-
1
-
-
0043245066
-
The preparation and characterization of monomethoxypoly(ethylene glycol)b-poly-DL-lactide microcapsules containing bovine hemoglobin
-
Meng, F. T.; Zhang, W. Z.; Ma, G. H.; Su, Z. G. The preparation and characterization of monomethoxypoly(ethylene glycol)b-poly-DL-lactide microcapsules containing bovine hemoglobin. Artif. Cells, Blood Substitutes, Immobilization Biotechnol. 2003, 31, 279-292.
-
(2003)
Artif. Cells, Blood Substitutes, Immobilization Biotechnol.
, vol.31
, pp. 279-292
-
-
Meng, F.T.1
Zhang, W.Z.2
Ma, G.H.3
Su, Z.G.4
-
2
-
-
1142267294
-
Current development and use of hemoglobin-based oxygen-carrying (HBOC) solutions
-
Day, T. K. Current development and use of hemoglobin-based oxygen-carrying (HBOC) solutions. J. Vet. Em. Crit. Care 2003, 13, 77-93.
-
(2003)
J. Vet. Em. Crit. Care
, vol.13
, pp. 77-93
-
-
Day, T.K.1
-
3
-
-
0038129387
-
Arterial oxygenation and oxygen delivery after hemoglobin-based oxygen carrier infusion in canine hypovolemic shock: A dose-response study
-
Driessen, B.; Jahr, J. S.; Lurie, F.; Golkaryeh, M. S.; Gunther, R. A. Arterial oxygenation and oxygen delivery after hemoglobin-based oxygen carrier infusion in canine hypovolemic shock: A dose-response study. Crit. Care Med. 2003, 31, 1771-1779.
-
(2003)
Crit. Care Med.
, vol.31
, pp. 1771-1779
-
-
Driessen, B.1
Jahr, J.S.2
Lurie, F.3
Golkaryeh, M.S.4
Gunther, R.A.5
-
4
-
-
0038626776
-
Use of a human polymerized hemoglobin solution as an adjunct to acute normovolemic hemodilution during complex abdominal aortic reconstruction
-
Norris, E. J.; Ness, P. M.; Williams, G. M. Use of a human polymerized hemoglobin solution as an adjunct to acute normovolemic hemodilution during complex abdominal aortic reconstruction. J. Clin. Anesth. 2003, 15, 220-223.
-
(2003)
J. Clin. Anesth.
, vol.15
, pp. 220-223
-
-
Norris, E.J.1
Ness, P.M.2
Williams, G.M.3
-
5
-
-
0037989843
-
Artificial cells for replacement of metabolic organ functions
-
Chang, T. M. S. Artificial cells for replacement of metabolic organ functions. Artif. Cells, Blood Substitutes, Immobilization Biotechnol. 2003, 31, 151-161.
-
(2003)
Artif. Cells, Blood Substitutes, Immobilization Biotechnol.
, vol.31
, pp. 151-161
-
-
Chang, T.M.S.1
-
6
-
-
0347293197
-
The use of ultrapurified bovine hemoglobin solution in the treatment of two cases of presumed red maple toxicosis in a miniature horse and a pony
-
Vin, R.; Bedenice, D.; Rentko, V. T.; Paradis, M. R. The use of ultrapurified bovine hemoglobin solution in the treatment of two cases of presumed red maple toxicosis in a miniature horse and a pony. J. Vet. Em. Crit. Care 2002, 12, 169-175.
-
(2002)
J. Vet. Em. Crit. Care
, vol.12
, pp. 169-175
-
-
Vin, R.1
Bedenice, D.2
Rentko, V.T.3
Paradis, M.R.4
-
7
-
-
0037885022
-
Current status of blood substitute research: Towards a new paradigm
-
Winslow, R. M. Current status of blood substitute research: towards a new paradigm. J. Intern. Med. 2003, 253, 508-517.
-
(2003)
J. Intern. Med.
, vol.253
, pp. 508-517
-
-
Winslow, R.M.1
-
8
-
-
0034332499
-
125-albumin in the mouse
-
125-albumin in the mouse. Artif. Cells, Blood Substitutes, Immobilization Biotechnol. 2000, 28, 451-475.
