메뉴 건너뛰기




Volumn 20, Issue 1, 2006, Pages 35-41

Vascular closure stapler clip anastomosis decreases aortic cross-clamping time compared to interrupted nonabsorbable and running absorbable sutures in growing pigs

Author keywords

[No Author keywords available]

Indexed keywords

ABSORBABLE SUTURE; POLYGLYCOLIC ACID; POLYPROPYLENE;

EID: 29744437093     PISSN: 08905096     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10016-005-9321-z     Document Type: Article
Times cited : (10)

References (34)
  • 2
    • 0022457599 scopus 로고
    • The use of synthetic absorbable suture materials (polyglycolid and polydioxanone) in the low pressure circulatory system of growing organims
    • Töns CH, Armbrecht J, Bircks W. The use of synthetic absorbable suture materials (polyglycolid and polydioxanone) in the low pressure circulatory system of growing organims. Thorac Cardiovasc Surg 1986;34:128-131.
    • (1986) Thorac Cardiovasc Surg , vol.34 , pp. 128-131
    • Töns, C.H.1    Armbrecht, J.2    Bircks, W.3
  • 4
    • 0346998277 scopus 로고    scopus 로고
    • Clips metálicos VCS, una novedosa técnica de sutura que permite el crecimiento longitudinal y transversal de los vasos: Avance preliminar
    • Calles-Vázquez MC, Lima MA, Viguera FJ, Usón JM, Usón J. Clips metálicos VCS, una novedosa técnica de sutura que permite el crecimiento longitudinal y transversal de los vasos: avance preliminar. Patol Vasc 2001;7:535-542.
    • (2001) Patol Vasc , vol.7 , pp. 535-542
    • Calles-Vázquez, M.C.1    Lima, M.A.2    Viguera, F.J.3    Usón, J.M.4    Usón, J.5
  • 5
    • 0036314051 scopus 로고    scopus 로고
    • End-to-end anastomosis in growing vessels using a novel suturing technique: VCS metallic staples
    • Calles MC, Lima MA, Crisóstomo V, Usón JM, Usón J. End-to-end anastomosis in growing vessels using a novel suturing technique: VCS metallic staples. Ann Vasc Surg 2002;16:345-352.
    • (2002) Ann Vasc Surg , vol.16 , pp. 345-352
    • Calles, M.C.1    Lima, M.A.2    Crisóstomo, V.3    Usón, J.M.4    Usón, J.5
  • 7
    • 0036517911 scopus 로고    scopus 로고
    • Ultrasonographic experimental study on the evolution of vascular anastomosis with metallic clips in growing sheep carotid artery
    • Lima MA, Calles MC, Lima JR, et al. Ultrasonographic experimental study on the evolution of vascular anastomosis with metallic clips in growing sheep carotid artery. Vet Radiol Ultrasound 2002;43:171-177.
    • (2002) Vet Radiol Ultrasound , vol.43 , pp. 171-177
    • Lima, M.A.1    Calles, M.C.2    Lima, J.R.3
  • 8
    • 0346500862 scopus 로고    scopus 로고
    • Clips metálicos VCS: Una técnica de sutura más rápida y fácil de utilizar que la sutura convencional en reconstrucciones de vasos en crecimiento
    • Calles Vázquez MC, Usón Casaús JM, Lima Rodríguez MA, Viguera Salvago FJ, Usón Gargallo J. Clips metálicos VCS: una técnica de sutura más rápida y fácil de utilizar que la sutura convencional en reconstrucciones de vasos en crecimiento. Angiologia 2003;55:497-509.
    • (2003) Angiologia , vol.55 , pp. 497-509
    • Calles Vázquez, M.C.1    Usón Casaús, J.M.2    Lima Rodríguez, M.A.3    Viguera Salvago, F.J.4    Usón Gargallo, J.5
  • 9
    • 0032101022 scopus 로고    scopus 로고
    • Rapid arterial anastomosis with titanium clips
