메뉴 건너뛰기




Volumn 21, Issue 6, 2004, Pages 926-936

Comparison of real and computer-simulated outcomes of LASIK refractive surgery

Author keywords

[No Author keywords available]

Indexed keywords

ABERRATIONS; ALGORITHMS; ASPHERICS; COMPUTATIONAL METHODS; COMPUTER SIMULATION; LASER ABLATION; LASER PULSES; LEAST SQUARES APPROXIMATIONS; LIGHT REFLECTION; MATHEMATICAL MODELS; REFRACTIVE INDEX; WAVEFRONTS;

EID: 3042524985     PISSN: 10847529     EISSN: None     Source Type: Journal    
DOI: 10.1364/JOSAA.21.000926     Document Type: Article
Times cited : (65)

References (33)
  • 2
    • 0031866166 scopus 로고    scopus 로고
    • Laser in situ keratomileusis: Literature review of a developing technique
    • S. Farah, D. Azar, C. Gurdal, and J. Wong, "Laser in situ keratomileusis: literature review of a developing technique," J. Cataract Refract. Surg. 24, 989-1006 (1998).
    • (1998) J. Cataract Refract. Surg. , vol.24 , pp. 989-1006
    • Farah, S.1    Azar, D.2    Gurdal, C.3    Wong, J.4
  • 3
    • 0036189248 scopus 로고    scopus 로고
    • Spot size and quality of scanning laser correction of higher-order wavefront aberrations
    • D. Huang and M. Arif, "Spot size and quality of scanning laser correction of higher-order wavefront aberrations," J. Cataract Refract. Surg. 28, 407-416 (2002).
    • (2002) J. Cataract Refract. Surg. , vol.28 , pp. 407-416
    • Huang, D.1    Arif, M.2
  • 4
    • 0035651024 scopus 로고    scopus 로고
    • Optical response to LASIK for myopia from total and corneal aberration measurements
    • S. Marcos, B. Barbero, L. Llorente, and J. Merayo-Lloves, "Optical response to LASIK for myopia from total and corneal aberration measurements," Invest. Ophthalmol. Visual Sci. 42, 3349-3356 (2001).
    • (2001) Invest. Ophthalmol. Visual Sci. , vol.42 , pp. 3349-3356
    • Marcos, S.1    Barbero, B.2    Llorente, L.3    Merayo-Lloves, J.4
  • 5
    • 0035031620 scopus 로고    scopus 로고
    • Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing
    • E. Moreno-Barriuso, J. Merayo-Lloves, S. Marcos, R. Navarro, L. Llorente, and S. Barbero, "Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing," Invest. Ophthalmol. Visual Sci. 42, 1396-1403 (2001).
    • (2001) Invest. Ophthalmol. Visual Sci. , vol.42 , pp. 1396-1403
    • Moreno-Barriuso, E.1    Merayo-Lloves, J.2    Marcos, S.3    Navarro, R.4    Llorente, L.5    Barbero, S.6
  • 6
    • 0035086297 scopus 로고    scopus 로고
    • Posterior corneal curvature changes after myopic laser in situ keratomileusis
    • B. Seitz, F. Torres, A. Langenbucher, A. Behrens, and E. S. Suarez, "Posterior corneal curvature changes after myopic laser in situ keratomileusis," Ophthalmology 108, 666-672 (2001).
    • (2001) Ophthalmology , vol.108 , pp. 666-672
    • Seitz, B.1    Torres, F.2    Langenbucher, A.3    Behrens, A.4    Suarez, E.S.5
  • 8
    • 0032903958 scopus 로고    scopus 로고
    • Functional vision and corneal changes after laser in situ keratomileusis determined by contrast sensitivity, glare testing and corneal topography
    • J. T. Holladay, D. R. Dudeja, and J. Chang, "Functional vision and corneal changes after laser in situ keratomileusis determined by contrast sensitivity, glare testing and corneal topography," J. Cataract Refract. Surg. 25, 663-669 (1999).