-
(2000)
Artif. Cells, Blood Substitutes, Immobilization Biotechnol.
, vol.28
, pp. 451-475
-
-
Valeri, C.R.1
Ichikura, T.2
Pivacek, L.E.3
Giorgio, A.4
Prusty, S.5
Dittmer, J.6
-
9
-
-
0033792778
-
New features of renal lesion induced by stroma free hemoglobin
-
Chan, W. L.; Tang, N. L. S.; Yim, C. C. W.; Lai, F. M.; Tam, M. S. C. New features of renal lesion induced by stroma free hemoglobin. Toxicol. Pathol. 2000, 28, 635-642.
-
(2000)
Toxicol. Pathol.
, vol.28
, pp. 635-642
-
-
Chan, W.L.1
Tang, N.L.S.2
Yim, C.C.W.3
Lai, F.M.4
Tam, M.S.C.5
-
10
-
-
0029805358
-
Resuscitation and the limited utility of the present generation of blood substitutes
-
Hess, J. R.; Reiss, R. F. Resuscitation and the limited utility of the present generation of blood substitutes. Transfus. Med. Rev. 1996, 10, 276-285.
-
(1996)
Transfus. Med. Rev.
, vol.10
, pp. 276-285
-
-
Hess, J.R.1
Reiss, R.F.2
-
11
-
-
0024578683
-
In vivo distribution and elimination of hemoglobin modified by intramolecular cross-linking with 2-nor-2-formylpyridoxal 5′-phosphate
-
Bleeker, W. K.; Plas, J. V. D.; Feitsma, R. I. J.; Agterberg, J.; Rigter, G.; Rossen, A. D. V.-V.; Pauwels, E. K. J.; Bakker, J. C. In vivo distribution and elimination of hemoglobin modified by intramolecular cross-linking with 2-nor-2-formylpyridoxal 5′-phosphate. J. Lab. Clin. Med. 1989, 113, 151-161.
-
(1989)
J. Lab. Clin. Med.
, vol.113
, pp. 151-161
-
-
Bleeker, W.K.1
Plas, J.V.D.2
Feitsma, R.I.J.3
Agterberg, J.4
Rigter, G.5
Rossen, A.D.V.-V.6
Pauwels, E.K.J.7
Bakker, J.C.8
-
13
-
-
0034763199
-
Alpha adrenergic activation and hemoglobin mediated contraction in the isolated rat thoracic aorta
-
Kim, H. W.; Tai, J.; Greenburg, A. G. Alpha adrenergic activation and hemoglobin mediated contraction in the isolated rat thoracic aorta. Artif. Cells, Blood Substitutes, Immobilization Biotechnol. 2001, 29, 367-380.
-
(2001)
Artif. Cells, Blood Substitutes, Immobilization Biotechnol.
, vol.29
, pp. 367-380
-
-
Kim, H.W.1
Tai, J.2
Greenburg, A.G.3
-
14
-
-
0004055498
-
Renal effects of hemoglobin-based blood substitutes
-
Rudolph, A. S., Rabinovici, R., Feuerstein, G. Z., Eds.; Marcel Dekker: New York
-
Lieberthal, W. Renal effects of hemoglobin-based blood substitutes. In Red Blood Cell Substitutes; Rudolph, A. S., Rabinovici, R., Feuerstein, G. Z., Eds.; Marcel Dekker: New York, 1998; pp 189-217.
-
(1998)
Red Blood Cell Substitutes
, pp. 189-217
-
-
Lieberthal, W.1
-
15
-
-
0032914329
-
Histology and ultrastructure of liver and kidney following blood exchange with ultrapurified, polymerised bovine hemoglobin in comparison with hydroxyethyl starch
-
Lipfert, B.; Standl, T.; Dullmann, J.; Helmchen, U.; Esch, J. S. A.; Lorke, D. E. Histology and ultrastructure of liver and kidney following blood exchange with ultrapurified, polymerised bovine hemoglobin in comparison with hydroxyethyl starch. Lab. Invest. 1999, 79, 573-582.
