-
1
-
-
0021842535
-
Biodegradable implants in fracture fixations: Early results of treatment of fractures of the ankle
-
Rokkanen P, Böstman O, Vainionpää S, Vihtonen K, Törmänen P, Laiho J, Kilpikari J, Tamminmäki M: Biodegradable implants in fracture fixations: early results of treatment of fractures of the ankle. Lancet 1 (8443): 1422-1424, 1985
-
(1985)
Lancet
, vol.1
, Issue.8443
, pp. 1422-1424
-
-
Rokkanen, P.1
Böstman, O.2
Vainionpää, S.3
Vihtonen, K.4
Törmänen, P.5
Laiho, J.6
Kilpikari, J.7
Tamminmäki, M.8
-
2
-
-
0026497098
-
Self-reinforced absorbable screws in the fixation of displaced ankle fractures: A prospective clinical study of 152 patients
-
Partio EK, Böstman O, Hirvensalo E, Vainionpää S, Vihtonen K, Pätiälä H, Törmälä P, Rokkanen P: Self-reinforced absorbable screws in the fixation of displaced ankle fractures: A prospective clinical study of 152 patients. J Orthop Trauma 6: 209-215, 1992
-
(1992)
J Orthop Trauma
, vol.6
, pp. 209-215
-
-
Partio, E.K.1
Böstman, O.2
Hirvensalo, E.3
Vainionpää, S.4
Vihtonen, K.5
Pätiälä, H.6
Törmälä, P.7
Rokkanen, P.8
-
3
-
-
0028277347
-
Biodegradable fixation of ankle fractures. A roentgen spectrophotogrammetric study of 32 cases
-
Ahl T, Lundberg N, Wykman A: Biodegradable fixation of ankle fractures. A roentgen spectrophotogrammetric study of 32 cases. Acta Orthop Scand 65: 166-170, 1994
-
(1994)
Acta Orthop Scand
, vol.65
, pp. 166-170
-
-
Ahl, T.1
Lundberg, N.2
Wykman, A.3
-
4
-
-
0030451979
-
Fractures of the ankle and of the distal part of the tibia
-
Griend RV, Michelson JD, Bone LB: Fractures of the ankle and of the distal part of the tibia. J Bone Joint Surg 78-A: 1772-1783, 1996
-
(1996)
J Bone Joint Surg
, vol.78 A
, pp. 1772-1783
-
-
Griend, R.V.1
Michelson, J.D.2
Bone, L.B.3
-
5
-
-
0028852598
-
Current concept review. Fractures about the ankle
-
Michelson JD: Current concept review. Fractures about the ankle. J Bone Joint Surg 77-A: 142-152, 1995
-
(1995)
J Bone Joint Surg
, vol.77 A
, pp. 142-152
-
-
Michelson, J.D.1
-
6
-
-
0026583096
-
Foreign body reactions to polyglycolide screws. Observations in 24/216 malleolar fracture cases
-
Böstman O, Partio E, Hirvensalo E, Rokkanen P: Foreign body reactions to polyglycolide screws. Observations in 24/216 malleolar fracture cases. Acta Orthop Scand 63: 173-176, 1992
-
(1992)
Acta Orthop Scand
, vol.63
, pp. 173-176
-
-
Böstman, O.1
Partio, E.2
Hirvensalo, E.3
Rokkanen, P.4
-
7
-
-
29944433512
-
Bioabsorbable fixation devices in orthopaedics and traumatology. Current review
-
Rokkanen P: Bioabsorbable fixation devices in orthopaedics and traumatology. Current review. Ann Chir Gyn 87: 13-20, 1998
-
(1998)
Ann Chir Gyn
, vol.87
, pp. 13-20
-
-
Rokkanen, P.1
-
8
-
-
0030059538
-
Metallic or absorbable implants for ankle fractures
-
Sinisaari I, Pätiälä H, Böstman O, Mäkelä EA, Hirvensalo E, Partio EK, Törmälä P, Rokkanen P: Metallic or absorbable implants for ankle fractures. Acta Orthop Scand 67: 16-18, 1996
-
(1996)
Acta Orthop Scand
, vol.67
, pp. 16-18
-
-
Sinisaari, I.1
Pätiälä, H.2
Böstman, O.3
Mäkelä, E.A.4
Hirvensalo, E.5
Partio, E.K.6
Törmälä, P.7
Rokkanen, P.8
-
9
-
-
0031706443
-
Fixation of the ankle syndesmosis with bioabsorbable screws
-
Thordarson DB: Fixation of the ankle syndesmosis with bioabsorbable screws. Techniques in Orthopaedics 13: 187-191, 1998
-
(1998)
Techniques in Orthopaedics
, vol.13
, pp. 187-191
-
-
Thordarson, D.B.1
-
10
-
-
0031654543
-
Fixation of ankle fractures with biodegradable implants
-
Melamed EA, Seligson D: Fixation of ankle fractures with biodegradable implants. Techniques in Orthopaedics 13:192-200, 1998
-
(1998)
Techniques in Orthopaedics
, vol.13
, pp. 192-200
-
-
Melamed, E.A.1
Seligson, D.2
|