Volumn 27, Issue 6 PART I, 2004, Pages 719-725

Intramural radiofrequency ablation: Effects of electrode temperature and length

Author keywords

Ablation; Arrhythmia; Electrophysiology

Indexed keywords

ARTICLE; CORRELATION ANALYSIS; ELECTRODE; ELECTROSURGERY; EPICARDIUM; GEOMETRY; HEART DISEASE; HEART INJURY; HEART MUSCLE; HEART VENTRICLE TACHYCARDIA; IMPEDANCE; RADIOFREQUENCY; STAINING; TEMPERATURE; TEMPERATURE SENSITIVITY; THORACOTOMY;

EID: 2942545741     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2004.00519.x     Document Type: Article
Times cited : (16)

References (22)
  • 1
    • 0026605085 scopus 로고
    • Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart disease
    • Klein LS, Shish H-T, Hackett K, et al. Radiofrequency catheter ablation of ventricular tachycardia in patients without structural heart disease. Circulation 1992; 85:1666-1674.
    • (1992) Circulation , vol.85 , pp. 1666-1674
    • Klein, L.S.1    Shish, H.-T.2    Hackett, K.3
  • 2
    • 0027308941 scopus 로고
    • Catheter ablation with radiofrequency current of ventricular tachycardia originating from the right ventricle
    • Aizawa Y, Chinushi M, Naitoh N, et al. Catheter ablation with radiofrequency current of ventricular tachycardia originating from the right ventricle. Am Heart J 1993; 125:1269-1275.
    • (1993) Am Heart J , vol.125 , pp. 1269-1275
    • Aizawa, Y.1    Chinushi, M.2    Naitoh, N.3
  • 3
    • 0026038827 scopus 로고
    • Radiofrequency catheter ablation for treatment of bundle branch reentrant ventricular tachycardia: Results and long-term follow-up
    • Cohen TJ, Chien WW, Lurie KG, et al. Radiofrequency catheter ablation for treatment of bundle branch reentrant ventricular tachycardia: Results and long-term follow-up. J Am Coll Cardiol 1991; 18:1767-1773.
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1767-1773
    • Cohen, T.J.1    Chien, W.W.2    Lurie, K.G.3
  • 4
    • 0028329881 scopus 로고
    • Catheter ablation of ventricular tachycardia occurring late after myocardial infarction: A point of view
    • D'Avila A, Nellens P, Andries E, et al. Catheter ablation of ventricular tachycardia occurring late after myocardial infarction: A point of view. PACE 1994; 17:532-541.
    • (1994) PACE , vol.17 , pp. 532-541
    • D'Avila, A.1    Nellens, P.2    Andries, E.3
  • 5
    • 0027396960 scopus 로고
    • A prospective randomized comparison of direct current and radiofrequency ablation of the atrioventricular junction
    • Morady F, Calkins H, Langberg JJ, et al. A prospective randomized comparison of direct current and radiofrequency ablation of the atrioventricular junction. J Am Coll Cardiol 1993; 21:102-109.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 102-109
    • Morady, F.1    Calkins, H.2    Langberg, J.J.3
  • 6
    • 9544220610 scopus 로고
    • Treatment of ventricular tachycardia by transcatheter radiofrequency ablation in patients with ischemic heart disease
    • Kim YH, Sosa-Suarez G, Trouton TG, et al. Treatment of ventricular tachycardia by transcatheter radiofrequency ablation in patients with ischemic heart disease. Circulation 1994; 89:1094-1102.
    • (1994) Circulation , vol.89 , pp. 1094-1102
    • Kim, Y.H.1    Sosa-Suarez, G.2    Trouton, T.G.3
  • 7
    • 0028126734 scopus 로고
    • Catheter ablation of ventricular tachycardia in 136 patients with coronary artery disease: Results and long-term follow-up
    • Gonska B-D, Cao K, Schaumann A, et al. Catheter ablation of ventricular tachycardia in 136 patients with coronary artery disease: Results and long-term follow-up. J Am Coll Cardiol 1994; 24:1506-1514.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 1506-1514
    • Gonska, B.-D.1    Cao, K.2    Schaumann, A.3
  • 8
    • 0033972402 scopus 로고    scopus 로고
    • Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation
    • Petersen HH, Chen X, Pietersen A, et al. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: An in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation. PACE 2000; 23:8-17.
    • (2000) PACE , vol.23 , pp. 8-17
    • Petersen, H.H.1    Chen, X.2    Pietersen, A.3
  • 9
    • 0031793610 scopus 로고    scopus 로고
    • Comparison of standard and irrigated radiofrequency ablation in the canine ventricle
    • Skrumeda LL, Mehra R. Comparison of standard and irrigated radiofrequency ablation in the canine ventricle. J Cardiovasc Electrophysiol 1998; 9:1196-1205.
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 1196-1205
    • Skrumeda, L.L.1    Mehra, R.2
  • 10
    • 0028240838 scopus 로고
    • Effects of radiofrequency catheter ablation on regional myocardial blood flow: Possible mechanism for late electrophysiological outcome
    • Nath S, Whayne JG, Kaul S, et al. Effects of radiofrequency catheter ablation on regional myocardial blood flow: Possible mechanism for late electrophysiological outcome. Circulation 1994; 89:2667-2672.
    • (1994) Circulation , vol.89 , pp. 2667-2672
    • Nath, S.1    Whayne, J.G.2    Kaul, S.3
