메뉴 건너뛰기




Volumn 5368, Issue 2, 2004, Pages 696-704

A method to measure the presampling MTF using a novel edge test device and algorithm

Author keywords

Digital radiography; Edge; Edge spread function (ESF); Image quality; Line spread function (LSF); Modulation transfer function (MTF); Resolution; Slit

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; FAST FOURIER TRANSFORMS; FREQUENCIES; IMAGE QUALITY; IMAGING TECHNIQUES; OPTICAL RESOLVING POWER; QUALITY ASSURANCE; RADIOGRAPHY; TUNGSTEN;

EID: 3042589234     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.534051     Document Type: Conference Paper
Times cited : (11)

References (11)
  • 1
    • 0021253653 scopus 로고
    • Investigation of basic imaging properties in digital radiography. 1. Modulation transfer function
    • M. L. Giger and K. Doi, "Investigation of basic imaging properties in digital radiography. 1. Modulation transfer function", Medical Physics 11(3), pp.287-295, 1984.
    • (1984) Medical Physics , vol.11 , Issue.3 , pp. 287-295
    • Giger, M.L.1    Doi, K.2
  • 4
    • 0032800112 scopus 로고    scopus 로고
    • Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors
    • K. Stierstorfer and M. Spahn, "Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors", Medical Physics 26(7), pp.1312-1319, 1999.
    • (1999) Medical Physics , vol.26 , Issue.7 , pp. 1312-1319
    • Stierstorfer, K.1    Spahn, M.2
  • 5
    • 0023577511 scopus 로고
    • A method for modulation transfer function determination from edge profiles with correction for finite-element differentiation
    • I. A. Cunningham and A. Fenster, "A method for modulation transfer function determination from edge profiles with correction for finite-element differentiation", Medical Physics 14(4), pp.533-537, 1987.
    • (1987) Medical Physics , vol.14 , Issue.4 , pp. 533-537
    • Cunningham, I.A.1    Fenster, A.2
  • 6
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge device
    • E. Samei, M. J. Flynn and D. A. Reimann, "A method for measuring the presampled MTF of digital radiographic systems using an edge device", Medical Physics 25(1), pp.102-113, 1998.
    • (1998) Medical Physics , vol.25 , Issue.1 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 7
    • 0033795913 scopus 로고    scopus 로고
    • Evaluation of an algorithm for the assessment of the MTF using an edge method
    • P. B. Greer and T. van Doom, "Evaluation of an algorithm for the assessment of the MTF using an edge method", Medical Physics 27(9), pp.2048-2294, 1999.
    • (1999) Medical Physics , vol.27 , Issue.9 , pp. 2048-2294
    • Greer, P.B.1    Van Doom, T.2
  • 8
    • 0141520703 scopus 로고    scopus 로고
    • Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image
    • E. Buhr, S. Gunther-Kohfahl and U. Neitzel, "Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image", Medical Physics 30(9), pp.2323-2331, 2003.
    • (2003) Medical Physics , vol.30 , Issue.9 , pp. 2323-2331
    • Buhr, E.1    Gunther-Kohfahl, S.2    Neitzel, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.