    • (1999) J. Cataract Refract. Surg. , vol.25 , pp. 663-669
    • Holladay, J.T.1    Dudeja, D.R.2    Chang, J.3
  • 9
    • 0032819591 scopus 로고    scopus 로고
    • Excimer ablation design and elliptical transition zones
    • S. MacRae, "Excimer ablation design and elliptical transition zones," J. Cataract Refract. Surg. 25, 1191-1197 (1999).
    • (1999) J. Cataract Refract. Surg. , vol.25 , pp. 1191-1197
    • MacRae, S.1
  • 10
    • 0001908929 scopus 로고    scopus 로고
    • Optical aberrations and ablation pattern design
    • S. McRae, R. Krueger, and R. Applegate, eds. (Slack, Inc. Thorofare, N.J.)
    • J. Schwiegerling, R. Snyder, and S. MacRae, "Optical aberrations and ablation pattern design," in Customized Corneal Ablation: The Quest for Super Vision, S. McRae, R. Krueger, and R. Applegate, eds. (Slack, Inc. Thorofare, N.J., 2001), pp. 96-107.
    • (2001) Customized Corneal Ablation: The Quest for Super Vision , pp. 96-107
    • Schwiegerling, J.1    Snyder, R.2    MacRae, S.3
  • 11
    • 0023858078 scopus 로고
    • Photorefractive keratectomy: A technique for laser refractive surgery
    • C. Munnerlyn, S. Koons, and J. Marshall, "Photorefractive keratectomy: a technique for laser refractive surgery," J. Cataract Refract. Surg. 14, 46-52 (1988).
    • (1988) J. Cataract Refract. Surg. , vol.14 , pp. 46-52
    • Munnerlyn, C.1    Koons, S.2    Marshall, J.3
  • 12
    • 0000370586 scopus 로고
    • Critical review on refractive surgical lasers
    • J. Lin, "Critical review on refractive surgical lasers," Opt. Eng. 34, 668-675 (1995).
    • (1995) Opt. Eng. , vol.34 , pp. 668-675
    • Lin, J.1
  • 13
    • 0037245277 scopus 로고    scopus 로고
    • Equation-for corneal asphericity after corneal refractive surgery
    • J. Jiménez, R. Anera, and L. Jiménez del Barco, "Equation-for corneal asphericity after corneal refractive surgery," J. Refract. Surg. 29, 65-69 (2003).
    • (2003) J. Refract. Surg. , vol.29 , pp. 65-69
    • Jiménez, J.1    Anera, R.2    Jiménez del Barco, L.3
  • 14
    • 0034947353 scopus 로고    scopus 로고
    • Determination of corneal asphericity after myopia surgery with the excimer laser: A mathematical model
    • D. Gatinel, T. Hoang-Xuan, and D. Azar, "Determination of corneal asphericity after myopia surgery with the excimer laser: a mathematical model," Invest. Ophthalmol. Visual Sci. 42, 1736-1742 (2001).
    • (2001) Invest. Ophthalmol. Visual Sci. , vol.42 , pp. 1736-1742
    • Gatinel, D.1    Hoang-Xuan, T.2    Azar, D.3
  • 15
    • 0036233743 scopus 로고    scopus 로고
    • Ablation profiles for wavefront-guided correction of myopia and primary spherical aberration
    • F. Manns, A. Ho, J. Parel, and W. Culbertson, "Ablation profiles for wavefront-guided correction of myopia and primary spherical aberration," J. Cataract Refract. Surg. 28, 766-774 (2002).
    • (2002) J. Cataract Refract. Surg. , vol.28 , pp. 766-774
    • Manns, F.1    Ho, A.2    Parel, J.3    Culbertson, W.4
  • 16
    • 0032159182 scopus 로고    scopus 로고
    • Custom photorefractive keratectomy ablations for the correction of spherical and cylindrical refractive error and higher-order aberration
    • J. Schwiegerling and R. Snyder, "Custom photorefractive keratectomy ablations for the correction of spherical and cylindrical refractive error and higher-order aberration," J. Opt. Soc. Am. A 15, 2572-2579 (1998).
