메뉴 건너뛰기




Volumn 3, Issue 4, 2003, Pages 175-180

Provision of IMRT in the UK. Part 1: A review of planning, delivery and related technologies

Author keywords

Intensity modulated radiotherapy; Radiotherapy related process and technologies

Indexed keywords

COMPUTER ASSISTED RADIOTHERAPY; IMAGE ANALYSIS; INTENSITY MODULATED RADIATION THERAPY; MEDICAL TECHNOLOGY; PROTON RADIATION; QUALITY CONTROL; RADIOBIOLOGY; RADIOLOGY DEPARTMENT; REVIEW; TREATMENT PLANNING; UNITED KINGDOM;

EID: 31144454792     PISSN: 14603969     EISSN: None     Source Type: Journal    
DOI: 10.1017/S1460396903000529     Document Type: Review
Times cited : (3)

References (33)
  • 1
    • 31144455591 scopus 로고    scopus 로고
    • Provision of IMRT in the UK. Part 2: Current levels, planned expansion and obstacles to implementation
    • Baker C, Hardy V. Provision of IMRT in the UK. Part 2: Current levels, planned expansion and obstacles to implementation. Journal of Radiotherapy in Practice 2003; 3(4): 15-18.
    • (2003) Journal of Radiotherapy in Practice , vol.3 , Issue.4 , pp. 15-18
    • Baker, C.1    Hardy, V.2
  • 3
    • 0036138763 scopus 로고    scopus 로고
    • Optimization of intensity-modulated radiotherapy plans based on the equivalent uniform dose
    • Wu Q, Mohan R, Niemierko A, Schmidt-Ullrich R. Optimization of intensity-modulated radiotherapy plans based on the equivalent uniform dose. Int J Radiat Oncol Biol Phys 2002; 52(1): 224-235.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , Issue.1 , pp. 224-235
    • Wu, Q.1    Mohan, R.2    Niemierko, A.3    Schmidt-Ullrich, R.4
  • 4
    • 0037402518 scopus 로고    scopus 로고
    • Prediction of the benefits from dose-escalated hypofractionated intensity-modulated radiotherapy for prostate cancer
    • Amer AM, Mott J, Mackay RI, et al. Prediction of the benefits from dose-escalated hypofractionated intensity-modulated radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2003; 56(1): 199-207.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , Issue.1 , pp. 199-207
    • Amer, A.M.1    Mott, J.2    Mackay, R.I.3
  • 5
    • 0034036868 scopus 로고    scopus 로고
    • Bioplan: Software for the biological evaluation of radiotherapy treatment plans
    • Sanchez-Nieto B, Nahum AE. Bioplan: Software for the biological evaluation of radiotherapy treatment plans. Med Dosim 2000; 25(2): 71-76.
    • (2000) Med Dosim , vol.25 , Issue.2 , pp. 71-76
    • Sanchez-Nieto, B.1    Nahum, A.E.2
  • 6
    • 0030905738 scopus 로고    scopus 로고
    • Predicting late rectal complications following prostate conformal radiotherapy using biologically effective doses and normalized dose-surface histograms
    • MacKay RI, Hendry JH, Moore CJ, Williams PC, Read G. Predicting late rectal complications following prostate conformal radiotherapy using biologically effective doses and normalized dose-surface histograms. Brit J Radiol 1997; 70: 517-526.
    • (1997) Brit J Radiol , vol.70 , pp. 517-526
    • MacKay, R.I.1    Hendry, J.H.2    Moore, C.J.3    Williams, P.C.4    Read, G.5
  • 7
    • 0035424796 scopus 로고    scopus 로고
    • Incorporating biologic measurements (SF2, CFE) into a tumour control probability model increases their prognostic significance: A study in cervical carcinoma treated with radiation therapy
    • Buffa FM, Davidson SE, Hunter RD, Nahum AE, West CML. Incorporating biologic measurements (SF2, CFE) into a tumour control probability model increases their prognostic significance: A study in cervical carcinoma treated with radiation therapy. Int J Radiat Oncol Biol Phys 2001; 50(5): 1113-1122.
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , Issue.5 , pp. 1113-1122
    • Buffa, F.M.1    Davidson, S.E.2    Hunter, R.D.3    Nahum, A.E.4    West, C.M.L.5
  • 8
    • 0036204888 scopus 로고    scopus 로고
    • Potential improvements in the therapeutic ratio of prostate cancer irradiation: Dose escalation of pathologically identified tumour nodules using intensity modulated radiotherapy