-
(1999)
Lab. Invest.
, vol.79
, pp. 573-582
-
-
Lipfert, B.1
Standl, T.2
Dullmann, J.3
Helmchen, U.4
Esch, J.S.A.5
Lorke, D.E.6
-
16
-
-
0035465476
-
Oxygen carriers
-
Riess, J. Oxygen carriers. Chem. Rev. 2001, 101, 2797-2919.
-
(2001)
Chem. Rev.
, vol.101
, pp. 2797-2919
-
-
Riess, J.1
-
17
-
-
0032247470
-
Vasoactive properties of synthetic blood substitutes
-
De Figueiredo, L. F. P. Vasoactive properties of synthetic blood substitutes. Medicina (Buenos Aires) 1998, 58, 403-410.
-
(1998)
Medicina (Buenos Aires)
, vol.58
, pp. 403-410
-
-
De Figueiredo, L.F.P.1
-
18
-
-
0001517449
-
Pulmonary hypertension and systemic vasoconstriction may offset the benefits of acellular hemoglobin blood substitutes
-
deFigueiredo, L. F. P.; Mathru, M.; Solanki, D.; MacDonald, V. W.; Hess, J.; Kramer, G. C. Pulmonary hypertension and systemic vasoconstriction may offset the benefits of acellular hemoglobin blood substitutes. J. Trauma: Inj., Infect., Crit. Care 1997, 42, 847-854.
-
(1997)
J. Trauma: Inj., Infect., Crit. Care
, vol.42
, pp. 847-854
-
-
Defigueiredo, L.F.P.1
Mathru, M.2
Solanki, D.3
MacDonald, V.W.4
Hess, J.5
Kramer, G.C.6
-
19
-
-
0030374161
-
Hemoglobin-induced contraction of pig pulmonary veins
-
Muldoon, S. M.; Ledvina, M. A.; Hart, J. L.; MacDonald, V. W. Hemoglobin-induced contraction of pig pulmonary veins. J. Lab. Clin. Med. 1996, 128, 579-583.
-
(1996)
J. Lab. Clin. Med.
, vol.128
, pp. 579-583
-
-
Muldoon, S.M.1
Ledvina, M.A.2
Hart, J.L.3
MacDonald, V.W.4
-
20
-
-
0036899267
-
The polymerized bovine hemoglobin-based oxygen-carrying solution (HBOC-201) is not toxic to neural cells in culture
-
Ortegon, D. P.; Davis, M. R.; Dixon, P. S.; Smith, D. L.; Josephs, J. D.; Mueller, D. L.; Jenkins, D. H.; Kerby, J. D. The polymerized bovine hemoglobin-based oxygen-carrying solution (HBOC-201) is not toxic to neural cells in culture. J. Trauma: Inj., Infect., Crit. Care 2002, 53, 1068-1072.
-
(2002)
J. Trauma: Inj., Infect., Crit. Care
, vol.53
, pp. 1068-1072
-
-
Ortegon, D.P.1
Davis, M.R.2
Dixon, P.S.3
Smith, D.L.4
Josephs, J.D.5
Mueller, D.L.6
Jenkins, D.H.7
Kerby, J.D.8
-
21
-
-
0002116336
-
Interactions of hemoglobin with the central nervous system
-
Rudolph, A. S., Rabinovici, R., Feuerstein, G. Z., Eds.; Marcel Dekker: New York
-
Panter, S. S.; Regan, R. F. Interactions of hemoglobin with the central nervous system. In Red Blood Cell Substitutes; Rudolph, A. S., Rabinovici, R., Feuerstein, G. Z., Eds.; Marcel Dekker: New York, 1998; pp 219-235.
-
(1998)
Red Blood Cell Substitutes
, pp. 219-235
-
-
Panter, S.S.1
Regan, R.F.2
-
22
-
-
0027298460
-
Neurotoxicity of hemoglobin in cortical cell culture
-
Regan, R. F.; Panter, S. S. Neurotoxicity of hemoglobin in cortical cell culture. Neurosci. Lett. 1993, 153, 219-222.
