메뉴 건너뛰기




Volumn 26, Issue 6, 2003, Pages 1379-1385

Increasing power versus duration for radiofrequency ablation with a high superfusate flow: Implications for pulmonary vein ablation?

Author keywords

Arrhythmia; Catheter ablation; Electrophysiology

Indexed keywords

ANIMAL TISSUE; ARTICLE; BLOOD FLOW; BLOOD VESSEL WALL; CATHETER; CATHETER ABLATION; CATTLE; DISEASE COURSE; FLOW MEASUREMENT; NONHUMAN; PULMONARY VEIN; RADIOFREQUENCY; RISK ASSESSMENT; TEMPERATURE; THICKNESS; TIME; VEIN INJURY;

EID: 0038516683     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2003.t01-1-00197.x     Document Type: Article
Times cited : (13)

References (18)
  • 1
    • 0032480265 scopus 로고    scopus 로고
    • Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    • Haissaguerre M, Jais P, Shah DC, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med 1998; 339:659-666.
    • (1998) N Engl J Med , vol.339 , pp. 659-666
    • Haissaguerre, M.1    Jais, P.2    Shah, D.C.3
  • 2
    • 0037022841 scopus 로고    scopus 로고
    • Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation
    • Oral H, Knight BP, Tada H, et al. Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation. Circulation 2002; 105:1077-1081.
    • (2002) Circulation , vol.105 , pp. 1077-1081
    • Oral, H.1    Knight, B.P.2    Tada, H.3
  • 3
    • 0033983102 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of atrial fibrillation initiated by pulmonary vein ectopic beats
    • Chen SA, Tai CT, Tsai CF, et al. Radiofrequency catheter ablation of atrial fibrillation initiated by pulmonary vein ectopic beats. J Cardiovasc Electrophysiol 2000; 11:218-227.
    • (2000) J Cardiovasc Electrophysiol , vol.11 , pp. 218-227
    • Chen, S.A.1    Tai, C.T.2    Tsai, C.F.3
  • 4
    • 0033517860 scopus 로고    scopus 로고
    • Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    • Chen SA, Hsieh MH, Tai CT, et al. Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation. Circulation 1999; 100:1879-1886.
    • (1999) Circulation , vol.100 , pp. 1879-1886
    • Chen, S.A.1    Hsieh, M.H.2    Tai, C.T.3
  • 5
    • 0031041194 scopus 로고    scopus 로고
    • A focal source of atrial fibrillation treated by discrete radiofrequency ablation
    • Jais P, Haissaguerre M, Shah DC, et al. A focal source of atrial fibrillation treated by discrete radiofrequency ablation. Circulation 1997; 95:572-576.
    • (1997) Circulation , vol.95 , pp. 572-576
    • Jais, P.1    Haissaguerre, M.2    Shah, D.C.3
  • 6
    • 0034700286 scopus 로고    scopus 로고
    • Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation
    • Pappone C, Rosanio S, Oreto G, et al. Circumferential radiofrequency ablation of pulmonary vein ostia: A new anatomic approach for curing atrial fibrillation. Circulation 2000; 102:2619-2628.
    • (2000) Circulation , vol.102 , pp. 2619-2628
    • Pappone, C.1    Rosanio, S.2    Oreto, G.3
  • 7
    • 0026453209 scopus 로고
    • Temperature monitoring during radiofrequency catheter ablation of accessory pathways
    • Langberg JJ, Calkins H, Atassi R, et al. Temperature monitoring during radiofrequency catheter ablation of accessory pathways. Circulation 1992; 86:1469-1474.
    • (1992) Circulation , vol.86 , pp. 1469-1474
    • Langberg, J.J.1    Calkins, H.2    Atassi, R.3
  • 8
    • 0031885671 scopus 로고    scopus 로고
    • Effects of intracavitary blood flow and electrode-target distance on radiofrequency power required for transient conduction block in a Langendorff-perfused canine model
    • Simmers TA, de Bakker JM, Coronel R, et al. Effects of intracavitary blood flow and electrode-target distance on radiofrequency power required for transient conduction block in a Langendorff-perfused canine model. J Am Coll Cardiol 1998; 31:231-235.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 231-235
    • Simmers, T.A.1    De Bakker, J.M.2    Coronel, R.3
