메뉴 건너뛰기




Volumn 35, Issue 8, 2004, Pages 791-798

Outcome after surgery for Maisonneuve fracture of the fibula

Author keywords

Ankle mortise; Arthrosis; Diastasis; Fibular length; Surgery; Syndesmosis; Talar tilt

Indexed keywords

ADULT; ANKLE; ANKLE FRACTURE; ANKLE PAIN; BONE SCREW; CLINICAL ARTICLE; CLINICAL EXAMINATION; DEVICE REMOVAL; FEMALE; FIBULA; FIBULA FRACTURE; FLUOROSCOPY; FOLLOW UP; FOOT RADIOGRAPHY; FRACTURE REDUCTION; FUNCTIONAL ASSESSMENT; HUMAN; JOINT MOBILITY; LOCAL ANESTHESIA; MALE; OSTEOARTHRITIS; PATIENT SATISFACTION; PRIORITY JOURNAL; REVIEW; SCORING SYSTEM; SPORT INJURY; TIBIA; TREATMENT OUTCOME;

EID: 3042715447     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0020-1383(03)00155-4     Document Type: Article
Times cited : (51)

References (26)
  • 1
    • 0025784686 scopus 로고
    • Osteolytic changes accompanying degradation of absorbable fracture fixation implants
    • Bostman O.M. Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J. Bone Joint Surg. Br. 73(4):1991;679-682
    • (1991) J. Bone Joint Surg. Br. , vol.73 , Issue.4 , pp. 679-682
    • Bostman, O.M.1
  • 2
    • 0026518970 scopus 로고
    • Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures
    • Bostman O.M. Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin. Orthop. 278:1992;193-199
    • (1992) Clin. Orthop. , vol.278 , pp. 193-199
    • Bostman, O.M.1
  • 3
    • 0027510283 scopus 로고
    • Distal tibiofibular synostosis after malleolar fractures treated using absorbable implants
    • Bostman O.M. Distal tibiofibular synostosis after malleolar fractures treated using absorbable implants. Foot Ankle. 14(1):1993;38-43
    • (1993) Foot Ankle , vol.14 , Issue.1 , pp. 38-43
    • Bostman, O.M.1
  • 4
    • 0024597237 scopus 로고
    • Ankle fractures treated using biodegradable internal fixation
    • Bostman O.M., Hirvensalo E., Vainionpaa S., et al. Ankle fractures treated using biodegradable internal fixation. Clin. Orthop. 238:1989;195-203
    • (1989) Clin. Orthop. , vol.238 , pp. 195-203
    • Bostman, O.M.1    Hirvensalo, E.2    Vainionpaa, S.3
  • 6
    • 0021853617 scopus 로고
    • Results of the displaced external rotation-abduction fracture of the ankle
    • De Souza L.J., Gustilo R.B., Meyer T.J. Results of the displaced external rotation-abduction fracture of the ankle. J. Bone Joint Surg. Am. 67(7):1985;1066-1074
    • (1985) J. Bone Joint Surg. Am. , vol.67 , Issue.7 , pp. 1066-1074
    • De Souza, L.J.1    Gustilo, R.B.2    Meyer, T.J.3
  • 8
    • 0024840321 scopus 로고
    • A radiographic evaluation of the tibiofibular syndesmosis
    • Harper M.C., Keller T.S. A radiographic evaluation of the tibiofibular syndesmosis. Foot Ankle. 10(3):1989;156-160
    • (1989) Foot Ankle , vol.10 , Issue.3 , pp. 156-160
    • Harper, M.C.1    Keller, T.S.2
  • 9
    • 30344442497 scopus 로고    scopus 로고
    • Biogradable screw fixation of the syndesmosis together with metallic osteosynthesis, Preliminary experience of 7 ankles
    • Korkala O., Kiljunen V., Salminen S., et al. Biogradable screw fixation of the syndesmosis together with metallic osteosynthesis, Preliminary experience of 7 ankles. Ann. Chir. Gynaecol. 88(4):1999;295-297