    • Nutting CM, Corbishley CM, Sanchez-Nieto B, Cosgrove VP, Webb S, Dearnaley DP. Potential improvements in the therapeutic ratio of prostate cancer irradiation: Dose escalation of pathologically identified tumour nodules using intensity modulated radiotherapy. Brit J Radiol 2002; 75: 151-161.
    • (2002) Brit J Radiol , vol.75 , pp. 151-161
    • Nutting, C.M.1    Corbishley, C.M.2    Sanchez-Nieto, B.3    Cosgrove, V.P.4    Webb, S.5    Dearnaley, D.P.6
  • 9
    • 0027136115 scopus 로고
    • Implementation of a model for estimating tumour control probability for an inhomogeneously irradiated tumour
    • Niermierko A, Goitein M. Implementation of a model for estimating tumour control probability for an inhomogeneously irradiated tumour. Rad Oncol 1993; 29: 140-147.
    • (1993) Rad Oncol , vol.29 , pp. 140-147
    • Niermierko, A.1    Goitein, M.2
  • 10
    • 0027223126 scopus 로고
    • A model for calculating tumour control probability in radiotherapy including the effects on inhomogeneous distributions of dose and clonogenic cell density
    • Webb S, Nahum AE. A model for calculating tumour control probability in radiotherapy including the effects on inhomogeneous distributions of dose and clonogenic cell density. Phys Med Biol 1993; 38: 653-666.
    • (1993) Phys Med Biol , vol.38 , pp. 653-666
    • Webb, S.1    Nahum, A.E.2
  • 12
    • 0026656051 scopus 로고
    • Tumour and normal tissue responses to fractionated non-uniform dose delivery
    • Kallman P, Ågren A, Brahme A. Tumour and normal tissue responses to fractionated non-uniform dose delivery. Int J Radiat Biol 1992; 62(2): 249-262.
    • (1992) Int J Radiat Biol , vol.62 , Issue.2 , pp. 249-262
    • Kallman, P.1    Ågren, A.2    Brahme, A.3
  • 14
    • 0036804332 scopus 로고    scopus 로고
    • Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: Experience from five radiotherapy departments
    • Esch AV, Bohsung J, Sorvari P, et al. Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique: Experience from five radiotherapy departments. Rad Oncol 2002; 65: 53-70.
    • (2002) Rad Oncol , vol.65 , pp. 53-70
    • Esch, A.V.1    Bohsung, J.2    Sorvari, P.3
  • 15
    • 0035990040 scopus 로고    scopus 로고
    • Investigation of the use of MOSFET for clinical IMRT dosimetric verification
    • Chuang CF, Verhey LJ, Xia P. Investigation of the use of MOSFET for clinical IMRT dosimetric verification. Med Phys 2002; 29(6): 1109-1115.
    • (2002) Med Phys , vol.29 , Issue.6 , pp. 1109-1115
    • Chuang, C.F.1    Verhey, L.J.2    Xia, P.3
  • 16
    • 0030661596 scopus 로고    scopus 로고
    • Planning, delivery and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate
    • Burman C, Chui C-S, Kutcher G, et al. Planning, delivery and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate. Int J Radiat Oncol Biol Phys 1997; 39(4): 863-873.
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , Issue.4 , pp. 863-873
    • Burman, C.1    Chui, C.-S.2    Kutcher, G.3
  • 17
    • 0028857468 scopus 로고
    • The use of an electronic portal imaging device for exit dosimetry and quality control measurements
    • Kirby MC, Williams PC. The use of an electronic portal imaging device for exit dosimetry and quality control measurements. Int J Radiat Oncol Biol Phys 1995; 31(3): 593-603.
    • (1995) Int J Radiat Oncol Biol Phys , vol.31 , Issue.3 , pp. 593-603
    • Kirby, M.C.1    Williams, P.C.2
  • 19
    • 0031037018 scopus 로고    scopus 로고
    • Reporting and analyzing dose distributions: A concept of equivalent uniform dose
    • Niermierko A. Reporting and analyzing dose distributions: A concept of equivalent uniform dose. Med Phys 1997; 24(1): 102-110.
    • (1997) Med Phys , vol.24 , Issue.1 , pp. 102-110
    • Niermierko, A.1
  • 20
    • 0037359870 scopus 로고    scopus 로고
    • Comparing different NTCP models that predict the incidence of radiation pneumonitis
