메뉴 건너뛰기




Volumn 55, Issue 6, 2003, Pages 497-509

Metallic VCS clips: A suturing technique that is quicker and easier to use than conventional suture in the reconstruction of growing vessels;Clips metálicos VCS: Una técnica de sutura más rápida y fácil de utilizar que la sutura convencional en reconstrucciones de vasos en crecimiento

Author keywords

Anastomosis; Arteries; Growth; Metallic VCS clips; Polypropylene; Time; Veins

Indexed keywords

POLYPROPYLENE; SUTURE MATERIAL; TITANIUM;

EID: 0346500862     PISSN: 00033170     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0003-3170(03)74831-7     Document Type: Article
Times cited : (6)

References (49)
  • 1
    • 0019121030 scopus 로고
    • Methods of management and results following surgery for coarctation of the aorta in infancy
    • Allen RG, García M, Neyek G. Methods of management and results following surgery for coarctation of the aorta in infancy. J Pediatr Surg 1980; 15: 953-60.
    • (1980) J Pediatr Surg , vol.15 , pp. 953-960
    • Allen, R.G.1    García, M.2    Neyek, G.3
  • 4
    • 0022349334 scopus 로고
    • Early results after resection and end-to-end anastomosis of coarctation of thoracic aorta in early infancy
    • Körfer R, Meyer H, Kleikamp G, Birc Ks W. Early results after resection and end-to-end anastomosis of coarctation of thoracic aorta in early infancy. J Thorac Cardiovasc Surg 1985; 89: 616-22.
    • (1985) J Thorac Cardiovasc Surg , vol.89 , pp. 616-622
    • Körfer, R.1    Meyer, H.2    Kleikamp, G.3    Birc Ks, W.4
  • 5
    • 0017716138 scopus 로고
    • Coarctation of aorta with special reference to infants. Long-term results of operation in 126 cases
    • Patel R, Singh SP, Abrams L, Roberts KD. Coarctation of aorta with special reference to infants. Long-term results of operation in 126 cases. Br Heart J 1977; 39: 556-8.
    • (1977) Br Heart J , vol.39 , pp. 556-558
    • Patel, R.1    Singh, S.P.2    Abrams, L.3    Roberts, K.D.4
  • 8
    • 0022457599 scopus 로고
    • The use of synthetic absorbable suture materials (polyglycolid and polydioxanone in the low pressure circulatory system of growing organisms)
    • Tóns CH, Armbrecht J, Bircks W. The use of synthetic absorbable suture materials (polyglycolid and polydioxanone in the low pressure circulatory system of growing organisms). Thorac Cardiovasc Surg 1986; 34: 128-31.
    • (1986) Thorac Cardiovasc Surg , vol.34 , pp. 128-131
    • Tóns, C.H.1    Armbrecht, J.2    Bircks, W.3
  • 10
    • 0346998277 scopus 로고    scopus 로고
    • Clips Metálicos Vcs. una novedosa técnica de sutura que permite el crecimiento longitudinal y transversal de los vasos: Avance preliminar
    • Calles-Vázquez MC, Lima MA, Viguera FJ, Usón JM, Usón J. Clips metálicos VCS, una novedosa técnica de sutura que permite el crecimiento longitudinal y transversal de los vasos: avance preliminar. Patologia Vascular 2001; 7: 535-42.
    • (2001) Patologia Vascular , vol.7 , pp. 535-542
    • Calles-Vázquez, M.C.1    Lima, M.A.2    Viguera, F.J.3    Usón, J.M.4    Usón, J.5
  • 11
    • 0036314051 scopus 로고    scopus 로고
    • End-to-end anastomosis in growing vessels using a novel suturing technique: VCS metallic staples
