메뉴 건너뛰기




Volumn 23, Issue 6, 2004, Pages 821-828

Angiographic power 3-dimensional quantitative analysis in gynecologic solid tumors: Feasibility and reproducibility

Author keywords

3 dimensional power Doppler sonography; 3 dimensional sonography; Angiogenesis; Transvaginal color Doppler sonography; Transvaginal sonography

Indexed keywords

ANGIOGRAPHY; CORRELATION METHODS; DOPPLER EFFECT; GYNECOLOGY; IMAGE ANALYSIS; PATIENT MONITORING;

EID: 2942623549     PISSN: 02784297     EISSN: None     Source Type: Journal    
DOI: 10.7863/jum.2004.23.6.821     Document Type: Article
Times cited : (12)

References (25)
  • 1
    • 0037106374 scopus 로고    scopus 로고
    • Mechanisms and future directions for angiogenesis-based cancer therapies
    • Scappaticci FA. Mechanisms and future directions for angiogenesis-based cancer therapies. J Clin Oncol 2002; 20:3906-3927.
    • (2002) J Clin Oncol , vol.20 , pp. 3906-3927
    • Scappaticci, F.A.1
  • 2
    • 0033982797 scopus 로고    scopus 로고
    • Sonographic depiction of tumor vascularity and flow: From in vivo models to clinical applications
    • Fleischer AC. Sonographic depiction of tumor vascularity and flow: from in vivo models to clinical applications. J Ultrasound Med 2000; 19:55-61.
    • (2000) J Ultrasound Med , vol.19 , pp. 55-61
    • Fleischer, A.C.1
  • 3
    • 0037112419 scopus 로고    scopus 로고
    • High-frequency Doppler ultrasound monitors the effects the antivascular therapy on tumor blood flow
    • Goertz DE, Yu JL, Kerbel RS, Burns PN, Foster FS. High-frequency Doppler ultrasound monitors the effects the antivascular therapy on tumor blood flow. Cancer Res 2002; 62:6371-6375.
    • (2002) Cancer Res , vol.62 , pp. 6371-6375
    • Goertz, D.E.1    Yu, J.L.2    Kerbel, R.S.3    Burns, P.N.4    Foster, F.S.5
  • 4
    • 0033767777 scopus 로고    scopus 로고
    • Power Doppler angiographic appearance and blood flow velocity waveforms in invasive cervical carcinoma
    • Wu Y, Yuan C, Hung J, Chao K, Yen M, Ng H. Power Doppler angiographic appearance and blood flow velocity waveforms in invasive cervical carcinoma. Gynecol Oncol 2000; 79:181-186.
    • (2000) Gynecol Oncol , vol.79 , pp. 181-186
    • Wu, Y.1    Yuan, C.2    Hung, J.3    Chao, K.4    Yen, M.5    Ng, H.6
  • 5
    • 0030025870 scopus 로고    scopus 로고
    • Early detection of ovarian carcinoma with transvaginal color Doppler ultrasonography
    • Fleisher AC, Cullinan JA, Peery CV, Jones HW III. Early detection of ovarian carcinoma with transvaginal color Doppler ultrasonography. Am J Obstet Gynecol 1996; 174:101-106.
    • (1996) Am J Obstet Gynecol , vol.174 , pp. 101-106
    • Fleisher, A.C.1    Cullinan, J.A.2    Peery, C.V.3    Jones III, H.W.4
  • 6
    • 0030060331 scopus 로고    scopus 로고
    • Transvaginal color Doppler ultrasound in the assessment of invasive cervical carcinoma
    • Tepper R, Zalel Y, Altaras M, Ben-Baruch G, Beyth Y. Transvaginal color Doppler ultrasound in the assessment of invasive cervical carcinoma. Gynecol Oncol 1996; 60:26-29.
    • (1996) Gynecol Oncol , vol.60 , pp. 26-29
    • Tepper, R.1    Zalel, Y.2    Altaras, M.3    Ben-Baruch, G.4    Beyth, Y.5
  • 7
    • 0028999572 scopus 로고
    • Clinical significance of intratumoral blood flow in cervical carcinoma assessed by color Doppler ultrasound
    • Hsieh CY, Wu CC, Chen TM, et al. Clinical significance of intratumoral blood flow in cervical carcinoma assessed by color Doppler ultrasound. Cancer 1995; 75:2518-2522.
    • (1995) Cancer , vol.75 , pp. 2518-2522
    • Hsieh, C.Y.1    Wu, C.C.2    Chen, T.M.3
  • 8
    • 0032684558 scopus 로고    scopus 로고
