메뉴 건너뛰기




Volumn 17, Issue 2, 2004, Pages 191-210

Optimized and wavefront guided corneal refractive surgery using the Carl Zeiss Meditec platform: The WASCA aberrometer, CRS-Master, and MEL80 excimer laser

Author keywords

[No Author keywords available]

Indexed keywords

BIOMECHANICS; CLINICAL PROTOCOL; CORNEA EPITHELIUM; CORNEA SURGERY; DEVICE; HUMAN; IN VIVO STUDY; KERATOMILEUSIS; LASER; PHOTOREFRACTIVE KERATECTOMY; PRIORITY JOURNAL; REFRACTIVE SURGERY; REPRODUCIBILITY; REVIEW; SURFACE PROPERTY; SURGEON; TECHNOLOGY; TREATMENT OUTCOME; TREATMENT PLANNING; VALIDATION PROCESS; WAVEFORM;

EID: 2942717061     PISSN: 08961549     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ohc.2004.03.005     Document Type: Review
Times cited : (20)

References (37)
  • 1
    • 0032922865 scopus 로고    scopus 로고
    • Comparison of corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis
    • Oshika T., Klyce S.D., Applegate R.A., Howland H.C., El Danasoury M.A. Comparison of corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis. Am J Ophthalmol. 127(1):1999;1-7
    • (1999) Am J Ophthalmol , vol.127 , Issue.1 , pp. 1-7
    • Oshika, T.1    Klyce, S.D.2    Applegate, R.A.3    Howland, H.C.4    El Danasoury, M.A.5
  • 2
    • 0003333241 scopus 로고    scopus 로고
    • Wavefront sensors for control and process monitoring in optics manufacture
    • Neal D.R., Armstrong D.J., Turner W.T. Wavefront sensors for control and process monitoring in optics manufacture. SPIE. 1997
    • (1997) SPIE
    • Neal, D.R.1    Armstrong, D.J.2    Turner, W.T.3
  • 3
    • 85077782675 scopus 로고    scopus 로고
    • Amplitude and phase beam characterization using a two-dimensional wavefront sensor
    • Neal D.R., Alford W.J., Gruetzner J.K. Amplitude and phase beam characterization using a two-dimensional wavefront sensor. SPIE. 1996;72-82
    • (1996) SPIE , pp. 72-82
    • Neal, D.R.1    Alford, W.J.2    Gruetzner, J.K.3
  • 6
    • 0037243289 scopus 로고    scopus 로고
    • Measurement of refractive errors in young myopes using the COAS Shack-Hartmann aberrometer
    • Salmon T.O., West R.W., Gasser W., Kenmore T. Measurement of refractive errors in young myopes using the COAS Shack-Hartmann aberrometer. Optom Vis Sci. 80(1):2003;6-14
    • (2003) Optom Vis Sci , vol.80 , Issue.1 , pp. 6-14
    • Salmon, T.O.1    West, R.W.2    Gasser, W.3    Kenmore, T.4
  • 7
    • 0014119291 scopus 로고
    • Keratomileusis
    • Barraquer J.I. Keratomileusis. Int Surg. 48(2):1967;103-117
    • (1967) Int Surg , vol.48 , Issue.2 , pp. 103-117
    • Barraquer, J.I.1
  • 8
    • 0023858078 scopus 로고
    • Photorefractive keratectomy: A technique for laser refractive surgery
    • Munnerlyn C.R., Koons S.J., Marshall J. Photorefractive keratectomy: a technique for laser refractive surgery. J Cataract Refract Surg. 14(1):1988;46-52
    • (1988) J Cataract Refract Surg , vol.14 , Issue.1 , pp. 46-52
    • Munnerlyn, C.R.1    Koons, S.J.2    Marshall, J.3
  • 10
    • 0028084929 scopus 로고
    • Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing
    • Reinstein D.Z., Silverman R.H., Rondeau M.J., Coleman D.J. Epithelial and corneal thickness measurements by high-frequency ultrasound digital signal processing. Ophthalmology. 101(1):1994;140-146
    • (1994) Ophthalmology , vol.101 , Issue.1 , pp. 140-146
    • Reinstein, D.Z.1    Silverman, R.H.2    Rondeau, M.J.3    Coleman, D.J.4
  • 11
    • 0034570104 scopus 로고    scopus 로고
    • [Correction of irregular astigmatism using excimer laser MEL 70 G-Scan with the TOSCA program-introductory report]