    • Calles MC, Lima MA, Crisóstomo V, Usón JM, Usón J. End-to-end anastomosis in growing vessels using a novel suturing technique: VCS metallic staples. Ann Vasc Surg 2002; 16: 345-52.
    • (2002) Ann Vasc Surg , vol.16 , pp. 345-352
    • Calles, M.C.1    Lima, M.A.2    Crisóstomo, V.3    Usón, J.M.4    Usón, J.5
  • 12
    • 0036517911 scopus 로고    scopus 로고
    • Ultrasonographic experimental study on the evolution of vascular anastomosis with metallic clips in growing sheep carotid artery
    • Lima MA, Calles MC, Lima JR, Martin MF, Crisóstomo V, Hernández FJ, et al. Ultrasonographic experimental study on the evolution of vascular anastomosis with metallic clips in growing sheep carotid artery. Vet Radiol Ultrasound 2002; 43: 171-7.
    • (2002) Vet Radiol Ultrasound , vol.43 , pp. 171-177
    • Lima, M.A.1    Calles, M.C.2    Lima, J.R.3    Martin, M.F.4    Crisóstomo, V.5    Hernández, F.J.6
  • 14
    • 0032817196 scopus 로고    scopus 로고
    • Preliminary prospective randomized experience with vascular clips in the creation of arteriovenous fistulae for hemodialysis
    • Schild AF, Raines J. Preliminary prospective randomized experience with vascular clips in the creation of arteriovenous fistulae for hemodialysis. Am J Surg 1999; 178: 33-7.
    • (1999) Am J Surg , vol.178 , pp. 33-37
    • Schild, A.F.1    Raines, J.2
  • 15
    • 0034103790 scopus 로고    scopus 로고
    • Experimental lung transplantation using non-penetrating vascular clips for anastomosis of the pulmonary artery
    • Watanabe M, Yu SK, Sawafuji M, Kawamura M, Horinouchi H, Ikeda E, et al. Experimental lung transplantation using non-penetrating vascular clips for anastomosis of the pulmonary artery. Thorac Cardiov Surg 2000; 48: 120-2.
    • (2000) Thorac Cardiov Surg , vol.48 , pp. 120-122
    • Watanabe, M.1    Yu, S.K.2    Sawafuji, M.3    Kawamura, M.4    Horinouchi, H.5    Ikeda, E.6
  • 20
    • 20244389146 scopus 로고    scopus 로고
    • Can nonpenetrating vascular closure staples and hepatocyte growth factor prevent intimal hyperplasia following ePTFE grafting of the carotid artery in rabbits?
    • Akita M, Takenaka H, Harada M, Li TS, Zhang H, Zempo N, et al. Can nonpenetrating vascular closure staples and hepatocyte growth factor prevent intimal hyperplasia following ePTFE grafting of the carotid artery in rabbits? Surg Today 2002; 32: 618-22.
    • (2002) Surg Today , vol.32 , pp. 618-622
    • Akita, M.1    Takenaka, H.2    Harada, M.3    Li, T.S.4    Zhang, H.5    Zempo, N.6
  • 21
    • 0030738739 scopus 로고    scopus 로고
    • Scanning electron microscopic analysis of the stapled microvascular anastomosis in the rabbit
    • Boeckx WD, Darius O, Hof VD, Holder VC. Scanning electron microscopic analysis of the stapled microvascular anastomosis in the rabbit. Ann Thorac Surg 1997; 63: S128-34.
    • (1997) Ann Thorac Surg , vol.63
    • Boeckx, W.D.1    Darius, O.2    Hof, V.D.3    Holder, V.C.4
  • 22
    • 24544448795 scopus 로고    scopus 로고
    • Use of the VCS clip applier for microvascular anastomosis in free flap surgery
    • Cope C, Lee K, Stern H, Pennington D. Use of the VCS clip applier for microvascular anastomosis in free flap surgery. Plast Reconstr Surg 2000; 70 (Suppl): A122-3.