    • Transvaginal color Doppler for predicting pathological response to preoperative chemoradiation in locally advanced cervical carcinoma: A preliminary study
    • Alcazar JL, Jurado M. Transvaginal color Doppler for predicting pathological response to preoperative chemoradiation in locally advanced cervical carcinoma: a preliminary study. Ultrasound Med Biol 1999; 25:1041-1045.
    • (1999) Ultrasound Med Biol , vol.25 , pp. 1041-1045
    • Alcazar, J.L.1    Jurado, M.2
  • 9
    • 0029016896 scopus 로고
    • Effects of external radiotherapy on uterine blood flow in patients with advanced cervical carcinoma assessed by color Doppler ultrasonography
    • Pirhonen JP, Grenman SA, Bredbacka AB, Bahado-Singh RO, Salmi TA. Effects of external radiotherapy on uterine blood flow in patients with advanced cervical carcinoma assessed by color Doppler ultrasonography. Cancer 1995; 76:67-71.
    • (1995) Cancer , vol.76 , pp. 67-71
    • Pirhonen, J.P.1    Grenman, S.A.2    Bredbacka, A.B.3    Bahado-Singh, R.O.4    Salmi, T.A.5
  • 10
    • 0031045186 scopus 로고    scopus 로고
    • Transvaginal color Doppler ultrasound for monitoring the response to neoadjuvant chemotherapy in advanced cervical cancer
    • Greco P, Cormio G, Vimercati A, et al. Transvaginal color Doppler ultrasound for monitoring the response to neoadjuvant chemotherapy in advanced cervical cancer. Acta Obstet Gynecol Scand 1997; 76:169-172.
    • (1997) Acta Obstet Gynecol Scand , vol.76 , pp. 169-172
    • Greco, P.1    Cormio, G.2    Vimercati, A.3
  • 11
    • 0031954096 scopus 로고    scopus 로고
    • 3D color power Angio imaging: A new method to assess intracervical vascularization in benign and pathological conditions
    • Suren A, Osmers R, Kuhn W. 3D color power Angio imaging: a new method to assess intracervical vascularization in benign and pathological conditions. Ultrasound Obstet Gynecol 1998; 11:133-137.
    • (1998) Ultrasound Obstet Gynecol , vol.11 , pp. 133-137
    • Suren, A.1    Osmers, R.2    Kuhn, W.3
  • 12
    • 0032841809 scopus 로고    scopus 로고
    • Three-dimensional power Doppler sonography: Imaging and quantifying blood flow and vascularization
    • Pairleitner H, Steiner H, Hasenoehrl G, Staudach A. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization. Ultrasound Obstet Gynecol 1999; 14:139-143.
    • (1999) Ultrasound Obstet Gynecol , vol.14 , pp. 139-143
    • Pairleitner, H.1    Steiner, H.2    Hasenoehrl, G.3    Staudach, A.4
  • 14
    • 0344211435 scopus 로고    scopus 로고
    • Intraobserver and interobserver variability of ovarian volume, gray-scale and color flow indices obtained using transvaginal three-dimensional power Doppler ultrasonography
    • Jarvela IY, Sladkevicius P, Tekay AH, Campbell S, Nargund G. Intraobserver and interobserver variability of ovarian volume, gray-scale and color flow indices obtained using transvaginal three-dimensional power Doppler ultrasonography. Ultrasound Obstet Gynecol 2003; 21:277-282.
    • (2003) Ultrasound Obstet Gynecol , vol.21 , pp. 277-282
    • Jarvela, I.Y.1    Sladkevicius, P.2    Tekay, A.H.3    Campbell, S.4    Nargund, G.5
  • 15
    • 0031106790 scopus 로고    scopus 로고
    • Gray scale sonography, subjective evaluation of the color Doppler image and measurement of blood flow velocity for distinguish benign and malignant tumors of suspected adnexal origin
    • Valentin L. Gray scale sonography, subjective evaluation of the color Doppler image and measurement of blood flow velocity for distinguish benign and malignant tumors of suspected adnexal origin. Eur J Obstet Gynecol 1997; 72:63-72.
    • (1997) Eur J Obstet Gynecol , vol.72 , pp. 63-72
    • Valentin, L.1
