메뉴 건너뛰기




Volumn 226, Issue 1, 2003, Pages 231-234

Detection of pulmonary metastases with multi-detector row CT scans of 5-mm nominal section thickness: Autopsy lung study

Author keywords

Computed tomography (CT), helical; Computed tomography (CT), multi detector row; Experimental study; Lung neoplasms, metastases; Lung, nodule

Indexed keywords

ARTICLE; AUTOPSY; CANCER LOCALIZATION; CLINICAL ARTICLE; COLLIMATOR; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; LUNG METASTASIS; PITCH; PRIORITY JOURNAL; ROTATION; TECHNIQUE; THICKNESS;

EID: 0037257550     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2261010394     Document Type: Article
Times cited : (22)

References (15)
  • 1
    • 0034330627 scopus 로고    scopus 로고
    • Multisection CT: Scanning techniques and clinical applications
    • Rydberg J, Buckwalter KA, Caldemeyer KS, et al. Multisection CT: scanning techniques and clinical applications. Radio-Graphics 2000; 20:1787-1806.
    • (2000) Radio-Graphics , vol.20 , pp. 1787-1806
    • Rydberg, J.1    Buckwalter, K.A.2    Caldemeyer, K.S.3
  • 4
    • 0018380331 scopus 로고
    • Evaluation of computed tomography in the detection of pulmonary metastases: A prospective study
    • Chang AE, Schaner EG, Conkle DM, Flye MW, Doppman JL, Rosenberg SA. Evaluation of computed tomography in the detection of pulmonary metastases: a prospective study. Cancer 1979; 43:913-916.
    • (1979) Cancer , vol.43 , pp. 913-916
    • Chang, A.E.1    Schaner, E.G.2    Conkle, D.M.3    Flye, M.W.4    Doppman, J.L.5    Rosenberg, S.A.6
  • 5
    • 0020363559 scopus 로고
    • Failure to detect a 1.5 centimeter lung nodule by chest computed tomography
    • Krudy AG, Doppman JL, Herdt JR. Failure to detect a 1.5 centimeter lung nodule by chest computed tomography. J Comput Assist Tomogr 1982; 6:1178-1180.
    • (1982) J Comput Assist Tomogr , vol.6 , pp. 1178-1180
    • Krudy, A.G.1    Doppman, J.L.2    Herdt, J.R.3
  • 6
    • 0025179432 scopus 로고
    • Lung: Spiral volumetric CT with single-breath-hold technique
    • Vock P, Soucek M, Daepp M, Kalender WA. Lung: spiral volumetric CT with single-breath-hold technique. Radiology 1990; 176:864-867.
    • (1990) Radiology , vol.176 , pp. 864-867
    • Vock, P.1    Soucek, M.2    Daepp, M.3    Kalender, W.A.4
  • 7
    • 0025855784 scopus 로고
    • Pulmonary nodule: Evaluation with spiral volumetric CT
    • Costello P, Anderson W, Blume D. Pulmonary nodule: evaluation with spiral volumetric CT. Radiology 1991; 179:875-876.
    • (1991) Radiology , vol.179 , pp. 875-876
    • Costello, P.1    Anderson, W.2    Blume, D.3
  • 9
    • 0027245609 scopus 로고
    • Pulmonary nodules: Detection with thick-section spiral CT versus conventional CT
    • Remy-Jardin M, Remy J, Giraud F, Marquette CH. Pulmonary nodules: detection with thick-section spiral CT versus conventional CT. Radiology 1993; 187:513-520.
    • (1993) Radiology , vol.187 , pp. 513-520
    • Remy-Jardin, M.1    Remy, J.2    Giraud, F.3    Marquette, C.H.4
  • 11
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • Polacin A, Kalender WA, Marchal G, Evaluation of section sensitivity profiles and image noise in spiral CT. Radiology 1992; 185:29-35.
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 12
    • 0032617143 scopus 로고    scopus 로고
    • Detection of pulmonary nodules with overlapping vs non-overlapping image reconstruction at spiral CT
    • Diederich S, Lentschig MG, Winter F, Roos N, Bongartz G. Detection of pulmonary nodules with overlapping vs non-overlapping image reconstruction at spiral CT. Eur Radiol 1999; 9:281-286.
    • (1999) Eur Radiol , vol.9 , pp. 281-286
    • Diederich, S.1    Lentschig, M.G.2    Winter, F.3    Roos, N.4    Bongartz, G.5
  • 13
    • 0032909316 scopus 로고    scopus 로고
    • Helical CT of pulmonary nodules in patients with extrathoracic malignancy: CT-surgical correlation
    • Diederich S, Semik M, Lentschig MG, et al. Helical CT of pulmonary nodules in patients with extrathoracic malignancy: CT-surgical correlation. AJR Am J Roentgenol 1999; 172:353-360.
    • (1999) AJR Am J Roentgenol , vol.172 , pp. 353-360
    • Diederich, S.1    Semik, M.2    Lentschig, M.G.3
  • 14
    • 0032718470 scopus 로고    scopus 로고
    • Performance evaluation of a multi-slice CT system
    • McCollough CH, Zink FE. Performance evaluation of a multi-slice CT system. Med Phys 1999; 26:2223-2230.
    • (1999) Med Phys , vol.26 , pp. 2223-2230
    • McCollough, C.H.1    Zink, F.E.2
  • 15
    • 0034069213 scopus 로고    scopus 로고
    • Four multidetector-row helical CT: Image quality and volume coverage speed
    • Hu H, He HD, Foley WD, Fox SH. Four multidetector-row helical CT: image quality and volume coverage speed. Radiology 2000; 215:55-62.
    • (2000) Radiology , vol.215 , pp. 55-62
    • Hu, H.1    He, H.D.2    Foley, W.D.3    Fox, S.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.