메뉴 건너뛰기




Volumn 52, Issue 5 I, 2005, Pages 1329-1334

A hybrid approach to simulate X-ray imaging techniques, combining Monte Carlo and deterministic algorithms

Author keywords

Deterministic simulation; Dose calculation; Forced detection; Hybrid simulation; Monte Carlo method; Rayleigh and Compton scattering; X ray imaging

Indexed keywords

ALGORITHMS; COMPUTATIONAL METHODS; DOSIMETRY; MONTE CARLO METHODS; RAYLEIGH SCATTERING;

EID: 29144490757     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2005.858223     Document Type: Article
Times cited : (16)

References (17)
  • 1
    • 0032402834 scopus 로고    scopus 로고
    • Human body radiography simulations: Development of a virtual radiography environment
    • San Diego, CA: SPIE - The Int. Soc. Opt. Eng., Feb.
    • F. Inanc, J. N. Gray, T. Jensen, and J. Xu, "Human body radiography simulations: development of a virtual radiography environment," in Phys. Med. Imag.. San Diego, CA: SPIE - The Int. Soc. Opt. Eng., Feb. 1998, vol. 3336, pp. 830-837.
    • (1998) Phys. Med. Imag. , vol.3336 , pp. 830-837
    • Inanc, F.1    Gray, J.N.2    Jensen, T.3    Xu, J.4
  • 2
    • 0033624786 scopus 로고    scopus 로고
    • A software data generator for radiographic imaging investigations
    • D. Lazos, Z. Kolitsi, and N. Pallikarakis, "A software data generator for radiographic imaging investigations," IEEE Trans. Inf. Technol. Biomed., vol. 4, no. 1, pp. 76-79, 2000.
    • (2000) IEEE Trans. Inf. Technol. Biomed. , vol.4 , Issue.1 , pp. 76-79
    • Lazos, D.1    Kolitsi, Z.2    Pallikarakis, N.3
  • 4
    • 0031252019 scopus 로고    scopus 로고
    • Scattering simulations in radiography
    • F. Inanc and J. N. Gray, "Scattering simulations in radiography," Appl. Radiat, Isot., vol. 48, no. 10-12, pp. 1299-1305, 1997.
    • (1997) Appl. Radiat, Isot. , vol.48 , Issue.10-12 , pp. 1299-1305
    • Inanc, F.1    Gray, J.N.2
  • 5
    • 0036894954 scopus 로고    scopus 로고
    • Scattering and its role in radiography simulations
    • F. Inanc, "Scattering and its role in radiography simulations, " NDT&E Int., vol. 35, pp. 581-593, 2002.
    • (2002) NDT&E Int. , vol.35 , pp. 581-593
    • Inanc, F.1
  • 6
    • 0006397584 scopus 로고    scopus 로고
    • Simulation of scattering process in radiation techniques exploiting the theory of Markovian processes with random structure
    • D. O. Thompson and D. E. Chimenti, Eds. New York: Plenum
    • G.-R. Tillack, C. Bellon, V. M. Artemiev, and A. O. Naumov, "Simulation of scattering process in radiation techniques exploiting the theory of Markovian processes with random structure," in Review of Progress in Quantitative Nondestructive Evaluation, D. O. Thompson and D. E. Chimenti, Eds. New York: Plenum, 1997, vol. 16, pp. 309-316.
    • (1997) Review of Progress in Quantitative Nondestructive Evaluation , vol.16 , pp. 309-316
    • Tillack, G.-R.1    Bellon, C.2    Artemiev, V.M.3    Naumov, A.O.4
  • 9
    • 0043231255 scopus 로고    scopus 로고
    • ROSI - An object-oriented and parallel-computing Monte-Carlo simulation for X-ray imaging
    • J. Giersch, A. Weidemann, and G. Anton, "ROSI - an object-oriented and parallel-computing Monte-Carlo simulation for x-ray imaging," Nucl. Instrum. Methods Phys. Res. A, vol. 509, pp. 151-156, 2003.
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.509 , pp. 151-156
    • Giersch, J.1    Weidemann, A.2    Anton, G.3
  • 10
    • 0035251586 scopus 로고    scopus 로고
    • Parallel implementation of the integral transport equation-based radiography simulation code
    • F. Inanc, B. Vasiliu, and D. Turner, "Parallel implementation of the integral transport equation-based radiography simulation code," Nucl. Sci. Eng., vol. 137, pp. 173-182, 2001.
    • (2001) Nucl. Sci. Eng. , vol.137 , pp. 173-182
    • Inanc, F.1    Vasiliu, B.2    Turner, D.3
  • 11
    • 10444239392 scopus 로고    scopus 로고
    • A hybrid approach to simulate multiple photon scattering in X-ray imaging
    • N. Freud, J.-M. Létang, and D. Babot, "A hybrid approach to simulate multiple photon scattering in x-ray imaging," Nucl. Instrum. Methods Phys. Res. B, no. 227, pp. 551-558, 2005.
    • (2005) Nucl. Instrum. Methods Phys. Res. B , Issue.227 , pp. 551-558
    • Freud, N.1    Létang, J.-M.2    Babot, D.3
  • 12
    • 0019526041 scopus 로고
    • Analysis of SPECT including scatter and attenuation using sophisticated Monte Carlo modeling methods
    • J. W. Beck, R. J. Jaszczak, R. E. Coleman, C. F. Starmer, and L. W. Nolte, "Analysis of SPECT including scatter and attenuation using sophisticated Monte Carlo modeling methods," IEEE Trans. Nucl. Sci., vol. 29, no. 1, pp. 506-511, 1982.
    • (1982) IEEE Trans. Nucl. Sci. , vol.29 , Issue.1 , pp. 506-511
    • Beck, J.W.1    Jaszczak, R.J.2    Coleman, R.E.3    Starmer, C.F.4    Nolte, L.W.5
  • 13
    • 0005824598 scopus 로고    scopus 로고
    • ser. Medical Science Series. Bristol, U.K.: Instit. Phys. ch. 2
    • D. R. Haynor, Monte Carlo Calculations in Nuclear Medicine, ser. Medical Science Series. Bristol, U.K.: Instit. Phys., 1998, ch. 2, pp. 13-24.
    • (1998) Monte Carlo Calculations in Nuclear Medicine , pp. 13-24
    • Haynor, D.R.1
  • 14
    • 0004007304 scopus 로고    scopus 로고
    • EPDL97: The evaluated photon data library, '97 version
    • Lawrence Livermore Nat. Lab., September
    • D. E. Cullen, J. H. Hubbell, and L. Kissel, "EPDL97: the Evaluated Photon Data Library, '97 Version," Lawrence Livermore Nat. Lab., Tech. Rep. UCRL-ID-50400, vol. 6, September 1997.
    • (1997) Tech. Rep. UCRL-ID-50400 , vol.6
    • Cullen, D.E.1    Hubbell, J.H.2    Kissel, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.