    • Wygledowska-Promienska D., Zawojska I., Gierek-Ciaciura S., Sarzynski A. [Correction of irregular astigmatism using excimer laser MEL 70 G-Scan with the TOSCA program-introductory report]. Klin Oczna. 102(6):2000;443-447
    • (2000) Klin Oczna , vol.102 , Issue.6 , pp. 443-447
    • Wygledowska-Promienska, D.1    Zawojska, I.2    Gierek-Ciaciura, S.3    Sarzynski, A.4
  • 12
    • 2942699378 scopus 로고    scopus 로고
    • Carl Zeiss Meditec AG. Data on file
    • Carl Zeiss Meditec AG. Data on file
  • 13
    • 0034832790 scopus 로고    scopus 로고
    • Influence of corneal curvature on calculation of ablation patterns used in photorefractive laser surgery
    • Mrochen M., Seiler T. Influence of corneal curvature on calculation of ablation patterns used in photorefractive laser surgery. J Refract Surg. 17(5):2001;S584-S587
    • (2001) J Refract Surg , vol.17 , Issue.5 , pp. 584-S587
    • Mrochen, M.1    Seiler, T.2
  • 16
    • 0033873480 scopus 로고    scopus 로고
    • A new arc-scanning very high-frequency ultrasound system for 3D pachymetric mapping of corneal epithelium, lamellar flap and residual stromal layer in laser in situ keratomileusis
    • Reinstein D.Z., Silverman R.H., Raevsky T., Simoni G.J., Lloyd H.O., Najafi D.J., et al. A new arc-scanning very high-frequency ultrasound system for 3D pachymetric mapping of corneal epithelium, lamellar flap and residual stromal layer in laser in situ keratomileusis. J Refract Surg. 16:2000;414-430
    • (2000) J Refract Surg , vol.16 , pp. 414-430
    • Reinstein, D.Z.1    Silverman, R.H.2    Raevsky, T.3    Simoni, G.J.4    Lloyd, H.O.5    Najafi, D.J.6
  • 17
    • 0033504309 scopus 로고    scopus 로고
    • Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: Anatomic diagnosis in lamellar surgery
    • Reinstein D.Z., Silverman R.H., Sutton H.F., Coleman D.J. Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: anatomic diagnosis in lamellar surgery. Ophthalmology. 106(3):1999;474-482
    • (1999) Ophthalmology , vol.106 , Issue.3 , pp. 474-482
    • Reinstein, D.Z.1    Silverman, R.H.2    Sutton, H.F.3    Coleman, D.J.4
  • 18
    • 0027427552 scopus 로고
    • High-frequency ultrasound measurement of the thickness of the corneal epithelium
    • Reinstein D.Z., Silverman R.H., Coleman D.J. High-frequency ultrasound measurement of the thickness of the corneal epithelium. Refract Corneal Surg. 9(5):1993;385-387
    • (1993) Refract Corneal Surg , vol.9 , Issue.5 , pp. 385-387
    • Reinstein, D.Z.1    Silverman, R.H.2    Coleman, D.J.3
  • 21
    • 0033898907 scopus 로고    scopus 로고
    • The cornea is not a piece of plastic
    • Roberts C. The cornea is not a piece of plastic. J Refract Surg. 16(4):2000;407-413
    • (2000) J Refract Surg , vol.16 , Issue.4 , pp. 407-413
    • Roberts, C.1
  • 22
    • 0036744718 scopus 로고    scopus 로고
    • Biomechanics of the cornea and wavefront-guided laser refractive surgery
    • Roberts C. Biomechanics of the cornea and wavefront-guided laser refractive surgery. J Refract Surg. 18(5):2002;S589-S592
    • (2002) J Refract Surg , vol.18 , Issue.5 , pp. 589-S592
    • Roberts, C.1
  • 23
    • 9344233901 scopus 로고    scopus 로고
    • Corneal asphericity following excimer laser photorefractive keratectomy. Summit PRK Topography Study Group
    • Hersh P.S., Shah S.I., Holladay J.T. Corneal asphericity following excimer laser photorefractive keratectomy. Summit PRK Topography Study Group. Ophthalmic Surg Lasers. 27(Suppl 5):1996;S421-S428
    • (1996) Ophthalmic Surg Lasers , vol.27 , Issue.SUPPL. 5 , pp. 421-S428
    • Hersh, P.S.1    Shah, S.I.2    Holladay, J.T.3
