메뉴 건너뛰기




Volumn 113, Issue 6, 2004, Pages 353-359

D-Dimer as marker for microcirculatory failure: Correlation with LOD and APACHE II scores

Author keywords

D Dimer levels; Microcirculatory failure; Thromboembolic disease

Indexed keywords

D DIMER;

EID: 3042600901     PISSN: 00493848     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.thromres.2004.03.013     Document Type: Article
Times cited : (17)

References (24)
  • 3
    • 0029782755 scopus 로고    scopus 로고
    • The Logistic Organ Dysfunction system. A new way to assess organ dysfunction in the intensive care unit. ICU Scoring Group
    • Sep. 11
    • Le Gall J.R., Klar J., Lemeshow S., Saulnier F., Alberti C., Artigas A., et al. The Logistic Organ Dysfunction system. A new way to assess organ dysfunction in the intensive care unit. ICU Scoring Group. JAMA. 276(10):1996 (Sep. 11);802-810
    • (1996) JAMA , vol.276 , Issue.10 , pp. 802-810
    • Le Gall, J.R.1    Klar, J.2    Lemeshow, S.3    Saulnier, F.4    Alberti, C.5    Artigas, A.6
  • 4
    • 0029161001 scopus 로고
    • Pooled patient samples as reference material for D-dimer
    • Adema E., Berbert U. Pooled patient samples as reference material for D-dimer. Thromb. Res. 80:1995;85-88
    • (1995) Thromb. Res. , vol.80 , pp. 85-88
    • Adema, E.1    Berbert, U.2
  • 6
    • 0018190174 scopus 로고
    • Antithrombin III: Critical review of assay methods. Significance of variations in health and disease
    • Odegard O., Abildgaard U. Antithrombin III: critical review of assay methods. Significance of variations in health and disease. Hemostasis. 7:1978;127-134
    • (1978) Hemostasis , vol.7 , pp. 127-134
    • Odegard, O.1    Abildgaard, U.2
  • 7
    • 0030870378 scopus 로고    scopus 로고
    • Fibrin detected in plasma of patients with disseminated intravascular coagulation by fibrin-specific antibodies consists primarily of high molecular weight factor XIIIa-crosslinked and plasmin-modified complexes partially containing fibrinopeptide
    • Pfitzner S.A., Dempfle C.E., Matsuda M., Heene D.L. Fibrin detected in plasma of patients with disseminated intravascular coagulation by fibrin-specific antibodies consists primarily of high molecular weight factor XIIIa-crosslinked and plasmin-modified complexes partially containing fibrinopeptide. Thromb. Haemost. 78:1997;1069-1078
    • (1997) Thromb. Haemost. , vol.78 , pp. 1069-1078
    • Pfitzner, S.A.1    Dempfle, C.E.2    Matsuda, M.3    Heene, D.L.4
  • 8
    • 0027448761 scopus 로고
    • Clinical evaluation of D-dimer testing in disseminated intravascular coagulation
    • Fukutake K., Kuroso K., Isogai N., Shinozawa K. Clinical evaluation of D-dimer testing in disseminated intravascular coagulation. Fibrinolysis. 7S2:1993;10-22
    • (1993) Fibrinolysis , vol.72 , pp. 10-22
    • Fukutake, K.1    Kuroso, K.2    Isogai, N.3    Shinozawa, K.4
  • 9
    • 7344253585 scopus 로고    scopus 로고
    • D-Dimer testing as an adjunct to ultrasonography in patients with clinically suspected deep vein thrombosis: Prospective cohort study
    • Bernardi E., Prandoni P., Lensing A.W.A., Agnelli G., Guazzaloca G., Scannapieco G., et al. D-Dimer testing as an adjunct to ultrasonography in patients with clinically suspected deep vein thrombosis: prospective cohort study. BMJ. 317:1998;1037-1040
    • (1998) BMJ , vol.317 , pp. 1037-1040
    • Bernardi, E.1    Prandoni, P.2    Lensing, A.W.A.3    Agnelli, G.4    Guazzaloca, G.5    Scannapieco, G.6
  • 10
    • 0031974827 scopus 로고    scopus 로고
    • Dimer strategy in thrombosis exclusion. A gold standard study in 100 patients suspected of deep venous thrombosis or pulmonary embolism: 8 DD methods compared
    • Freyburger G., Trillaud H., Labrouche S., Gauthier P., Javorschi S., Bernard P., et al. Dimer strategy in thrombosis exclusion. A gold standard study in 100 patients suspected of deep venous thrombosis or pulmonary embolism: 8 DD methods compared. Thromb. Haemost. 79:1998;32-37
    • (1998) Thromb. Haemost. , vol.79 , pp. 32-37
    • Freyburger, G.1    Trillaud, H.2    Labrouche, S.3    Gauthier, P.4    Javorschi, S.5    Bernard, P.6
  • 11
    • 0030614846 scopus 로고    scopus 로고
    • Reliability of five rapid D-dimer assays compared to ELISA in the exclusion of deep venous thrombosis
    • Janssen M.C.H., Heebels A.E., Metz M., Verbruggen H., Wollersheim H., Janssen S., et al. Reliability of five rapid D-dimer assays compared to ELISA in the exclusion of deep venous thrombosis. Thromb. Haemost. 77:1997;262-266
    • (1997) Thromb. Haemost. , vol.77 , pp. 262-266