    • Pikoulis E, Burris D, Rhee P, et al. Rapid arterial anastomosis with titanium clips. Am J Surg 1998;175:494-496.
    • (1998) Am J Surg , vol.175 , pp. 494-496
    • Pikoulis, E.1    Burris, D.2    Rhee, P.3
  • 10
    • 0032817196 scopus 로고    scopus 로고
    • Preliminary prospective randomized experience with vascular clips in the creation of arteriovenous fistulae for hemodialysis
    • Schild AF, Raines J. Preliminary prospective randomized experience with vascular clips in the creation of arteriovenous fistulae for hemodialysis. Am J Surg 1999;178:33-37.
    • (1999) Am J Surg , vol.178 , pp. 33-37
    • Schild, A.F.1    Raines, J.2
  • 11
    • 0034103790 scopus 로고    scopus 로고
    • Experimental lung transplantation using non-penetrating vascular clips for anastomosis of the pulmonary artery
    • Watanabe M, Yu SK, Sawafuji M, et al. Experimental lung transplantation using non-penetrating vascular clips for anastomosis of the pulmonary artery. Thorac Cardiovasc Surg 2000;48:120-122.
    • (2000) Thorac Cardiovasc Surg , vol.48 , pp. 120-122
    • Watanabe, M.1    Yu, S.K.2    Sawafuji, M.3
  • 14
    • 0030834268 scopus 로고    scopus 로고
    • Nonpenetrating clips for coronary anastomosis
    • Nataf P, Kirsch W, Hill AC, et al. Nonpenetrating clips for coronary anastomosis. Ann Thorac Surg 1997;63:S135-S137.
    • (1997) Ann Thorac Surg , vol.63
    • Nataf, P.1    Kirsch, W.2    Hill, A.C.3
  • 15
    • 0035318803 scopus 로고    scopus 로고
    • A comparison of para-anastomotic compliance profiles after vascular anastomosis: Nonpenetrating clips versus standard sutures
    • Baguneid MS, Goldner S, Fulford PE, Hamilton G, Walker MG, Seifalian AM. A comparison of para-anastomotic compliance profiles after vascular anastomosis: nonpenetrating clips versus standard sutures. J Vasc Surg 2001;33:812-820.
    • (2001) J Vasc Surg , vol.33 , pp. 812-820
    • Baguneid, M.S.1    Goldner, S.2    Fulford, P.E.3    Hamilton, G.4    Walker, M.G.5    Seifalian, A.M.6
  • 16
    • 0034234570 scopus 로고    scopus 로고
    • Vascular clips have no significant effect on the cellular proliferation, intimal changes, or peak systolic velocity at anastomoses in rabbit vein grafts
    • Caiati JM, Madigan JD, Bhagat G, Benvenisty AI, Nowygrod R, Todd GJ. Vascular clips have no significant effect on the cellular proliferation, intimal changes, or peak systolic velocity at anastomoses in rabbit vein grafts. J Surg Res 2000;92:29-35.
    • (2000) J Surg Res , vol.92 , pp. 29-35
    • Caiati, J.M.1    Madigan, J.D.2    Bhagat, G.3    Benvenisty, A.I.4    Nowygrod, R.5    Todd, G.J.6
  • 17
    • 0034538338 scopus 로고    scopus 로고
    • Comparison of titanium vascular closure staples with suture repair of the thoracic aorta in swine
    • Deb S, Martin B, Sun L, et al. Comparison of titanium vascular closure staples with suture repair of the thoracic aorta in swine. Chest 2000;118:1762-1768.
    • (2000) Chest , vol.118 , pp. 1762-1768
    • Deb, S.1    Martin, B.2    Sun, L.3
  • 18
    • 0035092397 scopus 로고    scopus 로고
    • Can minimal arterial aggressions using non-penetrating mechanical clip suture prevent myo-intimal hyperplasia? Preliminary results
    • Ducasse E, Basseau F, Puppinck P, Baquey C. Can minimal arterial aggressions using non-penetrating mechanical clip suture prevent myo-intimal hyperplasia? Preliminary results. J Mal Vasc 2001;26:50-54.
