메뉴 건너뛰기




Volumn 6, Issue 4, 2004, Pages 330-335

A comparison of open irrigated and non-irrigated tip catheter ablation for pulmonary vein isolation

Author keywords

Atrial fibrillation; Cooled tip; Irrigated tip; Pulmonary vein isolation; Pulmonary veins; Radiofrequency ablation

Indexed keywords

AMIODARONE; ANTIARRHYTHMIC AGENT;

EID: 3142672759     PISSN: 10995129     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.eupc.2004.03.001     Document Type: Article
Times cited : (53)

References (19)
  • 1
    • 0035940379 scopus 로고    scopus 로고
    • ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: Executive summary
    • Fuster V. Rydén L.E. Asinger R.W. et al. ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: executive summary Circulation 104 2001 2118-2150
    • (2001) Circulation , vol.104 , pp. 2118-2150
    • Fuster, V.1    Rydén, L.E.2    Asinger, R.W.3
  • 2
    • 0032480265 scopus 로고    scopus 로고
    • Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    • Hässaguerre M. Jäs P. Shah D.C. et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins N Engl J Med 339 1998 659-666
    • (1998) N. Engl. J. Med. , vol.339 , pp. 659-666
    • Hässaguerre, M.1    Jäs, P.2    Shah, D.C.3
  • 3
    • 0033517860 scopus 로고    scopus 로고
    • Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    • Chen S.A. Hsieh M.H. Tai C.T. et al. Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation Circulation 100 1999 1879-1886
    • (1999) Circulation , vol.100 , pp. 1879-1886
    • Chen, S.A.1    Hsieh, M.H.2    Tai, C.T.3
  • 4
    • 0034649299 scopus 로고    scopus 로고
    • Electrophysiological breakthroughs from the left atrium to the pulmonary veins
    • Hässaguerre M. Shah D.C. Jäs P. et al. Electrophysiological breakthroughs from the left atrium to the pulmonary veins Circulation 102 2000 2463-2465
    • (2000) Circulation , vol.102 , pp. 2463-2465
    • Hässaguerre, M.1    Shah, D.C.2    Jäs, P.3
  • 5
    • 0037123158 scopus 로고    scopus 로고
    • Electrogram polarity reversal as an additional indicator of breakthroughs from the left atrium to the pulmonary veins
    • Yamane T. Shah D.C. Jäs P. et al. Electrogram polarity reversal as an additional indicator of breakthroughs from the left atrium to the pulmonary veins J Am Coll Cardiol 39 2002 1337-1344
    • (2002) J. Am. Coll. Cardiol. , vol.39 , pp. 1337-1344
    • Yamane, T.1    Shah, D.C.2    Jäs, P.3
  • 6
    • 0037022841 scopus 로고    scopus 로고
    • Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation
    • Oral H. Knight B.P. Tada H. et al. Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation Circulation 105 2002 1077-1081
    • (2002) Circulation , vol.105 , pp. 1077-1081
    • Oral, H.1    Knight, B.P.2    Tada, H.3
  • 7
    • 0037036848 scopus 로고    scopus 로고
    • Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: Impact of different catheter technologies
    • Marrouche N.F. Dresing T. Cole C. et al. Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation: impact of different catheter technologies J Am Coll Cardiol 40 2002 464-474
    • (2002) J. Am. Coll. Cardiol. , vol.40 , pp. 464-474
    • Marrouche, N.F.1    Dresing, T.2    Cole, C.3
  • 8
    • 0035691248 scopus 로고    scopus 로고
    • Empirical pulmonary vein isolation in patients with chronic atrial fibrillation using a three-dimensional nonfluoroscopic mapping system: Long-term follow-up
    • Kanagaratnam L. Tomassoni G. Schweikert R. et al. Empirical pulmonary vein isolation in patients with chronic atrial fibrillation using a three-dimensional nonfluoroscopic mapping system: long-term follow-up Pacing Clin Electrophysiol 24 2001 1774-1779
    • (2001) Pacing Clin. Electrophysiol. , vol.24 , pp. 1774-1779
    • Kanagaratnam, L.1    Tomassoni, G.2    Schweikert, R.3
  • 9
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • Nakagawa H. Yamanashi W.S. Pitha J.V. et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation Circulation 91 1995 2264-2273
    • (1995) Circulation , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3
  • 10
    • 0034700269 scopus 로고    scopus 로고
    • Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation
