메뉴 건너뛰기




Volumn 50, Issue 24, 2005, Pages 5799-5811

Towards an inline reconstruction architecture for micro-CT systems

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; DATA ACQUISITION; IMAGE RECONSTRUCTION; MATHEMATICAL MODELS; MEDICAL IMAGING; OPTICAL RESOLVING POWER;

EID: 29144499121     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/50/24/003     Document Type: Article
Times cited : (31)

References (23)
  • 2
    • 0026222976 scopus 로고
    • Use of transputers in 3-D positron emission tomography
    • Atkins M S, Murray D and Harrop R 1991 Use of transputers in 3-D positron emission tomography IEEE Trans. Med. Imaging 10 276-83
    • (1991) IEEE Trans. Med. Imaging , vol.10 , Issue.3 , pp. 276-283
    • Atkins, M.S.1    Murray, D.2    Harrop, R.3
  • 4
    • 3042786399 scopus 로고    scopus 로고
    • Distance-driven projection and backprojection in three dimensions
    • De Man B and Basu S 2004 Distance-driven projection and backprojection in three dimensions Phys. Med. Biol. 49 2463-75
    • (2004) Phys. Med. Biol. , vol.49 , Issue.11 , pp. 2463-2475
    • De Man, B.1    Basu, S.2
  • 7
    • 20744449792 scopus 로고    scopus 로고
    • The design and implementation of FFTW3
    • Frigo M and Johnson S G 2005 The design and implementation of FFTW3 Proc. IEEE 93 216-31
    • (2005) Proc. IEEE , vol.93 , Issue.2 , pp. 216-231
    • Frigo, M.1    Johnson, S.G.2
  • 8
  • 9
    • 0037036595 scopus 로고    scopus 로고
    • Analysis of an exact inversion algorithm for spiral cone-beam CT
    • Katsevich A 2002 Analysis of an exact inversion algorithm for spiral cone-beam CT Phys. Med. Biol. 47 2583-97
    • (2002) Phys. Med. Biol. , vol.47 , Issue.15 , pp. 2583-2597
    • Katsevich, A.1
  • 10
    • 3442891562 scopus 로고    scopus 로고
    • Exact and approximate algorithms for helical cone-beam CT
    • Kudo H, Rodet T, Noo F and Defrise M 2004 Exact and approximate algorithms for helical cone-beam CT Phys. Med. Biol. 49 2913-31
    • (2004) Phys. Med. Biol. , vol.49 , Issue.13 , pp. 2913-2931
    • Kudo, H.1    Rodet, T.2    Noo, F.3    Defrise, M.4
  • 11
    • 0032156791 scopus 로고    scopus 로고
    • Parallel image reconstruction on MIMD computers for three-dimensional cone-beam tomography
    • Laurent C, Peyrin F, Chassery J-M and Amiel M 1998 Parallel image reconstruction on MIMD computers for three-dimensional cone-beam tomography Parallel Comput. 24 1461-79
    • (1998) Parallel Comput. , vol.24 , Issue.9-10 , pp. 1461-1479
    • Laurent, C.1    Peyrin, F.2    Chassery, J.-M.3    Amiel, M.4
  • 12
    • 0029236473 scopus 로고
    • Lithography and the future of Moore's law
    • Moore G E 1995 Lithography and the future of Moore's law Proc. SPIE 2438 2-17
    • (1995) Proc. SPIE , vol.2438 , pp. 2-17
    • Moore, G.E.1
  • 13
    • 0035288499 scopus 로고    scopus 로고
    • A review of high-resolution x-ray computed tomography and other imaging modalities for small animal research
    • Paulus M J, Gleason S S, Easterly M E and Foltz C J 2001 A review of high-resolution x-ray computed tomography and other imaging modalities for small animal research Lab Anim. 30 36-45
    • (2001) Lab Anim. , vol.30 , pp. 36-45
    • Paulus, M.J.1    Gleason, S.S.2    Easterly, M.E.3    Foltz, C.J.4
  • 14
    • 0034088968 scopus 로고    scopus 로고
    • High resolution x-ray computed tomography: An emerging tool for small animal cancer research
    • Paulus M J, Gleasen S S, Kennel S J, Hunsicker P R and Johnson D K 2000 High resolution x-ray computed tomography: an emerging tool for small animal cancer research Neoplasia 2 62-70
    • (2000) Neoplasia , vol.2 , Issue.1-2 , pp. 62-70
    • Paulus, M.J.1    Gleasen, S.S.2    Kennel, S.J.3    Hunsicker, P.R.4    Johnson, D.K.5
  • 16
    • 4544330465 scopus 로고    scopus 로고
    • Micro-computed tomography-current status and developments
    • Ritman E L 2004 Micro-computed tomography-current status and developments Ann. Rev. Biomed. Eng. 6 185-208
    • (2004) Ann. Rev. Biomed. Eng. , vol.6 , Issue.1 , pp. 185-208
    • Ritman, E.L.1
  • 18
    • 0039842061 scopus 로고    scopus 로고
    • Fast algorithm for x-ray cone-beam microtomography
    • Shih A, Wang G and Cheng P C 2001 Fast algorithm for x-ray cone-beam microtomography Microsc. Microanal. 7 13-23
    • (2001) Microsc. Microanal. , vol.7 , pp. 13-23
    • Shih, A.1    Wang, G.2    Cheng, P.C.3
  • 19
    • 29144467471 scopus 로고    scopus 로고
    • - ref-separator -
    • The message passing interface standard (MPI): http://www-unix.mcs.anl. gov/mpi - ref-separator -
  • 21
    • 0020764170 scopus 로고
    • An inversion formula for cone-beam reconstruction
    • Tuy H 1983 An inversion formula for cone-beam reconstruction SIAM J. Appl. Math. 43 546-52
    • (1983) SIAM J. Appl. Math. , vol.43 , Issue.3 , pp. 546-552
    • Tuy, H.1
  • 22
    • 0035390579 scopus 로고    scopus 로고
    • Micro-CT scanners for biomedical applications: An overview
    • Wang G and Vannier M 2001 Micro-CT scanners for biomedical applications: an overview Adv. Imaging 16 18-27
    • (2001) Adv. Imaging , vol.16 , pp. 18-27
    • Wang, G.1    Vannier, M.2
  • 23
    • 29144516927 scopus 로고    scopus 로고
    • Near-interactive cone-beam computed tomography on commodity PC graphics hardware
    • Xu F and Mueller K 2004 Near-interactive cone-beam computed tomography on commodity PC graphics hardware IEEE Int. Symposium on Biomedical Imaging
    • (2004) IEEE Int. Symposium on Biomedical Imaging
    • Xu, F.1    Mueller, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.