  • 9
    • 0031930039 scopus 로고    scopus 로고
    • Lesion size in relation to ablation site during radiofrequency ablation
    • PetersenHH, Chen X, PietersenA, et al. Lesion size in relation to ablation site during radiofrequency ablation. PACE 1998; 21:322-326.
    • (1998) PACE , vol.21 , pp. 322-326
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3
  • 10
    • 0032746876 scopus 로고    scopus 로고
    • Anatomy of the left atrium: Implications for radiofrequency ablation of atrial fibrillation
    • Ho SY, Sanchez-Quintana D, Cabrera JA, et al. Anatomy of the left atrium: Implications for radiofrequency ablation of atrial fibrillation. J Cardiovasc Electrophysiol 1999; 10:1525-1533.
    • (1999) J Cardiovasc Electrophysiol , vol.10 , pp. 1525-1533
    • Ho, S.Y.1    Sanchez-Quintana, D.2    Cabrera, J.A.3
  • 11
    • 0012204301 scopus 로고
    • Postmortem: Histochemical techniques
    • Wagner WG. (ed.). The Hague/Boston/London, Martinus Nijhoff
    • Fallon JT. Postmortem: Histochemical techniques. In Wagner WG. (ed.) Myocardial Infarction: Measurement and Intervention. The Hague/Boston/London, Martinus Nijhoff, 1982, pp. 373-384.
    • (1982) Myocardial Infarction: Measurement and Intervention , pp. 373-384
    • Fallon, J.T.1
  • 12
    • 0027438063 scopus 로고
    • Cellular electrophysiological effects of hyperthermia on isolated guinea pig papillary muscle. Implications for catheter ablation
    • Nath S, Lynch C III, Whayne JG, et al. Cellular electrophysiological effects of hyperthermia on isolated guinea pig papillary muscle. Implications for catheter ablation. Circulation. 1993; 88:1826-1831.
    • (1993) Circulation , vol.88 , pp. 1826-1831
    • Nath, S.1    Lynch C. III2    Whayne, J.G.3
  • 13
    • 0028209986 scopus 로고
    • Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury
    • Whayne JG, Nath S, Haines DE. Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury. Circulation 1994; 89:2390-2395.
    • (1994) Circulation , vol.89 , pp. 2390-2395
    • Whayne, J.G.1    Nath, S.2    Haines, D.E.3
  • 15
    • 0033208610 scopus 로고    scopus 로고
    • Temperature-controlled radiofrequency ablation of cardiac tissue: An in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling
    • Petersen HH, Chen X, Pietersen A, et al. Temperature-controlled radiofrequency ablation of cardiac tissue: an in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling. J Interv Card Electrophysiol. 1999; 3:257-262.
    • (1999) J Interv Card Electrophysiol , vol.3 , pp. 257-262
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3
  • 16
    • 0033972402 scopus 로고    scopus 로고
    • Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature- controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation
    • Petersen HH, Chen X, Pietersen A, et al. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature- controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation. PACE 2000; 23:8-17.
    • (2000) PACE , vol.23 , pp. 8-17
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3
  • 17
    • 0028942447 scopus 로고
    • Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation
    • Nakagawa H, Yamanashi WS, Pitha JV, et al. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Circulation 1995; 91:2264-2273.
    • (1995) Circulation , vol.91 , pp. 2264-2273
    • Nakagawa, H.1    Yamanashi, W.S.2    Pitha, J.V.3
  • 18
    • 0029559129 scopus 로고
    • Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the bovine heart
    • Ruffy R, Imran MA, Santel DJ, et al. Radiofrequency delivery through a cooled catheter tip allows the creation of larger endomyocardial lesions in the bovine heart. J Cardiovasc Electrophysiol 1995; 6:1089-1096.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 1089-1096
    • Ruffy, R.1    Imran, M.A.2    Santel, D.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.