Volumn 88, Issue 10, 2005, Pages 1362-1366

Comparison of anterior chamber depth in healthy myopic Thai eye using orbscan and ultrasound

Author keywords

Anterior chamber depth; Orbscan; Ultrasound

Indexed keywords

ADULT; ANTERIOR EYE CHAMBER; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION COEFFICIENT; FEMALE; HUMAN; INTERMETHOD COMPARISON; LINEAR REGRESSION ANALYSIS; MALE; MEDICAL ASSESSMENT; MYOPIA; OPTICAL COHERENCE TOMOGRAPHY; OPTOMETRY; STATISTICAL SIGNIFICANCE; STUDENT T TEST;

EID: 30844440784     PISSN: 01252208     EISSN: 01252208     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (20)
  • 1
    • 0027276169 scopus 로고
    • Refractive power calculations for intraocular lenses in the phakic eye
    • Holladay JT. Refractive power calculations for intraocular lenses in the phakic eye. Am J Ophthalmol 1993; 116: 63-6.
    • (1993) Am J Ophthalmol , vol.116 , pp. 63-66
    • Holladay, J.T.1
  • 2
    • 0030919955 scopus 로고    scopus 로고
    • Refractive surgery, optical aberrations, and visual performance
    • Applegate RA, Howland HC. Refractive surgery, optical aberrations, and visual performance. J Refract Surg 1997; 13: 295-9.
    • (1997) J Refract Surg , vol.13 , pp. 295-299
    • Applegate, R.A.1    Howland, H.C.2
  • 3
    • 0033820671 scopus 로고    scopus 로고
    • Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant
    • Vetrugno M, Cardascia N, Cardia L. Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant. Br J Ophthalmol 2000; 84: 1113-6.
    • (2000) Br J Ophthalmol , vol.84 , pp. 1113-1116
    • Vetrugno, M.1    Cardascia, N.2    Cardia, L.3
  • 4
    • 0027181334 scopus 로고
    • Comparison of efficacy of longest, average, and shortest axial length measurements with a solid-tip ultrasound probe in predicting intraocular lens power
    • Murphy GE, Murphy CG. Comparison of efficacy of longest, average, and shortest axial length measurements with a solid-tip ultrasound probe in predicting intraocular lens power. J Cataract Refract Surg 1993; 19: 644-5.
    • (1993) J Cataract Refract Surg , vol.19 , pp. 644-645
    • Murphy, G.E.1    Murphy, C.G.2
  • 6
    • 0035161383 scopus 로고    scopus 로고
    • Comparison of corneal thickness measurements using ultrasound and Orbscan slitscanning topography in normal and post-LASIK eyes
    • Chakrabarti HS, Craig JP, Brahma A, Malik TY, McGhee CNJ. Comparison of corneal thickness measurements using ultrasound and Orbscan slitscanning topography in normal and post-LASIK eyes. J Cataract Refract Surg 2001; 27: 1823-8.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1823-1828
    • Chakrabarti, H.S.1    Craig, J.P.2    Brahma, A.3    Malik, T.Y.4    McGhee, C.N.J.5
  • 7
    • 0028641147 scopus 로고
    • Anterior chamber depth after posterior chamber intraocular lens implantation
    • Arai M, Ohzuno I, Zako M. Anterior chamber depth after posterior chamber intraocular lens implantation. Acta Ophthalmol 1994; 72: 694-7.
    • (1994) Acta Ophthalmol , vol.72 , pp. 694-697
    • Arai, M.1    Ohzuno, I.2    Zako, M.3
  • 8
    • 0029028130 scopus 로고
    • Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm
    • Olsen T, Corydon L, Gimbel H. Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm. J Cataract Refract Surg 1995; 21: 313-9.
    • (1995) J Cataract Refract Surg , vol.21 , pp. 313-319
    • Olsen, T.1    Corydon, L.2    Gimbel, H.3
  • 9
    • 0031764917 scopus 로고    scopus 로고
    • Refractive and visual outcome of hyperopic cataract cases operated on before and after implementation of the Holladay II formula
    • Fenzl RE, Gills JP, Cherchio M. Refractive and visual outcome of hyperopic cataract cases operated on before and after implementation of the Holladay II formula. Ophthalmology 1998; 105: 1759-64.
    • (1998) Ophthalmology , vol.105 , pp. 1759-1764
    • Fenzl, R.E.1    Gills, J.P.2    Cherchio, M.3
  • 10
    • 0029938588 scopus 로고    scopus 로고
    • Achieving emmetropia in extremely short eyes with two piggyback posterior chamber intraocular lenses
    • Holladay JT, Gills JP, Leidlein J, Cherchio M. Achieving emmetropia in extremely short eyes with two piggyback posterior chamber intraocular lenses. Ophthalmology 1996; 103: 1118-23.
    • (1996) Ophthalmology , vol.103 , pp. 1118-1123
    • Holladay, J.T.1    Gills, J.P.2    Leidlein, J.3    Cherchio, M.4
  • 13
    • 0029900125 scopus 로고    scopus 로고
    • Increase in iris-lens contact after laser iridotomy for pupillary block angle closure
    • Caronia RM, Liebmann JM, Stegman Z, Sokol J, Ritch R. Increase in iris-lens contact after laser iridotomy for pupillary block angle closure. Am J Ophthalmol 1996; 112: 53-7.
    • (1996) Am J Ophthalmol , vol.112 , pp. 53-57
    • Caronia, R.M.1    Liebmann, J.M.2    Stegman, Z.3    Sokol, J.4    Ritch, R.5
  • 14
    • 0036678051 scopus 로고    scopus 로고
    • Phakic intraocular lenses and refractory lensectomy for myopia
    • O'Brien TP, Awwad ST. Phakic intraocular lenses and refractory lensectomy for myopia. Curr Opin Ophthalmol 2002; 13:264-70.
    • (2002) Curr Opin Ophthalmol , vol.13 , pp. 264-270
    • O'Brien, T.P.1    Awwad, S.T.2
  • 18
    • 0004257968 scopus 로고    scopus 로고
    • Baltimore: Williams & Wilkins
    • th ed. Baltimore: Williams & Wilkins; 1997: 179.
    • (1997) th Ed. , pp. 179
    • Shields, M.B.1
  • 19
    • 0025336954 scopus 로고
    • Comparison of A-scan device accuracy
    • Giers U, Epple C. Comparison of A-scan device accuracy. J Cataract Refract Surg 1990; 16: 235-42.
    • (1990) J Cataract Refract Surg , vol.16 , pp. 235-242
    • Giers, U.1    Epple, C.2
  • 20
    • 0036169561 scopus 로고    scopus 로고
    • Anterior chamber depth measurement: A-scan versus optical methods
    • Koranyi G, Lydahl E, Norrby S, Taube M. Anterior chamber depth measurement: A-scan versus optical methods. J Cataract Refract Surg 2002; 28: 243-7.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 243-247
    • Koranyi, G.1    Lydahl, E.2    Norrby, S.3    Taube, M.4