메뉴 건너뛰기




Volumn 59, Issue 6, 2004, Pages 883-890

Use of a parallel path nebulizer for capillary-based microseparation techniques coupled with an inductively coupled plasma mass spectrometer for speciation measurements

Author keywords

CE; Cobalamins; ICP MS; Micro HPLC; Microseparation; Mira Mist CE nebulizer; Parallel path nebulizer; Speciation; Vitamin B12

Indexed keywords

ABSORPTION; AEROSOLS; CAPILLARY FLOW; DATA ACQUISITION; DEMODULATION; ELECTROPHORESIS; HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; INDUCTIVELY COUPLED PLASMA; PLASMA FLOW; TOXICITY;

EID: 2942545908     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sab.2004.03.005     Document Type: Article
Times cited : (44)

References (24)
  • 1
    • 0031998077 scopus 로고    scopus 로고
    • Speciation of trace elements in foods, with special reference to cadmium and selenium: Is it necessary?
    • Crews H.M. Speciation of trace elements in foods, with special reference to cadmium and selenium: is it necessary? Spectrochim. Acta Part B. 53:1998;213-219.
    • (1998) Spectrochim. Acta Part B , vol.53 , pp. 213-219
    • Crews, H.M.1
  • 2
    • 0343593725 scopus 로고    scopus 로고
    • The role of speciation in analytical chemistry
    • Kot A., Maniesńik J. The role of speciation in analytical chemistry. Trends Anal. Chem. 19:2000;69-79.
    • (2000) Trends Anal. Chem. , vol.19 , pp. 69-79
    • Kot, A.1    Maniesńik, J.2
  • 3
    • 0031997066 scopus 로고    scopus 로고
    • Speciation analysis: Where is it going? An a attempt at a forecast
    • Welz B. Speciation analysis: where is it going? An a attempt at a forecast. Spectrochim. Acta Part B. 53:1998;169-175.
    • (1998) Spectrochim. Acta Part B , vol.53 , pp. 169-175
    • Welz, B.1
  • 4
    • 0031458062 scopus 로고    scopus 로고
    • Inductively coupled plasma mass spectrometric detection for chromatography and capillary electrophoresis
    • Sutton K.L., Sutton R.M.C., Caruso J.A. Inductively coupled plasma mass spectrometric detection for chromatography and capillary electrophoresis. J. Chromatogr., A. 789:1997;85-126.
    • (1997) J. Chromatogr., A , vol.789 , pp. 85-126
    • Sutton, K.L.1    Sutton, R.M.C.2    Caruso, J.A.3
  • 5
    • 0034270997 scopus 로고    scopus 로고
    • A comparison of nebulizers for microbore LC-ICP-MS with mobile phases containing methanol
    • Ackley K.L., Sutton K.L., Caruso J.A. A comparison of nebulizers for microbore LC-ICP-MS with mobile phases containing methanol. J. Anal. At. Spectrom. 15:2000;1069-1073.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 1069-1073
    • Ackley, K.L.1    Sutton, K.L.2    Caruso, J.A.3
  • 6
    • 0031163764 scopus 로고    scopus 로고
    • Microconcentric nebulizer for the coupling of micro liquid chromatography and capillary zone electrophoresis with inductively coupled plasma mass spectrometry
    • Tangen A., Trones R., Greibrokk T., Lund W. Microconcentric nebulizer for the coupling of micro liquid chromatography and capillary zone electrophoresis with inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 12:1997;667-670.
    • (1997) J. Anal. At. Spectrom. , vol.12 , pp. 667-670
    • Tangen, A.1    Trones, R.2    Greibrokk, T.3    Lund, W.4
  • 7
    • 0037045226 scopus 로고    scopus 로고
    • Optimization of the hyphenation between capillary zone electrophoresis and inductively coupled plasma mass spectrometry for the measurement of As-, Sb-, Se-, and Te-species, applicable to soil extracts
    • Casiot C., Donard O.F.X., Potin-Gautier M. Optimization of the hyphenation between capillary zone electrophoresis and inductively coupled plasma mass spectrometry for the measurement of As-, Sb-, Se-, and Te-species, applicable to soil extracts. Spectrochim. Acta Part B. 57:2002;173-187.
    • (2002) Spectrochim. Acta Part B , vol.57 , pp. 173-187
    • Casiot, C.1    Donard, O.F.X.2    Potin-Gautier, M.3
  • 8
    • 0032182158 scopus 로고    scopus 로고