    • (2000) Plast Reconstr Surg , vol.70 , Issue.SUPPL.
    • Cope, C.1    Lee, K.2    Stern, H.3    Pennington, D.4
  • 24
    • 0031933249 scopus 로고    scopus 로고
    • Carotid arteriotomy closure using a vascular clip system
    • Findlay JM, Megyesi JF. Carotid arteriotomy closure using a vascular clip system. Neurosurgery 1998; 42: 550-4.
    • (1998) Neurosurgery , vol.42 , pp. 550-554
    • Findlay, J.M.1    Megyesi, J.F.2
  • 25
    • 0027085680 scopus 로고
    • A new method for microvascular anastomosis: Report of experimental and clinical research
    • Kirsch WM, Zhu YH, Hardesty R, Chapolini R. A new method for microvascular anastomosis: report of experimental and clinical research. Am Surg 1992; 58: 722-7.
    • (1992) Am Surg , vol.58 , pp. 722-727
    • Kirsch, W.M.1    Zhu, Y.H.2    Hardesty, R.3    Chapolini, R.4
  • 27
    • 0026766633 scopus 로고
    • Tissue reconstruction with nonpenetrating arcuate-legged clips (potential endoscopic applications)
    • Kirsch WM, Zhu YH, Gaskill D, Stewart S, Hardesty RA, Lyons TL. Tissue reconstruction with nonpenetrating arcuate-legged clips (potential endoscopic applications). J Reprod Med 1992; 37: 581-6.
    • (1992) J Reprod Med , vol.37 , pp. 581-586
    • Kirsch, W.M.1    Zhu, Y.H.2    Gaskill, D.3    Stewart, S.4    Hardesty, R.A.5    Lyons, T.L.6
  • 29
    • 0029842764 scopus 로고    scopus 로고
    • Sutures microchirurgicales par agrafes non transfixiantes. Étude expérimentale sur quinze aortes de rat
    • Rampillon F, Hailaud YM, Malka G, Justrabo E. Sutures microchirurgicales par agrafes non transfixiantes. Étude expérimentale sur quinze aortes de rat. Ann Chir Plast Esthet 1996; 41: 376-80.
    • (1996) Ann Chir Plast Esthet , vol.41 , pp. 376-380
    • Rampillon, F.1    Hailaud, Y.M.2    Malka, G.3    Justrabo, E.4
  • 30
    • 0035318803 scopus 로고    scopus 로고
    • A comparison of para-anastomotic compliance profiles after vascular anastomosis: Nonpenetrating clips versus standard sutures
    • Baguneid MS, Goldner S, Fulford PE, Hamilton G, Walker MG, Seifalian AM. A comparison of para-anastomotic compliance profiles after vascular anastomosis: nonpenetrating clips versus standard sutures. J Vasc Surg 2001; 33: 812-20.
    • (2001) J Vasc Surg , vol.33 , pp. 812-820
    • Baguneid, M.S.1    Goldner, S.2    Fulford, P.E.3    Hamilton, G.4    Walker, M.G.5    Seifalian, A.M.6
  • 31
    • 0034234570 scopus 로고    scopus 로고
    • Vascular clips have no significant effect on the cellular proliferation, intimal changes, or peak systolic velocity at anastomosis in rabbit vein grafts
    • Caiati JM, Madigan JD, Bhagat G, Benvenisty AI, Nowygrod R, Todd GJ. Vascular clips have no significant effect on the cellular proliferation, intimal changes, or peak systolic velocity at anastomosis in rabbit vein grafts. J Surg Res 2000; 92: 29-35.
    • (2000) J Surg Res , vol.92 , pp. 29-35
    • Caiati, J.M.1    Madigan, J.D.2    Bhagat, G.3    Benvenisty, A.I.4    Nowygrod, R.5    Todd, G.J.6
  • 32
    • 0034538338 scopus 로고    scopus 로고
    • Comparison of titanium vascular closure staples with suture repair of the thoracic aorta in swine