  • 11
    • 0024363035 scopus 로고
    • The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro
    • Blouin LT, Marcus FI. The effect of electrode design on the efficiency of delivery of radiofrequency energy to cardiac tissue in vitro. PACE 1989; 12:136-143.
    • (1989) PACE , vol.12 , pp. 136-143
    • Blouin, L.T.1    Marcus, F.I.2
  • 12
    • 0029074563 scopus 로고
    • Temperature measurement as a determinant of tissue heating during radiofrequency catheter ablation: An examination of electrode thermistor positioning for measurement accuracy
    • McRury ID, Whayne JG, Haines DE. Temperature measurement as a determinant of tissue heating during radiofrequency catheter ablation: An examination of electrode thermistor positioning for measurement accuracy. J Cardiovasc Electrophysiol 1995; 6:268-278.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 268-278
    • McRury, I.D.1    Whayne, J.G.2    Haines, D.E.3
  • 13
    • 0025775063 scopus 로고
    • Assessment of effects of a radiofrequency energy field and thermistor location in an electrode catheter on the accuracy of temperature measurement
    • Blouin LT, Marcus FI, Lampe L. Assessment of effects of a radiofrequency energy field and thermistor location in an electrode catheter on the accuracy of temperature measurement. PACE 1991; 14:807-813.
    • (1991) PACE , vol.14 , pp. 807-813
    • Blouin, L.T.1    Marcus, F.I.2    Lampe, L.3
  • 14
    • 0024991053 scopus 로고
    • Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium
    • Haines DE, Verow AF. Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium. Circulation 1990; 82:1034-1038.
    • (1990) Circulation , vol.82 , pp. 1034-1038
    • Haines, D.E.1    Verow, A.F.2
  • 15
    • 0026453209 scopus 로고
    • Temperature monitoring during radiofrequency catheter ablation of accessory pathways
    • Langberg JJ, Calkins H, El-Atassi R, et al. Temperature monitoring during radiofrequency catheter ablation of accessory pathways. Circulation 1992; 86:1469-1474.
    • (1992) Circulation , vol.86 , pp. 1469-1474
    • Langberg, J.J.1    Calkins, H.2    El-Atassi, R.3
  • 16
    • 0027316390 scopus 로고
    • The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring
    • Haines DE. The biophysics of radiofrequency catheter ablation in the heart: The importance of temperature monitoring. PACE 1993; 16:586-591.
    • (1993) PACE , vol.16 , pp. 586-591
    • Haines, D.E.1
  • 17
    • 0027295050 scopus 로고
    • Temperature-guided radiofrequency catheter ablation with very large distal electrodes
    • Langberg JJ, Gallagher M, Strickberger AS, et al. Temperature-guided radiofrequency catheter ablation with very large distal electrodes. Circulation 1993; 88:245-249.
    • (1993) Circulation , vol.88 , pp. 245-249
    • Langberg, J.J.1    Gallagher, M.2    Strickberger, A.S.3
  • 18
    • 0026325244 scopus 로고
    • Determinants of lesion size during radiofrequency catheter ablation: The role of electrode-tissue contact pressure and duration of energy delivery
    • Haines D. Determinants of lesion size during radiofrequency catheter ablation: The role of electrode-tissue contact pressure and duration of energy delivery. J Cardiovasc Electrophysiol 1991; 2:509-515.
    • (1991) J Cardiovasc Electrophysiol , vol.2 , pp. 509-515
    • Haines, D.1
  • 19
    • 0024364286 scopus 로고
    • Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall
    • Haines DE, Watson DD. Tissue heating during radiofrequency catheter ablation: A thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall. PACE 1989; 12:962-976.
    • (1989) PACE , vol.12 , pp. 962-976
    • Haines, D.E.1    Watson, D.D.2
  • 20
    • 0027438063 scopus 로고
    • Cellular electrophysiological effects of hyperthermia on isolated guinea pig papillary muscle. Implications for catheter ablation
    • Nath S, Lynch C III, Whayne JG, et al. Cellular electrophysiological effects of hyperthermia on isolated guinea pig papillary muscle. Implications for catheter ablation. Circulation 1993; 88:1826-1831.
    • (1993) Circulation , vol.88 , pp. 1826-1831
    • Nath, S.1    Lynch III, C.2    Whayne, J.G.3
  • 21
    • 2942516843 scopus 로고
    • Does impedance monitoring during radiofrequency catheter ablation reduce the risk of impedance rise?
    • Hoffman E, Remp T, Gerth A, et al. Does impedance monitoring during radiofrequency catheter ablation reduce the risk of impedance rise? Circulation 1993; 88:1-165.
    • (1993) Circulation , vol.88 , pp. 1-165
    • Hoffman, E.1    Remp, T.2    Gerth, A.3
  • 22
    • 3242772146 scopus 로고    scopus 로고
    • Catheter intramural radiofrequency ablation creates deeper lesion than irrigated tip catheter ablation
    • In press
    • Thiagalingam A, Campbell C, Boyd A, et al. Catheter intramural radiofrequency ablation creates deeper lesion than irrigated tip catheter ablation. PACE 2004; (In press).
    • (2004) PACE
    • Thiagalingam, A.1    Campbell, C.2    Boyd, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.