    • (1999) Ann. Chir. Gynaecol. , vol.88 , Issue.4 , pp. 295-297
    • Korkala, O.1    Kiljunen, V.2    Salminen, S.3
  • 10
    • 84873760557 scopus 로고
    • Fractures of the ankle. II. Combined experimental-surgical and experimental-roentgenologic investigation
    • Lauge-Hansen N. Fractures of the ankle. II. Combined experimental- surgical and experimental-roentgenologic investigation. Arch. Surg. 60:1950;957-985
    • (1950) Arch. Surg. , vol.60 , pp. 957-985
    • Lauge-Hansen, N.1
  • 11
    • 0023219765 scopus 로고
    • Maisonneuve fracture: Case report of a missed diagnosis
    • Lock T.R., Schaffer J.J., Manoli A. Maisonneuve fracture: case report of a missed diagnosis. Ann. Emerg. Med. 16:1987;805-807
    • (1987) Ann. Emerg. Med. , vol.16 , pp. 805-807
    • Lock, T.R.1    Schaffer, J.J.2    Manoli, A.3
  • 12
    • 0000762192 scopus 로고
    • Recherches sur la fracture du perone
    • Maisonneuve M.J.G. Recherches sur la fracture du perone. Arch. Gen. Med. 7:1840;165-187
    • (1840) Arch. Gen. Med. , vol.7 , pp. 165-187
    • Maisonneuve, M.J.G.1
  • 13
    • 0019308345 scopus 로고
    • A reproducible approach to the internal fixation of adult ankle fractures: Rationale, technique and early results
    • Mast J.W., Teipner W.A. A reproducible approach to the internal fixation of adult ankle fractures: rationale, technique and early results. Orthop. Clin. North Am. 11:1980;661-679
    • (1980) Orthop. Clin. North Am. , vol.11 , pp. 661-679
    • Mast, J.W.1    Teipner, W.A.2
  • 14
    • 0030978357 scopus 로고    scopus 로고
    • Syndesmotic screw placement: A biomechanical analysis
    • McBryde A., Chiasson B., Wilhelm A., et al. Syndesmotic screw placement: a biomechanical analysis. Foot Ankle Int. 18(5):1997;262-266
    • (1997) Foot Ankle Int. , vol.18 , Issue.5 , pp. 262-266
    • McBryde, A.1    Chiasson, B.2    Wilhelm, A.3
  • 15
    • 0027474357 scopus 로고
    • The Maisonneuve fracture of the fibula
    • Merril K.D. The Maisonneuve fracture of the fibula. Clin. Orthop. 287:1993;218-223
    • (1993) Clin. Orthop. , vol.287 , pp. 218-223
    • Merril, K.D.1
  • 16
    • 0032621010 scopus 로고    scopus 로고
    • Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis: A biomechanical study
    • Miller R.S., Weinhold P.S., Dahners L.E. Comparison of tricortical screw fixation versus a modified suture construct for fixation of ankle syndesmosis: a biomechanical study. J. Orthop. Trauma. 13(1):1999;39-42
    • (1999) J. Orthop. Trauma. , vol.13 , Issue.1 , pp. 39-42
    • Miller, R.S.1    Weinhold, P.S.2    Dahners, L.E.3
  • 18
    • 0032191868 scopus 로고    scopus 로고
    • Percutaneous fixation of Maisonneuve and Maisonneuve-type fractures: A minimally invasive approach
    • Obeid E.M., Amr M., Hirst P., Paul A.S. Percutaneous fixation of Maisonneuve and Maisonneuve-type fractures: a minimally invasive approach. Injury. 29(8):1998;619-622
    • (1998) Injury , vol.29 , Issue.8 , pp. 619-622
    • Obeid, E.M.1    Amr, M.2    Hirst, P.3    Paul, A.S.4
  • 19
    • 0017110832 scopus 로고
    • Maisonneuve fracture of the fibula