    • Deb S, Martin B, Sun L, Burris D, Wherry D, Pikoulis E, et al. Comparison of titanium vascular closure staples with suture repair of the thoracic aorta in swine. Chest 2000; 118: 1762-8.
    • (2000) Chest , vol.118 , pp. 1762-1768
    • Deb, S.1    Martin, B.2    Sun, L.3    Burris, D.4    Wherry, D.5    Pikoulis, E.6
  • 33
    • 0035092397 scopus 로고    scopus 로고
    • Can minimal arterial aggressions using nonpenetrating mechanical clip suture prevent myo-intimal hyperplasia? Preliminary results
    • Ducasse E, Basseau F, Puppinck P, Baquey C. Can minimal arterial aggressions using nonpenetrating mechanical clip suture prevent myo-intimal hyperplasia? Preliminary results. J Mal Vasc 2001; 26: 50-4.
    • (2001) J Mal Vasc , vol.26 , pp. 50-54
    • Ducasse, E.1    Basseau, F.2    Puppinck, P.3    Baquey, C.4
  • 34
    • 0031916025 scopus 로고    scopus 로고
    • VCS microclip anastomosis on blood vessels of less than 2 millimetres in diameter. Preliminary experimental study in the rat
    • Gerbault O, Arrouvel C, Servant JM, Revol M, Banzet P. VCS microclip anastomosis on blood vessels of less than 2 millimetres in diameter. Preliminary experimental study in the rat. Ann Chir Plast Esthet 1998; 43: 27-39.
    • (1998) Ann Chir Plast Esthet , vol.43 , pp. 27-39
    • Gerbault, O.1    Arrouvel, C.2    Servant, J.M.3    Revol, M.4    Banzet, P.5
  • 35
    • 0033069344 scopus 로고    scopus 로고
    • The VCS clip-experimental experiences with a new vascular suture stapling device
    • Golling M, Mehrabi A, Weiss G, Schaffer F, Kraus T, Klar E. The VCS clip-experimental experiences with a new vascular suture stapling device. Chirurg 1999; 70: 206-10.
    • (1999) Chirurg , vol.70 , pp. 206-210
    • Golling, M.1    Mehrabi, A.2    Weiss, G.3    Schaffer, F.4    Kraus, T.5    Klar, E.6
  • 36
    • 0031917918 scopus 로고    scopus 로고
    • Vascular microanastomosis by eversion and stapling using VCS forceps. Presentation of the technique and experimental evaluation of its reliability
    • Lambert F, Couturaud B, Cruel T, Lecoin G, Cariou JL. Vascular microanastomosis by eversion and stapling using VCS forceps. Presentation of the technique and experimental evaluation of its reliability. Ann Chir Plast Esthet 1998; 43: 14-26.
    • (1998) Ann Chir Plast Esthet , vol.43 , pp. 14-26
    • Lambert, F.1    Couturaud, B.2    Cruel, T.3    Lecoin, G.4    Cariou, J.L.5
  • 37
    • 0035375781 scopus 로고    scopus 로고
    • Anastomosis of vessels less than 2 mm with the vascular clip system clip applier
    • Lee JW, Choo SJ, Oh JH, Lee I, Kwon YM, Lee YJ, et al. Anastomosis of vessels less than 2 mm with the vascular clip system clip applier. J Korean Med Sci 2001; 16: 303-8.
    • (2001) J Korean Med Sci , vol.16 , pp. 303-308
    • Lee, J.W.1    Choo, S.J.2    Oh, J.H.3    Lee, I.4    Kwon, Y.M.5    Lee, Y.J.6
  • 38
    • 0036312364 scopus 로고    scopus 로고
    • Primary sciatic nerve repair using titanium staples
    • Payne CE, Hunt SP, Lamberty BC. Primary sciatic nerve repair using titanium staples. Br J Plast Surg 2002; 55: 330-4.
    • (2002) Br J Plast Surg , vol.55 , pp. 330-334
    • Payne, C.E.1    Hunt, S.P.2    Lamberty, B.C.3
  • 39
    • 0034932978 scopus 로고    scopus 로고