    • (1998) J. Opt. Soc. Am. A , vol.15 , pp. 2572-2579
    • Schwiegerling, J.1    Snyder, R.2
  • 17
    • 79955998691 scopus 로고    scopus 로고
    • Effect on laser-ablation algorithms of reflection losses and nonnormal incidence on the anterior cornea
    • J. R. Jiménez, R. Anera, L. Jiménez del Barco, and E. Hita, "Effect on laser-ablation algorithms of reflection losses and nonnormal incidence on the anterior cornea," Appl. Phys. Lett. 81, 1521-1523 (2002).
    • (2002) Appl. Phys. Lett. , vol.81 , pp. 1521-1523
    • Jiménez, J.R.1    Anera, R.2    Jiménez del Barco, L.3    Hita, E.4
  • 18
    • 0035051523 scopus 로고    scopus 로고
    • Comparing laser ray tracing, spatially resolved refractometer and Hartmann-Shack sensor to measure the ocular wavefront aberration
    • E. Moreno-Barriuso, S. Marcos, R. Navarro, and S. A. Burns, "Comparing laser ray tracing, spatially resolved refractometer and Hartmann-Shack sensor to measure the ocular wavefront aberration," Optom. Vision Sci. 78, 152-156 (2001).
    • (2001) Optom. Vision Sci. , vol.78 , pp. 152-156
    • Moreno-Barriuso, E.1    Marcos, S.2    Navarro, R.3    Burns, S.A.4
  • 19
    • 0032606749 scopus 로고    scopus 로고
    • Laser ray-tracing method for optical testing
    • R. Navarro and E. Moreno-Barriuso, "Laser ray-tracing method for optical testing," Opt. Lett. 24, 1-3 (1999).
    • (1999) Opt. Lett. , vol.24 , pp. 1-3
    • Navarro, R.1    Moreno-Barriuso, E.2
  • 20
    • 0003145773 scopus 로고    scopus 로고
    • Standards for reporting the optical aberrations of eyes
    • Vol. 35 of OSA Trends in Optics and Photonics Series (Optical Society of America, Washington, D.C.)
    • L. N. Thibos, R. A. Applegate, J. T. Schwiegerling, R. H. Webb, and V. S. T. Members, "Standards for reporting the optical aberrations of eyes," in Vision Science and Its Applications, Vol. 35 of OSA Trends in Optics and Photonics Series (Optical Society of America, Washington, D.C., 2000), pp.110-130.
    • (2000) Vision Science and Its Applications , pp. 110-130
    • Thibos, L.N.1    Applegate, R.A.2    Schwiegerling, J.T.3    Webb, R.H.4    Members, V.S.T.5
  • 21
    • 0036735815 scopus 로고    scopus 로고
    • Total and corneal aberrations in an unilateral aphakic subject
    • S. Barbero, S. Marcos, and J. M. Merayo-Lloves, "Total and corneal aberrations in an unilateral aphakic subject," J. Cataract Refract. Surg. 28, 1594-1600 (2002).
    • (2002) J. Cataract Refract. Surg. , vol.28 , pp. 1594-1600
    • Barbero, S.1    Marcos, S.2    Merayo-Lloves, J.M.3
  • 22
    • 0036001139 scopus 로고    scopus 로고
    • Validation of the estimation of corneal aberrations from videokeratography in keratoconus
    • S. Barbero, S. Marcos, J. Merayo-Lloves, and E. Moreno-Barriuso, "Validation of the estimation of corneal aberrations from videokeratography in keratoconus," J. Refract. Surg. 18, 263-270 (2002).
    • (2002) J. Refract. Surg. , vol.18 , pp. 263-270
    • Barbero, S.1    Marcos, S.2    Merayo-Lloves, J.3    Moreno-Barriuso, E.4
  • 23
    • 84894020693 scopus 로고    scopus 로고
    • Understanding the standard algorithm for corneal refractive surgery using laser ablation of PMMA surfaces