  • 16
    • 0036098431 scopus 로고    scopus 로고
    • Detection of central pelvic recurrent disease with transvaginal color Doppler ultrasound in women treated for gynecological malignancy
    • Testa AC, Ciampelli M, Mastromarino C, et al. Detection of central pelvic recurrent disease with transvaginal color Doppler ultrasound in women treated for gynecological malignancy. Ultrasound Obstet Gynecol 2002; 19:490-495.
    • (2002) Ultrasound Obstet Gynecol , vol.19 , pp. 490-495
    • Testa, A.C.1    Ciampelli, M.2    Mastromarino, C.3
  • 17
    • 0034487466 scopus 로고    scopus 로고
    • Terms, definitions and measurements to describe the sonographic features of adnexal tumors: A consensus opinion from the International Ovarian Tumor Analysis (IOTA) Group
    • Timmerman D, Valentin L, Bourne TH, et al. Terms, definitions and measurements to describe the sonographic features of adnexal tumors: a consensus opinion from the International Ovarian Tumor Analysis (IOTA) Group. Ultrasound Obstet Gynecol 2000; 16:500-505.
    • (2000) Ultrasound Obstet Gynecol , vol.16 , pp. 500-505
    • Timmerman, D.1    Valentin, L.2    Bourne, T.H.3
  • 18
    • 0027478523 scopus 로고
    • Intra-observer and inter-observer reliability of the pulsatility index calculated from pulsed Doppler flow velocity waveforms in three fetal vessels
    • Sherjon SA, Kok JH, Oosting H, Zondervan HA. Intra-observer and inter-observer reliability of the pulsatility index calculated from pulsed Doppler flow velocity waveforms in three fetal vessels. Br J Obstet Gynaecol 1993; 100:134-138.
    • (1993) Br J Obstet Gynaecol , vol.100 , pp. 134-138
    • Sherjon, S.A.1    Kok, J.H.2    Oosting, H.3    Zondervan, H.A.4
  • 19
    • 0019432398 scopus 로고
    • Clinical biostatistics: The biostatistics of concordance
    • Kramer MS, Feinstein AR. Clinical biostatistics: the biostatistics of concordance. Clin Pharmacol Ther 1981; 29:111-123.
    • (1981) Clin Pharmacol Ther , vol.29 , pp. 111-123
    • Kramer, M.S.1    Feinstein, A.R.2
  • 20
    • 0036434351 scopus 로고    scopus 로고
    • Intraobserver and interobserver reproducibility of ultrasound measurements of endometrial thickness in postmenopausal women
    • Epstein E, Valentin L. Intraobserver and interobserver reproducibility of ultrasound measurements of endometrial thickness in postmenopausal women. Ultrasound Obstet Gynecol 2002; 20:486-491.
    • (2002) Ultrasound Obstet Gynecol , vol.20 , pp. 486-491
    • Epstein, E.1    Valentin, L.2
  • 21
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 0025048927 scopus 로고
    • A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurements
    • Bland JM, Altman DG. A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurements. Comput Biol Med 1990; 20:337-340.
    • (1990) Comput Biol Med , vol.20 , pp. 337-340
    • Bland, J.M.1    Altman, D.G.2
  • 24
    • 0025763588 scopus 로고
    • The current status of maternal and fetal blood flow velocimetry
    • Low JA. The current status of maternal and fetal blood flow velocimetry. Am J Obstet Gynecol 1991; 164:1049-1063.
    • (1991) Am J Obstet Gynecol , vol.164 , pp. 1049-1063
    • Low, J.A.1
  • 25
    • 0024539009 scopus 로고
    • Intraobserver variation in Doppler ultrasound indices of placental perfusion derived from different numbers of waveforms
    • Spencer JAD, Price J. Intraobserver variation in Doppler ultrasound indices of placental perfusion derived from different numbers of waveforms. J Ultrasound Med 1989; 8:197-199.
    • (1989) J Ultrasound Med , vol.8 , pp. 197-199
    • Spencer, J.A.D.1    Price, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.