    • Design and characterization of a microconcentric nebulizer interface for capillary electrophoresis-inductively coupled plasma mass spectrometry
    • Taylor K.A., Sharp B.L., Lewis D.J., Crews H.M. Design and characterization of a microconcentric nebulizer interface for capillary electrophoresis-inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 13:1998;1095-1100.
    • (1998) J. Anal. At. Spectrom. , vol.13 , pp. 1095-1100
    • Taylor, K.A.1    Sharp, B.L.2    Lewis, D.J.3    Crews, H.M.4
  • 9
    • 0035121284 scopus 로고    scopus 로고
    • Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation
    • Bendahl L., Gammelgaard B., Jøns O., Farver O., Hansen S.H. Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation. J. Anal. At. Spectrom. 16:2001;38-42.
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 38-42
    • Bendahl, L.1    Gammelgaard, B.2    Jøns, O.3    Farver, O.4    Hansen, S.H.5
  • 10
    • 0038146944 scopus 로고    scopus 로고
    • Characterization of microconcentric nebulizer uptake rates for capillary electrophoresis inductively coupled plasma mass spectrometry
    • Yanes E.G., Miller-Ihli N.J. Characterization of microconcentric nebulizer uptake rates for capillary electrophoresis inductively coupled plasma mass spectrometry. Spectrochim. Acta Part B. 58:2003;949-955.
    • (2003) Spectrochim. Acta Part B , vol.58 , pp. 949-955
    • Yanes, E.G.1    Miller-Ihli, N.J.2
  • 11
    • 0001450954 scopus 로고    scopus 로고
    • Effect of laminar flow in capillary electrophoresis: Model and experimental results on controlling analysis time and resolution with inductively coupled plasma mass spectrometry detection
    • Kinzer J.A., Olesik J.W., Olesik S.V. Effect of laminar flow in capillary electrophoresis: model and experimental results on controlling analysis time and resolution with inductively coupled plasma mass spectrometry detection. Anal. Chem. 68:1996;3250-3257.
    • (1996) Anal. Chem. , vol.68 , pp. 3250-3257
    • Kinzer, J.A.1    Olesik, J.W.2    Olesik, S.V.3
  • 12
    • 0032167074 scopus 로고    scopus 로고
    • Transient acid effects in inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry
    • Stewart I.I., Olesik J.W. Transient acid effects in inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 13:1998;843-854.
    • (1998) J. Anal. At. Spectrom. , vol.13 , pp. 843-854
    • Stewart, I.I.1    Olesik, J.W.2
  • 13
    • 0033717616 scopus 로고    scopus 로고
    • Effect of the spray chamber design on steady and transient acid interferences in inductively coupled plasma atomic emission spectrometry
    • Todolí J.L., Mermet J.M. Effect of the spray chamber design on steady and transient acid interferences in inductively coupled plasma atomic emission spectrometry. J. Anal. At. Spectrom. 15:2000;863-867.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 863-867
    • Todolí, J.L.1    Mermet, J.M.2
  • 14
    • 0037500766 scopus 로고    scopus 로고
    • Non-spectral interference effects in inductively coupled plasma mass spectrometry using direct injection high efficiency and microconcentric nebulization
    • Björn E., Frech W. Non-spectral interference effects in inductively coupled plasma mass spectrometry using direct injection high efficiency and microconcentric nebulization. J. Anal. At. Spectrom. 16:2001;4-11.
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 4-11
    • Björn, E.1    Frech, W.2
  • 15
    • 0029126097 scopus 로고
    • Speciation of tin by reversed phase liquid chromatography with inductively coupled plasma mass spectrometric
    • Yang H.-J., Jiang S.-J., Yang Y.-J., Hwang C.-J. Speciation of tin by reversed phase liquid chromatography with inductively coupled plasma mass spectrometric. Anal. Chim. Acta. 312:1995;141-148.
    • (1995) Anal. Chim. Acta , vol.312 , pp. 141-148
    • Yang, H.-J.1    Jiang, S.-J.2    Yang, Y.-J.3    Hwang, C.-J.4
  • 16
    • 0034510755 scopus 로고    scopus 로고
    • Determination of cobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry
    • Baker S.A., Miller-Ihli N.J. Determination of cobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry. Spectrochim. Acta Part B. 55:2000;1823-1832.
    • (2000) Spectrochim. Acta Part B , vol.55 , pp. 1823-1832
    • Baker, S.A.1    Miller-Ihli, N.J.2
  • 17
    • 0344352507 scopus 로고    scopus 로고
    • Determination of cobalamins and cobinamides by microbore reversed-phase HPLC with spectrophotometric, ion-spray ionization MS and inductively coupled plasma MS detection
    • Chassaigne H., Łobiński R. Determination of cobalamins and cobinamides by microbore reversed-phase HPLC with spectrophotometric, ion-spray ionization MS and inductively coupled plasma MS detection. Anal. Chim. Acta. 359:1998;227-235.
    • (1998) Anal. Chim. Acta , vol.359 , pp. 227-235
    • Chassaigne, H.1    Łobiński, R.2
  • 18
    • 0032660919 scopus 로고    scopus 로고
    • Species-selective determination of cobalamin analogues by reversed-phase HPLC with ICP-MS detection
    • Makarov A., Szpunar J. Species-selective determination of cobalamin analogues by reversed-phase HPLC with ICP-MS detection. J. Anal. At. Spectrom. 14:1999;1323-1327.
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 1323-1327
    • Makarov, A.1    Szpunar, J.2
  • 19
    • 0032165054 scopus 로고    scopus 로고
    • Nebulizer diagnostics: Fundamental parameters, challenges, and techniques on the horizon
    • McLean J.A., Minnich M.G., Iacone L.A., Liu H., Montaser A. Nebulizer diagnostics: fundamental parameters, challenges, and techniques on the horizon. J. Anal. At. Spectrom. 13:1998;829-842.
    • (1998) J. Anal. At. Spectrom. , vol.13 , pp. 829-842
    • McLean, J.A.1    Minnich, M.G.2    Iacone, L.A.3    Liu, H.4    Montaser, A.5
  • 20
    • 0036009257 scopus 로고    scopus 로고
    • Influence of the spray chamber design for vapor-based liquid sample introduction at room temperature in ICP-AES
    • Todolí J.L., Mermet J.M. Influence of the spray chamber design for vapor-based liquid sample introduction at room temperature in ICP-AES. J. Anal. At. Spectrom. 17:2002;211-218.
    • (2002) J. Anal. At. Spectrom. , vol.17 , pp. 211-218
    • Todolí, J.L.1    Mermet, J.M.2
  • 21
    • 0036012727 scopus 로고    scopus 로고
    • Evaluation of new models for drop size distribution prediction of aerosols in atomic spectrometry: Pneumatic nebulizers
    • Gras L., Alvarez M.L., Canals A. Evaluation of new models for drop size distribution prediction of aerosols in atomic spectrometry: pneumatic nebulizers. J. Anal. At. Spectrom. 17:2002;524-529.
    • (2002) J. Anal. At. Spectrom. , vol.17 , pp. 524-529
    • Gras, L.1    Alvarez, M.L.2    Canals, A.3
  • 22
    • 58149320463 scopus 로고
    • Characterization of aerosols produced by pneumatic nebulizers for inductively coupled plasma sample introduction: Effect of liquid and gas flow rates on volume based drop size distributions
    • Olesik J.W., Bates L.C. Characterization of aerosols produced by pneumatic nebulizers for inductively coupled plasma sample introduction: effect of liquid and gas flow rates on volume based drop size distributions. Spectrochim. Acta Part B. 50:1995;285-303.
    • (1995) Spectrochim. Acta Part B , vol.50 , pp. 285-303
    • Olesik, J.W.1    Bates, L.C.2
  • 23
    • 0032632381 scopus 로고    scopus 로고
    • Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS
    • Baker S.A., Miller-Ihli N.J. Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS. Appl. Spectrosc. 53:1999;471-478.
    • (1999) Appl. Spectrosc. , vol.53 , pp. 471-478
    • Baker, S.A.1    Miller-Ihli, N.J.2
  • 24
    • 2942610653 scopus 로고    scopus 로고
    • Cobalamin speciation using reversed phase micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry
    • Yanes E.G., Miller-Ihli N.J. Cobalamin speciation using reversed phase micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry. Spectrochim. Acta Part B. 59:2004;891-899.
    • (2004) Spectrochim. Acta Part B , vol.59 , pp. 891-899
    • Yanes, E.G.1    Miller-Ihli, N.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.