    • C. Dorronsoro, D. Cano, S. Barbero, J. Merayo, L. Llorente, and S. Marcos, "Understanding the standard algorithm for corneal refractive surgery using laser ablation of PMMA surfaces," ARVO E-abstract 2535 (2003).
    • (2003) ARVO E-abstract 2535
    • Dorronsoro, C.1    Cano, D.2    Barbero, S.3    Merayo, J.4    Llorente, L.5    Marcos, S.6
  • 24
    • 0034832790 scopus 로고    scopus 로고
    • Influence of corneal curvature on calculation of ablation patterns used in photorefractive laser surgery
    • M. Mrochen and T. Seiler, "Influence of corneal curvature on calculation of ablation patterns used in photorefractive laser surgery," J. Refract. Surg. (Suppl.) 17, S584-S587 (2001).
    • (2001) J. Refract. Surg. , vol.17 , Issue.SUPPL.
    • Mrochen, M.1    Seiler, T.2
  • 26
    • 0034981461 scopus 로고    scopus 로고
    • Stress wave amplitudes during laser surgery of the cornea
    • R. Krueger, T. Seiler, T. Gruchman, M. Mrochen, and M. Berlin, "Stress wave amplitudes during laser surgery of the cornea," Opthalmology 108, 1070-1074 (2001).
    • (2001) Opthalmology , vol.108 , pp. 1070-1074
    • Krueger, R.1    Seiler, T.2    Gruchman, T.3    Mrochen, M.4    Berlin, M.5
  • 27
    • 0024213948 scopus 로고
    • Mass spectroscopic analysis of excimer laser ablated material from human corneal tissue
    • O. Kermani, H. Koort, E. Roth, and M. Dardenne, "Mass spectroscopic analysis of excimer laser ablated material from human corneal tissue," J. Cataract Refract. Surg. 14, 638-641 (1988).
    • (1988) J. Cataract Refract. Surg. , vol.14 , pp. 638-641
    • Kermani, O.1    Koort, H.2    Roth, E.3    Dardenne, M.4
  • 29
    • 0022801644 scopus 로고
    • Ablation of polymers and biological tissue by ultraviolet lasers
    • R. Srinivasan, "Ablation of polymers and biological tissue by ultraviolet lasers," Science 234, 559-565 (1986).
    • (1986) Science , vol.234 , pp. 559-565
    • Srinivasan, R.1
  • 30
    • 0029160918 scopus 로고
    • Excimer laser photorefractive keratectomy
    • T. Seiler and P. McDonnell, "Excimer laser photorefractive keratectomy," Surv. Ophthalmol. 40, 89-118 (1995).
    • (1995) Surv. Ophthalmol. , vol.40 , pp. 89-118
    • Seiler, T.1    McDonnell, P.2
  • 31
    • 0000057608 scopus 로고    scopus 로고
    • Corneal-tissue absorption coefficients for 193- and 213-nm ultraviolet radiation
    • G. Pettit and M. Ediger, "Corneal-tissue absorption coefficients for 193- and 213-nm ultraviolet radiation," Appl. Opt. 35, 3386-3391 (1996).
    • (1996) Appl. Opt. , vol.35 , pp. 3386-3391
    • Pettit, G.1    Ediger, M.2
  • 32
    • 0027954062 scopus 로고
    • Excimer laser ablation rate and corneal hydration
    • P. Dougherty, K. Wellish, and R. Maloney, "Excimer laser ablation rate and corneal hydration," Am. J. Ophthalmol. 118, 169-176 (1994).
    • (1994) Am. J. Ophthalmol. , vol.118 , pp. 169-176
    • Dougherty, P.1    Wellish, K.2    Maloney, R.3
  • 33
    • 0037374609 scopus 로고    scopus 로고
    • Mathematical model of corneal surface smoothing after laser refractive surgery
    • D. Huang, T. Maolong, and R. Shekhar, "Mathematical model of corneal surface smoothing after laser refractive surgery," Am. J. Ophthalmol. 135, 267-278 (2003).
    • (2003) Am. J. Ophthalmol. , vol.135 , pp. 267-278
    • Huang, D.1    Maolong, T.2    Shekhar, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.