    • Yamane T. Jäs P. Shah D.C. et al. Efficacy and safety of an irrigated-tip catheter for the ablation of accessory pathways resistant to conventional radiofrequency ablation Circulation 102 2000 2565-2568
    • (2000) Circulation , vol.102 , pp. 2565-2568
    • Yamane, T.1    Jäs, P.2    Shah, D.C.3
  • 11
    • 0342470431 scopus 로고    scopus 로고
    • Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter
    • Jäs P. Shah D.C. Hässaguerre M. et al. Prospective randomized comparison of irrigated-tip versus conventional-tip catheters for ablation of common flutter Circulation 101 2000 772-776
    • (2000) Circulation , vol.101 , pp. 772-776
    • Jäs, P.1    Shah, D.C.2    Hässaguerre, M.3
  • 12
    • 0035115581 scopus 로고    scopus 로고
    • Use of a saline-irrigated tip catheter for ablation of ventricular tachycardia resistant to conventional radiofrequency ablation: Early experience
    • Nabar A. Rodriguez L.M. Timmermans C. et al. Use of a saline-irrigated tip catheter for ablation of ventricular tachycardia resistant to conventional radiofrequency ablation: early experience J Cardiovasc Electrophysiol 12 2001 153-161
    • (2001) J. Cardiovasc. Electrophysiol. , vol.12 , pp. 153-161
    • Nabar, A.1    Rodriguez, L.M.2    Timmermans, C.3
  • 13
    • 0036851340 scopus 로고    scopus 로고
    • Irrigated-tip catheter ablation of pulmonary veins for treatment of atrial fibrillation
    • Macle L. Jäs P. Weerasooriya R. et al. Irrigated-tip catheter ablation of pulmonary veins for treatment of atrial fibrillation J Cardiovasc Electrophysiol 13 2002 1067-1073
    • (2002) J. Cardiovasc. Electrophysiol. , vol.13 , pp. 1067-1073
    • Macle, L.1    Jäs, P.2    Weerasooriya, R.3
  • 14
    • 0037129904 scopus 로고    scopus 로고
    • Left atrial appendage activity masquerading as pulmonary vein potentials
    • Shah D. Hässaguerre M. Jäs P. et al. Left atrial appendage activity masquerading as pulmonary vein potentials Circulation 105 2002 2821-2825
    • (2002) Circulation , vol.105 , pp. 2821-2825
    • Shah, D.1    Hässaguerre, M.2    Jäs, P.3
  • 15
    • 0037014593 scopus 로고    scopus 로고
    • Clinical significance of early recurrences of atrial fibrillation after pulmonary vein isolation
    • Oral H. Knight B.P. Ozaydin M. et al. Clinical significance of early recurrences of atrial fibrillation after pulmonary vein isolation J Am Coll Cardiol 40 2002 100-104
    • (2002) J. Am. Coll. Cardiol. , vol.40 , pp. 100-104
    • Oral, H.1    Knight, B.P.2    Ozaydin, M.3
  • 16
    • 0034776746 scopus 로고    scopus 로고
    • Curative catheter ablation of paroxysmal atrial fibrillation in 200 patients: Strategy for presentations ranging from sustained atrial fibrillation to no arrhythmias
    • Shah D.C. Hässaguerre M. Jäs P. et al. Curative catheter ablation of paroxysmal atrial fibrillation in 200 patients: strategy for presentations ranging from sustained atrial fibrillation to no arrhythmias Pacing Clin Electrophysiol 24 2001 1541-1558
    • (2001) Pacing Clin. Electrophysiol. , vol.24 , pp. 1541-1558
    • Shah, D.C.1    Hässaguerre, M.2    Jäs, P.3
  • 17
    • 0343729318 scopus 로고    scopus 로고
    • Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci
    • Hässaguerre M. Jäs P. Shah D.C. et al. Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci Circulation 101 2000 1409-1417
    • (2000) Circulation , vol.101 , pp. 1409-1417
    • Hässaguerre, M.1    Jäs, P.2    Shah, D.C.3
  • 18
    • 0038516683 scopus 로고    scopus 로고
    • Increasing power versus duration for radiofrequency ablation with a high superfusate flow: Implications for pulmonary vein ablation
    • In press
    • Guy D. Boyd A. Thomas S. et al. Increasing power versus duration for radiofrequency ablation with a high superfusate flow: implications for pulmonary vein ablation. Pacing Clin Electrophysiol, in press
    • Pacing Clin. Electrophysiol.
    • Guy, D.1    Boyd, A.2    Thomas, S.3
  • 19
    • 0033972402 scopus 로고    scopus 로고
    • Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation
    • Petersen H.H. Chen X. Pietersen A. et al. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: an in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation Pacing Clin Electrophysiol 23 2000 8-17
    • (2000) Pacing Clin. Electrophysiol. , vol.23 , pp. 8-17
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.