Volumn 40, Issue 1, 2006, Pages 281-288

Statistical procedures for determination and verification of minimum reporting levels for drinking water methods

Author keywords

[No Author keywords available]

Indexed keywords

DATA ACQUISITION; GROUNDWATER; LEAST SQUARES APPROXIMATIONS; REGRESSION ANALYSIS; SAMPLING; STATISTICAL METHODS;

EID: 30344445663     PISSN: 0013936X     EISSN: None     Source Type: Journal    
DOI: 10.1021/es051069f     Document Type: Article
Times cited : (41)

References (25)
  • 1
    • 0033039021 scopus 로고    scopus 로고
    • Detection and quantification limits: Origins and historical overview
    • Currie, L. A. Detection and quantification limits: origins and historical overview. Anal. Chim. Acta 1999, 391, 105-126.
    • (1999) Anal. Chim. Acta , vol.391 , pp. 105-126
    • Currie, L.A.1
  • 2
    • 23544462582 scopus 로고
    • Limits for qualitative detection and quantitative determination
    • Currie, L. A. Limits for qualitative detection and quantitative determination. Anal. Chem. 1968, 40, 586-593.
    • (1968) Anal. Chem. , vol.40 , pp. 586-593
    • Currie, L.A.1
  • 8
    • 0031194101 scopus 로고    scopus 로고
    • An alternative minimum level definition for analytical quantification
    • Gibbons, R. D.; Coleman, D.E.; Maddalone, R. F. An alternative minimum level definition for analytical quantification. Environ. Sci. Technol. 1997, 31, 2071-2077.
    • (1997) Environ. Sci. Technol. , vol.31 , pp. 2071-2077
    • Gibbons, R.D.1    Coleman, D.E.2    Maddalone, R.F.3
  • 10
    • 33947294986 scopus 로고
    • Decision and detection limits for linear calibration curves
    • Hubaux, A.; Vos, G. Decision and detection limits for linear calibration curves. Anal. Chem. 1970, 42, 8 849-855.
    • (1970) Anal. Chem. , vol.42 , pp. 8849-8855
    • Hubaux, A.1    Vos, G.2
  • 11
    • 30344467947 scopus 로고    scopus 로고
    • A pragmatic approach for determining quantitation levels for regulatory purposes
    • American Water Works Association: Denver, CO
    • Sanders, P. F.; Lippincott, R. L.; Eaton, A. A Pragmatic Approach for Determining Quantitation Levels for Regulatory Purposes. Proceedings of the Water Quality Technology Conference; American Water Works Association: Denver, CO, 1996; Vol. 2.
    • (1996) Proceedings of the Water Quality Technology Conference , vol.2
    • Sanders, P.F.1    Lippincott, R.L.2    Eaton, A.3
  • 12
    • 0024654130 scopus 로고
    • Determination of practical quantitation levels for organic compounds in drinking water
    • Oxenford, J. L.; McGeorge, L. J.; Jennis, S. W. Determination of Practical Quantitation Levels for Organic Compounds in Drinking Water. J.-Am. Water Works Assoc. 1989, 149-153.
    • (1989) J.-Am. Water Works Assoc. , pp. 149-153
    • Oxenford, J.L.1    McGeorge, L.J.2    Jennis, S.W.3
  • 13
    • 4944236961 scopus 로고
    • Minimum reporting levels based on precision and accuracy for inorganic parameters in water
    • American Water Works Association: Denver, CO
    • Hertz, C. D.; Bordovsky, J.; Marrollo, L.; Harper, R. E. Minimum Reporting Levels Based on Precision and Accuracy for inorganic parameters in water. Proceedings of the Water Quality Technology Conference, American Water Works Association: Denver, CO, 1992.
    • (1992) Proceedings of the Water Quality Technology Conference
    • Hertz, C.D.1    Bordovsky, J.2    Marrollo, L.3    Harper, R.E.4
  • 14
    • 0028181996 scopus 로고
    • Quality control level: An alternative to detection levels
    • Kimbrough, D. E.; Wakakuwa, J. Quality control level: an alternative to detection levels. Environ. Sci. Technol. 1994, 28, 338-345.
    • (1994) Environ. Sci. Technol. , vol.28 , pp. 338-345
    • Kimbrough, D.E.1    Wakakuwa, J.2
  • 15
    • 0013247086 scopus 로고
    • Statistical treatment for rejection of deviant values: Critical values of Dixon's "Q" parameter and related subrange ratios at the 95% confidence level
    • Rorabacher, D. B. Statistical Treatment for Rejection of Deviant Values: Critical Values of Dixon's "Q" Parameter and Related Subrange Ratios at the 95% Confidence Level. Anal. Chem. 1991, 63, 139-146.
    • (1991) Anal. Chem. , vol.63 , pp. 139-146
    • Rorabacher, D.B.1