    • Study comparing sutures and nonpenetrating titanium clips for arteriotomy closure after embolectomy
    • Pikoulis E, Koronarchis D, Filis K, Leppaniemi A, Papas S, Xiromeritis N, et al. Study comparing sutures and nonpenetrating titanium clips for arteriotomy closure after embolectomy. Surg Endosc 2001; 15: 726-8.
    • (2001) Surg Endosc , vol.15 , pp. 726-728
    • Pikoulis, E.1    Koronarchis, D.2    Filis, K.3    Leppaniemi, A.4    Papas, S.5    Xiromeritis, N.6
  • 43
    • 0035669044 scopus 로고    scopus 로고
    • Preservation of endothelial integrity and function in experimental vascular anastomosis with nonpenetrating clips
    • Zeebregts C, Van den Dungen J, Buikema H, Van der Want J, Van Schilfgaarde R. Preservation of endothelial integrity and function in experimental vascular anastomosis with nonpenetrating clips. Br J Surg 2001; 88: 1201-8.
    • (2001) Br J Surg , vol.88 , pp. 1201-1208
    • Zeebregts, C.1    Van Den Dungen, J.2    Buikema, H.3    Van Der Want, J.4    Van Schilfgaarde, R.5
  • 44
    • 0031914898 scopus 로고    scopus 로고
    • A new anastomotic technique in renal transplants reduces warm ischemia time
    • Jones JW. A new anastomotic technique in renal transplants reduces warm ischemia time. Clin Transpl 1998; 12: 70-2.
    • (1998) Clin Transpl , vol.12 , pp. 70-72
    • Jones, J.W.1
  • 45
    • 0032842034 scopus 로고    scopus 로고
    • Anastomotic tissue response associated with expanded polytetrafluoroethylene access grafts constructed by using nonpenetrating clips
    • Dal Ponte DB, Berman SS, Patula VB, Kleinert LB, Williams SK. Anastomotic tissue response associated with expanded polytetrafluoroethylene access grafts constructed by using nonpenetrating clips. J Vasc Surg 1999; 30: 325-33.
    • (1999) J Vasc Surg , vol.30 , pp. 325-333
    • Dal Ponte, D.B.1    Berman, S.S.2    Patula, V.B.3    Kleinert, L.B.4    Williams, S.K.5
  • 46
    • 0032892935 scopus 로고    scopus 로고
    • Comparison of arcuate-legged clipped versus sutured hepatic artery, portal vein, and bile duct anastomoses
    • Geevarghese SK, Bradley AL, Atkinson J, Wright JK, Chapman WC, Van Buren DH, et al. Comparison of arcuate-legged clipped versus sutured hepatic artery, portal vein, and bile duct anastomoses. Am Surg 1999; 65: 311-6.
    • (1999) Am Surg , vol.65 , pp. 311-316
    • Geevarghese, S.K.1    Bradley, A.L.2    Atkinson, J.3    Wright, J.K.4    Chapman, W.C.5    Van Buren, D.H.6
  • 47
    • 77049191928 scopus 로고
    • Method of blood vessel anastomosis by means of metal clips
    • Samuels PB. Method of blood vessel anastomosis by means of metal clips. Arch Surg 1955; 70: 29-38.
    • (1955) Arch Surg , vol.70 , pp. 29-38
    • Samuels, P.B.1
  • 48
    • 0035092180 scopus 로고    scopus 로고
    • Patency and flow characteristics using stapled vascular anastomoses in dialysis grafts
    • Cook JW, Schuman ES, Standage BA, Heinl P. Patency and flow characteristics using stapled vascular anastomoses in dialysis grafts. Am J Surg 2001; 18: 24-7.
    • (2001) Am J Surg , vol.18 , pp. 24-27
    • Cook, J.W.1    Schuman, E.S.2    Standage, B.A.3    Heinl, P.4
  • 49


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.