-
(1993)
Neurosci. Lett.
, vol.153
, pp. 219-222
-
-
Regan, R.F.1
Panter, S.S.2
-
23
-
-
0036290272
-
Preparation of well-defined bovine polyhemoglobin based on dimethyl adipimidate and glutaraldehyde cross-linkage
-
Hu, T.; Su, Z. G. Preparation of well-defined bovine polyhemoglobin based on dimethyl adipimidate and glutaraldehyde cross-linkage. Biochem. Biophys. Res. Commun. 2002, 293, 958-961.
-
(2002)
Biochem. Biophys. Res. Commun.
, vol.293
, pp. 958-961
-
-
Hu, T.1
Su, Z.G.2
-
24
-
-
27244461652
-
Effects of glutaraldehyde polymerization on oxygen transport and redox properties of bovine hemoglobin
-
Alayash, A. I.; Summers, A. G.; Wood, F.; Jia, Y. P. Effects of glutaraldehyde polymerization on oxygen transport and redox properties of bovine hemoglobin. Arch. Biochem. Biophys. 2001, 391, 225-234.
-
(2001)
Arch. Biochem. Biophys.
, vol.391
, pp. 225-234
-
-
Alayash, A.I.1
Summers, A.G.2
Wood, F.3
Jia, Y.P.4
-
25
-
-
0033984989
-
Synthesis and physicochemical characterization of a series of hemoglobin-based oxygen carriers: Objective comparison between cellular and acellular types
-
Sakai, H.; Yuasa, M.; Onuma, H.; Takeoka, S.; Tsuchida, E. Synthesis and physicochemical characterization of a series of hemoglobin-based oxygen carriers: Objective comparison between cellular and acellular types. Bioconjugate Chem. 2000, 11, 56-64.
-
(2000)
Bioconjugate Chem.
, vol.11
, pp. 56-64
-
-
Sakai, H.1
Yuasa, M.2
Onuma, H.3
Takeoka, S.4
Tsuchida, E.5
-
26
-
-
0033593343
-
Glutaraldehyde modification of recombinant human hemoglobin alters its hemodynamic properties
-
Doyle, M. P.; Apostol, I.; Kerwin, B. A. Glutaraldehyde modification of recombinant human hemoglobin alters its hemodynamic properties. J. Biol. Chem. 1999, 274, 2583-2591.
-
(1999)
J. Biol. Chem.
, vol.274
, pp. 2583-2591
-
-
Doyle, M.P.1
Apostol, I.2
Kerwin, B.A.3
-
27
-
-
0026646554
-
A critical review of the toxicology of glutaraldehyde
-
Beauchamp, R. O.; Clair, M. B. G. S.; Fennell, T. R.; Clarke, D. O.; Morgan, K. T. A critical review of the toxicology of glutaraldehyde. Crit. Rev. Toxicol. 1992, 22, 143-174.
-
(1992)
Crit. Rev. Toxicol.
, vol.22
, pp. 143-174
-
-
Beauchamp, R.O.1
Clair, M.B.G.S.2
Fennell, T.R.3
Clarke, D.O.4
Morgan, K.T.5
-
28
-
-
0027176899
-
Chromatographic analysis of biopolymers distribution in "poly-hemoglobin", an inter-molecularly cross-linked hemoglobin solution
-
Simoni, J.; Simoni, G.; Feola, M. Chromatographic analysis of biopolymers distribution in "poly-hemoglobin", an inter-molecularly cross-linked hemoglobin solution. Anal. Chim. Acta 1993, 279, 73-88.
-
(1993)
Anal. Chim. Acta
, vol.279
, pp. 73-88
-
-
Simoni, J.1
Simoni, G.2
Feola, M.3
-
29
-
-
0037240255
-
Alteration of the postinjury hyperinflammatory response by means of resuscitation with a red cell substitute
-
Johnson, J. L.; Moore, E. E.; Gonzalez, R. J.; Fedel, N.; Partrick, D. A.; Silliman, C. C. Alteration of the postinjury hyperinflammatory response by means of resuscitation with a red cell substitute. J. Trauma: Inj., Infect., Crit. Care 2003, 54, 133-139.