    • Janssen, M.C.H.1    Heebels, A.E.2    Metz, M.3    Verbruggen, H.4    Wollersheim, H.5    Janssen, S.6
  • 12
    • 0029876674 scopus 로고    scopus 로고
    • Disseminated intravascular coagulation is a frequent complication of systemic inflammatory response syndrome
    • Gando S., Kameue T., Nanzaki S., Nakanishi Y. Disseminated intravascular coagulation is a frequent complication of systemic inflammatory response syndrome. Thromb. Haemost. 75:1996;224-228
    • (1996) Thromb. Haemost. , vol.75 , pp. 224-228
    • Gando, S.1    Kameue, T.2    Nanzaki, S.3    Nakanishi, Y.4
  • 13
    • 0031799278 scopus 로고    scopus 로고
    • A rapid assay for the detection of circulating D-dimer is associated with clinical outcomes among critically ill patients
    • Kollef M.H., Eisenberg P.R., Shannon W. A rapid assay for the detection of circulating D-dimer is associated with clinical outcomes among critically ill patients. Crit. Care Med. 26:1998;1054-1060
    • (1998) Crit. Care Med. , vol.26 , pp. 1054-1060
    • Kollef, M.H.1    Eisenberg, P.R.2    Shannon, W.3
  • 14
    • 0029942462 scopus 로고    scopus 로고
    • Quantification of leukocyte elastase and cathepsin G in plasma by a simple method: Effect of elastase in plasma levels of D-dimer and thrombomodulin
    • Nagamatsu Y., Fukada A., Yamamoto J., Tsuda Y., Okada Y. Quantification of leukocyte elastase and cathepsin G in plasma by a simple method: effect of elastase in plasma levels of D-dimer and thrombomodulin. Clin. Lab. Haematol. 18:1996;29-34
    • (1996) Clin. Lab. Haematol. , vol.18 , pp. 29-34
    • Nagamatsu, Y.1    Fukada, A.2    Yamamoto, J.3    Tsuda, Y.4    Okada, Y.5
  • 15
    • 0032213861 scopus 로고    scopus 로고
    • Degradation of fibrinogen and cross-linked fibrin by human neutrophil elastase generates D-like fragments detected by ELISA but not latex D-dimer test
    • Bach-Gansmo E.T., Godal H.C., Skjonsberg O.H. Degradation of fibrinogen and cross-linked fibrin by human neutrophil elastase generates D-like fragments detected by ELISA but not latex D-dimer test. Thromb. Res. 92:1998;125-134
    • (1998) Thromb. Res. , vol.92 , pp. 125-134
    • Bach-Gansmo, E.T.1    Godal, H.C.2    Skjonsberg, O.H.3
  • 16
    • 0033060172 scopus 로고    scopus 로고
    • D-dimer assay predicts mortality in critically ill patients without disseminated intravascular coagulation or venous thromboembolic disease
    • Shorr A.F., Trotta R.F., Alkins S.A., Hanzel G.S., Diehl L.F. D-dimer assay predicts mortality in critically ill patients without disseminated intravascular coagulation or venous thromboembolic disease. Intensive Care Med. 25:1999;207-210
    • (1999) Intensive Care Med. , vol.25 , pp. 207-210
    • Shorr, A.F.1    Trotta, R.F.2    Alkins, S.A.3    Hanzel, G.S.4    Diehl, L.F.5
  • 18
    • 17444375639 scopus 로고    scopus 로고
    • Sensitivity and Specificity of a whole-blood assay for D-dimer in the diagnosis of pulmonary embolism
    • Ginsberg J.S., Wells P.S., Kearon C., Anderson D., Crowther M., Weitz J.I., et al. Sensitivity and Specificity of a whole-blood assay for D-dimer in the diagnosis of pulmonary embolism. Ann. Intern. Med. 129:1998;1006-1011
    • (1998) Ann. Intern. Med. , vol.129 , pp. 1006-1011
    • Ginsberg, J.S.1    Wells, P.S.2    Kearon, C.3    Anderson, D.4    Crowther, M.5    Weitz, J.I.6
  • 20
    • 0031822215 scopus 로고    scopus 로고
    • Disseminated intravascular coagulation: Clinical and laboratory aspects
    • Carey M.J., Rodgers G.M. Disseminated intravascular coagulation: clinical and laboratory aspects. Am. J. Hematol. 59:1998;65-73
    • (1998) Am. J. Hematol. , vol.59 , pp. 65-73
    • Carey, M.J.1    Rodgers, G.M.2
  • 21
    • 0026780957 scopus 로고
    • Diagnostic efficacy of the D-dimer assay in disseminated intravascular coagulation (DIC)
    • Bick R.L., Baker W.F. Diagnostic efficacy of the D-dimer assay in disseminated intravascular coagulation (DIC). Thromb. Res. 65:1992;785-790
    • (1992) Thromb. Res. , vol.65 , pp. 785-790
    • Bick, R.L.1    Baker, W.F.2
  • 22
    • 0028211703 scopus 로고
    • Disseminated intravascular coagulation. Objective criteria for diagnosis and management
    • Bick R.L. Disseminated intravascular coagulation. Objective criteria for diagnosis and management. Med. Clin. N. Am. 78:1994;511-543
    • (1994) Med. Clin. N. Am. , vol.78 , pp. 511-543
    • Bick, R.L.1
  • 23
    • 0342595490 scopus 로고
    • Laboratory diagnosis of DIC
    • Faulkner W.R. Laboratory diagnosis of DIC. Lab. Reput. 17:1995;1-5
    • (1995) Lab. Reput. , vol.17 , pp. 1-5
    • Faulkner, W.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.