  • 24
    • 0036268407 scopus 로고    scopus 로고
    • Topographic changes in corneal asphericity and effective optical zone after laser in situ keratomileusis
    • Holladay J.T., Janes J.A. Topographic changes in corneal asphericity and effective optical zone after laser in situ keratomileusis. J Cataract Refract Surg. 28(6):2002;942-947
    • (2002) J Cataract Refract Surg , vol.28 , Issue.6 , pp. 942-947
    • Holladay, J.T.1    Janes, J.A.2
  • 25
    • 0031279198 scopus 로고    scopus 로고
    • Aberrations and retinal image quality of the normal human eye
    • Liang J., Williams D.R. Aberrations and retinal image quality of the normal human eye. J Opt Soc Am A. 14(11):1997;2873-2883
    • (1997) J Opt Soc Am a , vol.14 , Issue.11 , pp. 2873-2883
    • Liang, J.1    Williams, D.R.2
  • 27
    • 0027485510 scopus 로고
    • Model for predicting the optical performance of the eye in refractive surgery
    • Patel S., Marshall J., Fitzke F.W.D. Model for predicting the optical performance of the eye in refractive surgery. Refract Corneal Surg. 9(5):1993;366-375
    • (1993) Refract Corneal Surg , vol.9 , Issue.5 , pp. 366-375
    • Patel, S.1    Marshall, J.2    Fitzke, F.W.D.3
  • 28
    • 0027289494 scopus 로고
    • Aspheric photorefractive keratectomy with excimer laser
    • Seiler T., Genth U., Holschbach A., Derse M. Aspheric photorefractive keratectomy with excimer laser. Refract Corneal Surg. 9(3):1993;166-172
    • (1993) Refract Corneal Surg , vol.9 , Issue.3 , pp. 166-172
    • Seiler, T.1    Genth, U.2    Holschbach, A.3    Derse, M.4
  • 29
    • 2942699377 scopus 로고    scopus 로고
    • Prospective, controlled comparison of Hansatome vs. M2 aberrations: Can we control for flap induced aberrations in primary wavefront guided LASIK?
    • Nice (France);
    • Reinstein D.Z., Goes F. Prospective, controlled comparison of Hansatome vs. M2 aberrations: can we control for flap induced aberrations in primary wavefront guided LASIK? In: 20th Congress of the European Society of Cataract and Refractive Surgery. Nice (France); 2002
    • (2002) 20th Congress of the European Society of Cataract and Refractive Surgery
    • Reinstein, D.Z.1    Goes, F.2
  • 30
    • 0037345992 scopus 로고    scopus 로고
    • First clinical results with the femtosecond neodynium-glass laser in refractive surgery
    • Ratkay-Traub I., Ferincz I.E., Juhasz T., Kurtz R.M., Krueger R.R. First clinical results with the femtosecond neodynium-glass laser in refractive surgery. J Refract Surg. 19(2):2003;94-103
    • (2003) J Refract Surg , vol.19 , Issue.2 , pp. 94-103
    • Ratkay-Traub, I.1    Ferincz, I.E.2    Juhasz, T.3    Kurtz, R.M.4    Krueger, R.R.5
  • 35
    • 0036745758 scopus 로고    scopus 로고
    • First results with wavefront-guided photorefractive keratectomy for hyperopia
    • Nagy Z., Palágyi-Deak I., Kovács A., Kelemen E. First results with wavefront-guided photorefractive keratectomy for hyperopia. J Refract Surg. 18(5):2002;S620-S623
    • (2002) J Refract Surg , vol.18 , Issue.5 , pp. 620-S623
    • Nagy, Z.1    Palágyi-Deak, I.2    Kovács, A.3    Kelemen, E.4
  • 37
    • 0036268407 scopus 로고    scopus 로고
    • Topographic changes in corneal asphericity and effective optical zone after laser in situ keratomileusis
    • Holladay J.T., Janes J.A. Topographic changes in corneal asphericity and effective optical zone after laser in situ keratomileusis. J Cataract Refract Surg. 28(6):2002;942-947
    • (2002) J Cataract Refract Surg , vol.28 , Issue.6 , pp. 942-947
    • Holladay, J.T.1    Janes, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.