메뉴 건너뛰기




Volumn 52, Issue 1, 2006, Pages 152-153

Effect of addition of hemolysate on urine and cerebrospinal fluid assays for protein [1]

Author keywords

[No Author keywords available]

Indexed keywords

HEMOGLOBIN;

EID: 29744442085     PISSN: 00099147     EISSN: None     Source Type: Journal    
DOI: 10.1373/clinchem.2005.057547     Document Type: Letter
Times cited : (11)

References (8)
  • 1
    • 29744436154 scopus 로고    scopus 로고
    • Hemorrhagic cerebrovascular disease
    • Goldman L, Bennett JC, eds. Philadelphia: WB Saunders
    • Pulsinelli WA. Hemorrhagic cerebrovascular disease. In: Goldman L, Bennett JC, eds. Cecil textbook of medicine. Philadelphia: WB Saunders, 2000:2109-16.
    • (2000) Cecil Textbook of Medicine , pp. 2109-2116
    • Pulsinelli, W.A.1
  • 2
    • 85007902950 scopus 로고
    • Color reaction between pyrogallol red-molybdenum (VI) complex and protein
    • Fujita Y, Mori I, Kitano S. Color reaction between pyrogallol red-molybdenum (VI) complex and protein. Bunseki Kagaku 1983;32:E379-86.
    • (1983) Bunseki Kagaku , vol.32
    • Fujita, Y.1    Mori, I.2    Kitano, S.3
  • 3
    • 0018610784 scopus 로고
    • New micro-turbidimetric method for determination of protein in cerebrospinal fluid and urine
    • Iwata J, Nishikaze O. New micro-turbidimetric method for determination of protein in cerebrospinal fluid and urine. Clin Chem 1979;25:1317-9.
    • (1979) Clin Chem , vol.25 , pp. 1317-1319
    • Iwata, J.1    Nishikaze, O.2
  • 4
    • 3242759889 scopus 로고    scopus 로고
    • Automated turbidimetric benzalkonium chloride method for measurement of protein in urine and cerebrospinal fluid
    • Yiilmaz FM, Çelebi N, Yücel D. Automated turbidimetric benzalkonium chloride method for measurement of protein in urine and cerebrospinal fluid. Clin Chem 2004;50:1450-2.
    • (2004) Clin Chem , vol.50 , pp. 1450-1452
    • Yiilmaz, F.M.1    Çelebi, N.2    Yücel, D.3
  • 5
    • 0027171503 scopus 로고
    • Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays
    • Jay DW, Provasek D. Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays. Clin Chem 1993;39:1804-10.
    • (1993) Clin Chem , vol.39 , pp. 1804-1810
    • Jay, D.W.1    Provasek, D.2
  • 6
    • 0023758475 scopus 로고
    • Effects of sodium dodecylsulphate, dye concentration and paraprotein on Coomassie Blue dye binding assays for protein in urine
    • Lim CW, Chisnall WN, Stokes YM, Pratt R, Crooke MJ. Effects of sodium dodecylsulphate, dye concentration and paraprotein on Coomassie Blue dye binding assays for protein in urine. Clin Biochem 1988;21:277-81.
    • (1988) Clin Biochem , vol.21 , pp. 277-281
    • Lim, C.W.1    Chisnall, W.N.2    Stokes, Y.M.3    Pratt, R.4    Crooke, M.J.5
  • 7
    • 0029775048 scopus 로고    scopus 로고
    • Evaluation of an automated pyrogallol red-molybdate method for the measurement of urinary protein in rats
    • Lynch KM, Sellers TS, Gossett KA. Evaluation of an automated pyrogallol red-molybdate method for the measurement of urinary protein in rats. Eur J Clin Chem Clin Biochem 1996;34:569-71.
    • (1996) Eur J Clin Chem Clin Biochem , vol.34 , pp. 569-571
    • Lynch, K.M.1    Sellers, T.S.2    Gossett, K.A.3
  • 8
    • 0008846050 scopus 로고
    • Chemical and diagnostic specificity of laboratory tests
    • Caraway WT. Chemical and diagnostic specificity of laboratory tests. Am J Clin Pathol 1962;37:445-64.
    • (1962) Am J Clin Pathol , vol.37 , pp. 445-464
    • Caraway, W.T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.