patz, E.F.4    Connolly, J.E.5    Goodman, P.C.6
  • 8
    • 0034129965 scopus 로고    scopus 로고
    • Diagnostic potential of virtual bronchoscopy: Advantages in comparison with axial CT slices, MPR and MIP
    • Rapp-Bernhardt U, Welte T, Doehring W, Kropf S, Bernhardt TM. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and MIP. Eur Radiol 2000;10:981-8.
    • (2000) Eur Radiol , vol.10 , pp. 981-988
    • Rapp-Bernhardt, U.1    Welte, T.2    Doehring, W.3    Kropf, S.4    Bernhardt, T.M.5
  • 10
    • 0031600214 scopus 로고    scopus 로고
    • Multiplanar and three-dimensional reconstruction techniques in CT: Impact on chest diseases
    • Remy J, Remy-Jardin M, Artaud D, Fribourg M. Multiplanar and three-dimensional reconstruction techniques in CT: impact on chest diseases. Eur Radiol 1998;8:335-51.
    • (1998) Eur Radiol , vol.8 , pp. 335-351
    • Remy, J.1    Remy-Jardin, M.2    Artaud, D.3    Fribourg, M.4
  • 11
    • 0029988087 scopus 로고    scopus 로고
    • Perspective volume rendering of CT and MR images: Applications for endoscopic imaging
    • Rubin GD, Beaulieu CF, Argiro V, Ringl H, Norbash AM, Feller JF, et al. Perspective volume rendering of CT and MR images: applications for endoscopic imaging. Radiology 1996;199:321-30.
    • (1996) Radiology , vol.199 , pp. 321-330
    • Rubin, G.D.1    Beaulieu, C.F.2    Argiro, V.3    Ringl, H.4    Norbash, A.M.5    Feller, J.F.6
  • 12
    • 0036155051 scopus 로고    scopus 로고
    • CT virtual bronchoscopy of the central airways in patients with Wegener's granulomatosis
    • Summers RM, Aggarwal NR, Sneller MC, Cowan MJ, Wood BJ, Langford CA, et al. CT virtual bronchoscopy of the central airways in patients with Wegener's granulomatosis. Chest 2002;121:242-50.
    • (2002) Chest , vol.121 , pp. 242-250
    • Summers, R.M.1    Aggarwal, N.R.2    Sneller, M.C.3    Cowan, M.J.4    Wood, B.J.5    Langford, C.A.6
  • 14
    • 0031920615 scopus 로고    scopus 로고
    • CT virtual bronchoscopy of simulated endobronchial lesions: Effect of scanning, reconstruction, and display settings and potential pitfalls
    • Summers RM, Shaw DJ, Shelhamer JH. CT virtual bronchoscopy of simulated endobronchial lesions: effect of scanning, reconstruction, and display settings and potential pitfalls. Am J Roentgenol 1998;170:947-50.
    • (1998) Am J Roentgenol , vol.170 , pp. 947-950
    • Summers, R.M.1    Shaw, D.J.2    Shelhamer, J.H.3
  • 15
    • 0028230441 scopus 로고
    • Stair-step artifacts in three-dimensional helical CT: An experimental study
    • Wang G, Vannier MW. Stair-step artifacts in three-dimensional helical CT: an experimental study. Radiology 1994;191:79-83.
    • (1994) Radiology , vol.191 , pp. 79-83
    • Wang, G.1    Vannier, M.W.2
  • 16
    • 0021145887 scopus 로고
    • CT of a bronchial phantom: Factors affecting appearance and size measurements
    • Webb WR, Gamsu G, Wall SD, Cann CE, Proctor E. CT of a bronchial phantom: factors affecting appearance and size measurements. Invest Radiol 1984;19:394-8.
    • (1984) Invest Radiol , vol.19 , pp. 394-398
    • Webb, W.R.1    Gamsu, G.2    Wall, S.D.3    Cann, C.E.4    Proctor, E.5
  • 17
    • 0020620090 scopus 로고
    • Computed tomography: Beam hardening and environmental density artifact
    • Young SW, Muller HH, Marshall WH. Computed tomography: beam hardening and environmental density artifact. Radiology 1983;148:279-83.
    • (1983) Radiology , vol.148 , pp. 279-283
    • Young, S.W.1    Muller, H.H.2    Marshall, W.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.