-
(2003)
J. Trauma: Inj., Infect., Crit. Care
, vol.54
, pp. 133-139
-
-
Johnson, J.L.1
Moore, E.E.2
Gonzalez, R.J.3
Fedel, N.4
Partrick, D.A.5
Silliman, C.C.6
-
30
-
-
0036832020
-
Polymerized human Hb use in acute chest syndrome: A case report
-
Lanzkron, S.; Moliterno, A. R.; Norris, E. J.; Gould, S. A.; Segal, J.; Nuermberger, E. L.; Ness, P. M. Polymerized human Hb use in acute chest syndrome: a case report. Transfusion 2002, 42, 1422-1427.
-
(2002)
Transfusion
, vol.42
, pp. 1422-1427
-
-
Lanzkron, S.1
Moliterno, A.R.2
Norris, E.J.3
Gould, S.A.4
Segal, J.5
Nuermberger, E.L.6
Ness, P.M.7
-
31
-
-
0036789874
-
The life-sustaining capacity of human polymerized hemoglobin when red cells might be unavailable
-
Gould, S. A.; Moore, E. E.; Hoyt, D. B.; Ness, P. M.; Norris, E. J.; Carson, J. L.; Hides, G. A.; Freeman, I. H. G.; DeWoskin, R.; Moss, G. S. The life-sustaining capacity of human polymerized hemoglobin when red cells might be unavailable. J. Am. Coll. Surg. 2002, 195, 445-452.
-
(2002)
J. Am. Coll. Surg.
, vol.195
, pp. 445-452
-
-
Gould, S.A.1
Moore, E.E.2
Hoyt, D.B.3
Ness, P.M.4
Norris, E.J.5
Carson, J.L.6
Hides, G.A.7
Freeman, I.H.G.8
Dewoskin, R.9
Moss, G.S.10
-
32
-
-
0036658336
-
Polymerized bovine hemoglobin solution as a replacement for allogeneic red blood cell transfusion after cardiac surgery: Results of a randomized, double-blind trial
-
Levy, J. H.; Goodnough, L. T.; Greilich, P. E.; Parr, G. V. S.; Stewart, R. W.; Gratz, I.; Wahr, J.; Williams, J.; Comunale, M. E.; Doblar, D.; Silvay, G.; Cohen, M.; Jahr, J. S.; Vlahakes, G. J. Polymerized bovine hemoglobin solution as a replacement for allogeneic red blood cell transfusion after cardiac surgery: Results of a randomized, double-blind trial. J. Thorac. Cardiovasc. Surg. 2002, 124, 35-42.
-
(2002)
J. Thorac. Cardiovasc. Surg.
, vol.124
, pp. 35-42
-
-
Levy, J.H.1
Goodnough, L.T.2
Greilich, P.E.3
Parr, G.V.S.4
Stewart, R.W.5
Gratz, I.6
Wahr, J.7
Williams, J.8
Comunale, M.E.9
Doblar, D.10
Silvay, G.11
Cohen, M.12
Jahr, J.S.13
Vlahakes, G.J.14
-
33
-
-
0038479061
-
Transfusion requirements in phase III study of HBOC-201 (Hemopure, hemoglobin glutamer-250, bovine), a bovine hemoglobin based blood substitute
-
Williams, J. P.; Tseuda, K.; Vandermeersch, E.; Bourke, D. L.; Jahr, J. S. Transfusion requirements in phase III study of HBOC-201 (Hemopure, hemoglobin glutamer-250, bovine), a bovine hemoglobin based blood substitute. Transfusion 2002, 42, 14S-14S.
