메뉴 건너뛰기




Volumn 41, Issue 2, 2005, Pages 171-179

The network of the Italian laboratories: A proficiency test on the quantification of trace elements in serum

Author keywords

Biological fluid; Proficiency test; Serum; Trace elements

Indexed keywords

ALUMINUM; COPPER; MANGANESE; RUBIDIUM; SELENIUM; TRACE ELEMENT; VANADIUM; ZINC;

EID: 31644440160     PISSN: 00212571     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (10)
  • 1
    • 31644434569 scopus 로고    scopus 로고
    • Part I: Development and operation of proficiency testing schemes
    • Guide 43-1. ISO/IEC 16
    • International Organization for Standardization (ISO). Proficiency testing by interlaboratory comparisons. Part I: Development and operation of proficiency testing schemes. Guide 43-1. ISO/IEC 16; 1997.
    • (1997) Proficiency Testing by Interlaboratory Comparisons
  • 2
    • 0001444598 scopus 로고
    • Multivariate analysis of a round-robin study on the measurement of chlorobiphenyls in fish oil
    • Misra RK, Uthe JF, Musial CJ. Multivariate analysis of a round-robin study on the measurement of chlorobiphenyls in fish oil. Analyst 1992;117:1085-91.
    • (1992) Analyst , vol.117 , pp. 1085-1091
    • Misra, R.K.1    Uthe, J.F.2    Musial, C.J.3
  • 3
    • 37049077807 scopus 로고
    • Proficiency testing of analytical laboratories: Organization and statistical assessment
    • Analytical Methods Committee. Proficiency testing of analytical laboratories: organization and statistical assessment. Analyst 1992;117:97-104.
    • (1992) Analyst , vol.117 , pp. 97-104
  • 5
    • 31644445667 scopus 로고
    • Groningen: Quality assurance group inspectorate for health protection; 3rd Edition
    • CHEK. Protocol for proficiency testing. Groningen: Quality assurance group inspectorate for health protection; 3rd Edition 1995. p. 1-50.
    • (1995) Protocol for Proficiency Testing , pp. 1-50
  • 8
    • 0001960236 scopus 로고
    • Graphical diagrams of interlaboratory test results
    • Youden WJ. Graphical diagrams of interlaboratory test results. J Ind Qual Control 1959;11:133-7.
    • (1959) J Ind Qual Control , vol.11 , pp. 133-137
    • Youden, W.J.1
  • 9
    • 0030926242 scopus 로고    scopus 로고
    • The concept of uncertainty as applied to chemical measurements
    • Horwitz W, Albert R. The concept of uncertainty as applied to chemical measurements. Analyst 1997;122:615-7.
    • (1997) Analyst , vol.122 , pp. 615-617
    • Horwitz, W.1    Albert, R.2
  • 10
    • 0034110836 scopus 로고    scopus 로고
    • Recent trends in inter-laboratory precision at ppb and sub-ppb concentrations in relation to fitness for purpose criteria in proficiency testing
    • Thompson M. Recent trends in inter-laboratory precision at ppb and sub-ppb concentrations in relation to fitness for purpose criteria in proficiency testing. Analyst 2000;125:385-6.
    • (2000) Analyst , vol.125 , pp. 385-386
    • Thompson, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.