    • Seppenwoolde Y, Lebesque JV, De Jaeger K, et al. Comparing different NTCP models that predict the incidence of radiation pneumonitis. Int J Radiat Oncol Biol Phys 2003; 55(3): 724-735.
    • (2003) Int J Radiat Oncol Biol Phys , vol.55 , Issue.3 , pp. 724-735
    • Seppenwoolde, Y.1    Lebesque, J.V.2    De Jaeger, K.3
  • 21
    • 0035048489 scopus 로고    scopus 로고
    • Impact of dose-distribution uncertainties on rectal NTCP modelling I: Uncertainty estimates
    • Fenwick JD, Nahum AE. Impact of dose-distribution uncertainties on rectal NTCP modelling I: Uncertainty estimates. Med Phys 2000; 28(4): 560-569.
    • (2000) Med Phys , vol.28 , Issue.4 , pp. 560-569
    • Fenwick, J.D.1    Nahum, A.E.2
  • 22
    • 0036534905 scopus 로고    scopus 로고
    • Inclusion of geometric uncertainties in treatment plan evaluation
    • Van Herk M, Remeijer P, Lebesque JV. Inclusion of geometric uncertainties in treatment plan evaluation. Int J Radiat Oncol Biol Phys 2002; 52(5): 1407-1422.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , Issue.5 , pp. 1407-1422
    • Van Herk, M.1    Remeijer, P.2    Lebesque, J.V.3
  • 23
    • 0035064129 scopus 로고    scopus 로고
    • Immobilization devices for intensity-modulated radiation therapy (IMRT)
    • Saw CB, Yakoob R, Enke CA, et al. Immobilization devices for intensity-modulated radiation therapy (IMRT). Med Dosim 2001; 26(1): 71-77.
    • (2001) Med Dosim , vol.26 , Issue.1 , pp. 71-77
    • Saw, C.B.1    Yakoob, R.2    Enke, C.A.3
  • 24
    • 0345269966 scopus 로고    scopus 로고
    • Feasibility of insertion/implanation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumour tracking in radiotherapy
    • Shirato H, Harada T, Harabayashi T, et al. Feasibility of insertion/ implanation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumour tracking in radiotherapy. Int J Radiat Oncol Biol Phys 2003; 56(1): 240-247.
    • (2003) Int J Radiat Oncol Biol Phys , vol.56 , Issue.1 , pp. 240-247
    • Shirato, H.1    Harada, T.2    Harabayashi, T.3
  • 26
    • 0035989949 scopus 로고    scopus 로고
    • A performance comparison of flat-panel imager-based MV and kV cone-beam CT
    • Groh BA, Siewerdsen JH, Drake DG, Wong JW, Jaffray DA. A performance comparison of flat-panel imager-based MV and kV cone-beam CT. Med Phys 2002; 29(6): 967-975.
    • (2002) Med Phys , vol.29 , Issue.6 , pp. 967-975
    • Groh, B.A.1    Siewerdsen, J.H.2    Drake, D.G.3    Wong, J.W.4    Jaffray, D.A.5
  • 28
    • 0027141318 scopus 로고
    • Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapy
    • Mackie TR, Holmes T, Swerdloff S, et al. Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapy. Med Phys 1993; 20: 1709-1719.
    • (1993) Med Phys , vol.20 , pp. 1709-1719
    • Mackie, T.R.1    Holmes, T.2    Swerdloff, S.3
  • 29
    • 0030869676 scopus 로고    scopus 로고
    • Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region
    • Verellen D, Linthout N, Van Den Berge D, Bel A, Storme G. Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region. Int J Radiat Oncol Biol Phys 1997; 39(1): 99-114.
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , Issue.1 , pp. 99-114
    • Verellen, D.1    Linthout, N.2    Van Den Berge, D.3    Bel, A.4    Storme, G.5
  • 30
    • 0037152480 scopus 로고    scopus 로고
    • Inverse planning for functional image-guided intensity-modulated radiation therapy
    • Xing L, Cotrutz C, Hunjan S, Boyer AL, Adalsteinsson E, Spielman D. Inverse planning for functional image-guided intensity-modulated radiation therapy. Phys Med Biol 2002; 47(20): 3567-3578.
    • (2002) Phys Med Biol , vol.47 , Issue.20 , pp. 3567-3578
    • Xing, L.1    Cotrutz, C.2    Hunjan, S.3    Boyer, A.L.4    Adalsteinsson, E.5    Spielman, D.6
  • 31
    • 0037305953 scopus 로고    scopus 로고
    • What can we expect from dose escalation using proton beams?
    • Fowler JF. What can we expect from dose escalation using proton beams? Clin Onc 2003; 15: S10-S15.
    • (2003) Clin Onc , vol.15
    • Fowler, J.F.1
  • 33


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.