    • (2001) J Mal Vasc , vol.26 , pp. 50-54
    • Ducasse, E.1    Basseau, F.2    Puppinck, P.3    Baquey, C.4
  • 19
    • 0031916025 scopus 로고    scopus 로고
    • VCS microclip anastomosis on blood vessels of less than 2 millimeters in diameter. Preliminary experimental study in the rat
    • Gerbault O, Arrouvel C, Servant JM, Revol M, Banzet P. VCS microclip anastomosis on blood vessels of less than 2 millimeters in diameter. Preliminary experimental study in the rat. Ann Chir Plast Esthet 1998;43:27-39.
    • (1998) Ann Chir Plast Esthet , vol.43 , pp. 27-39
    • Gerbault, O.1    Arrouvel, C.2    Servant, J.M.3    Revol, M.4    Banzet, P.5
  • 20
    • 0033069344 scopus 로고    scopus 로고
    • The VCS clip - Experimental experiences with a new vascular suture stapling device
    • Berlin
    • Golling M, Mehrabi A, Weiss G, Schaffer F, Kraus T, Klar E. The VCS clip - experimental experiences with a new vascular suture stapling device. Chirurg (Berlin) 1999;70:206-210.
    • (1999) Chirurg , vol.70 , pp. 206-210
    • Golling, M.1    Mehrabi, A.2    Weiss, G.3    Schaffer, F.4    Kraus, T.5    Klar, E.6
  • 21
    • 0031917918 scopus 로고    scopus 로고
    • Vascular microanastomosis by eversion and stapling using VCS forceps. Presentation of the technique and experimental evaluation of its reliability
    • Lambert F, Couturaud B, Cruel T, Lecoin G, Cariou JL. Vascular microanastomosis by eversion and stapling using VCS forceps. Presentation of the technique and experimental evaluation of its reliability. Ann Chir Plast Esthet 1998;43:14-26.
    • (1998) Ann Chir Plast Esthet , vol.43 , pp. 14-26
    • Lambert, F.1    Couturaud, B.2    Cruel, T.3    Lecoin, G.4    Cariou, J.L.5
  • 22
    • 0035375781 scopus 로고    scopus 로고
    • Anastomosis of vessels less than 2 mm with the vascular clip system clip applier
    • Lee JW, Choo SJ, Oh JH, et al. Anastomosis of vessels less than 2 mm with the vascular clip system clip applier. J Korean Med Sci 2001;16:303-308.
    • (2001) J Korean Med Sci , vol.16 , pp. 303-308
    • Lee, J.W.1    Choo, S.J.2    Oh, J.H.3
  • 23
    • 0036312364 scopus 로고    scopus 로고
    • Primary sciatic nerve repair using titanium staples
    • Payne CE, Hunt SP, Lamberty BG. Primary sciatic nerve repair using titanium staples. Br J Plast Surg 2002;55:330-334.
    • (2002) Br J Plast Surg , vol.55 , pp. 330-334
    • Payne, C.E.1    Hunt, S.P.2    Lamberty, B.G.3
  • 24
    • 0034932978 scopus 로고    scopus 로고
    • Study comparing sutures and nonpenetrating titanium clips for arteriotomy closure after embolectomy
    • Pikoulis E, Koronarchis D, Filis K, et al. Study comparing sutures and nonpenetrating titanium clips for arteriotomy closure after embolectomy. Surg Endosc 2001; 15:726-728.
    • (2001) Surg Endosc , vol.15 , pp. 726-728
    • Pikoulis, E.1    Koronarchis, D.2    Filis, K.3
  • 25
    • 0032427234 scopus 로고    scopus 로고
    • Arterial reconstruction with vascular clips is safe and quicker than sutured repair
    • Pikoulis E, Rhee P, Nishibe T, et al. Arterial reconstruction with vascular clips is safe and quicker than sutured repair. Cardiovasc Surg 1998;6:573-578.
    • (1998) Cardiovasc Surg , vol.6 , pp. 573-578
    • Pikoulis, E.1    Rhee, P.2    Nishibe, T.3