-
(2002)
Transfusion
, vol.42
-
-
Williams, J.P.1
Tseuda, K.2
Vandermeersch, E.3
Bourke, D.L.4
Jahr, J.S.5
-
34
-
-
0027050127
-
Amadori rearrangement potential of hemoglobin at its glycation sites is dependent on the 3-dimensional structure of protein
-
Nacharaju, P.; Acharya, A. S. Amadori rearrangement potential of hemoglobin at its glycation sites is dependent on the 3-dimensional structure of protein. Biochemistry 1992, 31, 12673-12679.
-
(1992)
Biochemistry
, vol.31
, pp. 12673-12679
-
-
Nacharaju, P.1
Acharya, A.S.2
-
35
-
-
0025892155
-
Aldimine to ketoamine isomerization (amadori rearrangement) potential at the individual nonenzymic glycation sites of hemoglobin-a - Preferential inhibition of glycation by nucleophiles at sites of low isomerization potential
-
Acharya, A. S.; Roy, R. P.; Dorai, B. Aldimine to ketoamine isomerization (amadori rearrangement) potential at the individual nonenzymic glycation sites of hemoglobin-a - preferential inhibition of glycation by nucleophiles at sites of low isomerization potential. J. Protein Chem. 1991, 10, 345-358.
-
(1991)
J. Protein Chem.
, vol.10
, pp. 345-358
-
-
Acharya, A.S.1
Roy, R.P.2
Dorai, B.3
-
36
-
-
0017600486
-
Characterisitcs of stroma-free hemoglobin prepared by crystallization
-
DeVenuto, F.; Zuck, T. F.; Zegna, A. I.; Moores, W. Y. Characterisitcs of stroma-free hemoglobin prepared by crystallization. J. Lab. Clin. Med. 1977, 89, 509-516.
-
(1977)
J. Lab. Clin. Med.
, vol.89
, pp. 509-516
-
-
DeVenuto, F.1
Zuck, T.F.2
Zegna, A.I.3
Moores, W.Y.4
-
38
-
-
0347413685
-
Determination of size distribution and encapsulation efficiency of liposome encapsulated hemoglobin blood substitutes using asymmetric flow field-flow fractionation coupled with multi-angle light scattering
-
Arifin, D. R.; Palmer, A. F. Determination of size distribution and encapsulation efficiency of liposome encapsulated hemoglobin blood substitutes using asymmetric flow field-flow fractionation coupled with multi-angle light scattering. Biotechnol. Prog. 2003, 19, 1798-1811.
-
(2003)
Biotechnol. Prog.
, vol.19
, pp. 1798-1811
-
-
Arifin, D.R.1
Palmer, A.F.2
-
39
-
-
0034663390
-
The influence of temperature on the characterization of water-soluble polymers using asymmetric flow field-flow-fractionation couple to multiangle laser light scattering
-
Viebke, C.; Williams, P. A. The influence of temperature on the characterization of water-soluble polymers using asymmetric flow field-flow-fractionation couple to multiangle laser light scattering. Anal. Chem. 2000, 72, 3896-3901.
-
(2000)
Anal. Chem.
, vol.72
, pp. 3896-3901
-
-
Viebke, C.1
Williams, P.A.2
-
40
-
-
0035886666
-
Ultrahigh molar mass component detected in ethylhydroxylethyl cellulose by asymmetric flow field-flow fractionation coupled to multiangle light scattering
-
Andersson, M.; Wittgren, B.; Wahlund, K.-G. Ultrahigh molar mass component detected in ethylhydroxylethyl cellulose by asymmetric flow field-flow fractionation coupled to multiangle light scattering. Anal. Chem. 2001, 73, 4852-4861.
-
(2001)
Anal. Chem.
, vol.73
, pp. 4852-4861
-
-
Andersson, M.1
Wittgren, B.2
Wahlund, K.-G.3
-
41
-
-
0020694805
-
Preparation and evaluation of pyridoxalated-polymerized human hemoglobin
-
DeVenuto, F.; Zegna, A. Preparation and evaluation of pyridoxalated-polymerized human hemoglobin. J. Surg. Res. 1983, 34, 205-212.
-
(1983)
J. Surg. Res.
, vol.34
, pp. 205-212
-
-
DeVenuto, F.1
Zegna, A.2
|