    • Pankovich A.M. Maisonneuve fracture of the fibula. J. Bone Joint Surg. Am. 58:1976;337-342
    • (1976) J. Bone Joint Surg. Am. , vol.58 , pp. 337-342
    • Pankovich, A.M.1
  • 20
    • 0017233865 scopus 로고
    • Changes in tibiotalar area of contact caused by lateral talar shift
    • Ramsey P.L., Hamilton W. Changes in tibiotalar area of contact caused by lateral talar shift. J. Bone Joint Surg. Am. 58:1976;356-357
    • (1976) J. Bone Joint Surg. Am. , vol.58 , pp. 356-357
    • Ramsey, P.L.1    Hamilton, W.2
  • 21
    • 0343353899 scopus 로고    scopus 로고
    • Bioabsorbable fixation in orthopaedic surgery and traumatology
    • Rokkanen P.U., Bostman O.M., Hirvensalo E., et al. Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials. 21(24):2000;2607-2613
    • (2000) Biomaterials , vol.21 , Issue.24 , pp. 2607-2613
    • Rokkanen, P.U.1    Bostman, O.M.2    Hirvensalo, E.3
  • 22
    • 0029986978 scopus 로고    scopus 로고
    • Absorbable devices in the fixation of fractures
    • Rokkanen P.U., Bostman O.M., Vainionpaa S. Absorbable devices in the fixation of fractures. J. Trauma. 40(3):1996;123-127
    • (1996) J. Trauma , vol.40 , Issue.3 , pp. 123-127
    • Rokkanen, P.U.1    Bostman, O.M.2    Vainionpaa, S.3
  • 23
    • 0033623160 scopus 로고    scopus 로고
    • Biomechanical comparison of syndesmosis fixation with 3.5 mm and 4.5 mm stainless steel screws
    • Thompson M.C., Gesink D.S. Biomechanical comparison of syndesmosis fixation with 3.5 mm and 4.5 mm stainless steel screws. Foot Ankle Int. 21(9):2000;736-741
    • (2000) Foot Ankle Int. , vol.21 , Issue.9 , pp. 736-741
    • Thompson, M.C.1    Gesink, D.S.2
  • 24
    • 0035031197 scopus 로고    scopus 로고
    • Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: A prospective randomized trial
    • Thordarson D.B., Samuelson M., Shepherd L.E., et al. Bioabsorbable versus stainless steel screw fixation of the syndesmosis in pronation-lateral rotation ankle fractures: a prospective randomized trial. Foot Ankle Int. 22(4):2001;335-338
    • (2001) Foot Ankle Int. , vol.22 , Issue.4 , pp. 335-338
    • Thordarson, D.B.1    Samuelson, M.2    Shepherd, L.E.3
  • 25
    • 0028999384 scopus 로고
    • The tibiofibular syndesmosis. Evaluation of the ligamentous structures, methods of fixation and radiographic assessment
    • Xenos J.S., Hopkinson W.J., Mulligan M.E., Olson E.J. The tibiofibular syndesmosis. Evaluation of the ligamentous structures, methods of fixation and radiographic assessment. J. Bone Joint Surg. Am. 77(6):1995;847-856
    • (1995) J. Bone Joint Surg. Am. , vol.77 , Issue.6 , pp. 847-856
    • Xenos, J.S.1    Hopkinson, W.J.2    Mulligan, M.E.3    Olson, E.J.4
  • 26
    • 3042762264 scopus 로고
    • Ankle instability associated with fractures of the fibular shaft
    • Yablin IG, Segal D, Leach R, editors.
    • Yablon IG, Segal D. Ankle instability associated with fractures of the fibular shaft. In: Yablin IG, Segal D, Leach R, editors. Ankle injuries. 1st ed. 1983. p. 95.
    • (1983) Ankle Injuries. 1st Ed. , pp. 95
    • Yablon, I.G.1    Segal, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.