  • 26
    • 0033996960 scopus 로고    scopus 로고
    • Arterial repair with synthetic patch by using titanium clips
    • Pikoulis E, Rhee P, Nishibe T, et al. Arterial repair with synthetic patch by using titanium clips. J Trauma 2000;48:292-295.
    • (2000) J Trauma , vol.48 , pp. 292-295
    • Pikoulis, E.1    Rhee, P.2    Nishibe, T.3
  • 27
    • 0022360133 scopus 로고
    • Comparison of suture and clip for microvascular anastomoses
    • Zhu YH, Kirsch WM, Cushman R, et al. Comparison of suture and clip for microvascular anastomoses. Surg Forum 1985;36:492-495.
    • (1985) Surg Forum , vol.36 , pp. 492-495
    • Zhu, Y.H.1    Kirsch, W.M.2    Cushman, R.3
  • 28
    • 0035669044 scopus 로고    scopus 로고
    • Preservation of endothelial integrity and function in experimental vascular anastomosis with non-penetrating clips
    • Zeebregts C, van den Dungen J, Buikema H, van der Want J, van Schilfgaarde R. Preservation of endothelial integrity and function in experimental vascular anastomosis with non-penetrating clips. Br J Surg 2001;88:1201-1208.
    • (2001) Br J Surg , vol.88 , pp. 1201-1208
    • Zeebregts, C.1    Van Den Dungen, J.2    Buikema, H.3    Van Der Want, J.4    Van Schilfgaarde, R.5
  • 29
    • 0031914898 scopus 로고    scopus 로고
    • A new anastomotic technique in renal transplants reduces warm ischemia time
    • Jones JW. A new anastomotic technique in renal transplants reduces warm ischemia time. Clin Transpl 1998;12:70-72.
    • (1998) Clin Transpl , vol.12 , pp. 70-72
    • Jones, J.W.1
  • 30
    • 0032842034 scopus 로고    scopus 로고
    • Anastomotic tissue response associated with expanded polytetrafluoroethylene access grafts constructed by using nonpenetrating clips
    • Dal Ponte DB, Berman SS, Patula VB, Kleinert LB, Williams SK. Anastomotic tissue response associated with expanded polytetrafluoroethylene access grafts constructed by using nonpenetrating clips. J Vasc Surg 1999;30:325-333.
    • (1999) J Vasc Surg , vol.30 , pp. 325-333
    • Dal Ponte, D.B.1    Berman, S.S.2    Patula, V.B.3    Kleinert, L.B.4    Williams, S.K.5
  • 31
    • 0032892935 scopus 로고    scopus 로고
    • Comparison of arcuate-legged clipped versus sutured hepatic artery, portal vein, and bile duct anastomoses
    • Geevarghese SK, Bradley AL, Atkinson J, et al. Comparison of arcuate-legged clipped versus sutured hepatic artery, portal vein, and bile duct anastomoses. Am Surg 1999;65:311-316.
    • (1999) Am Surg , vol.65 , pp. 311-316
    • Geevarghese, S.K.1    Bradley, A.L.2    Atkinson, J.3
  • 32
    • 77049191928 scopus 로고
    • Method of blood vessel anastomosis by means of metal clips
    • Samuels PB. Method of blood vessel anastomosis by means of metal clips. Arch Surg 1955;70:29-38.
    • (1955) Arch Surg , vol.70 , pp. 29-38
    • Samuels, P.B.1
  • 33
    • 0035092180 scopus 로고    scopus 로고
    • Patency and flow characteristics using stapled vascular anastomoses in dialysis grafts
    • Cook JW, Schuman ES, Standage BA, Heinl P. Patency and flow characteristics using stapled vascular anastomoses in dialysis grafts. Am J Surg 2001;18:24-27.
    • (2001) Am J Surg , vol.18 , pp. 24-27
    • Cook, J.W.1    Schuman, E.S.2    Standage, B.A.3    Heinl, P.4
  • 34


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.