-
1
-
-
18544367203
-
A pixel detector with large dynamic range for high photon counting rates
-
J. F. Bérar, L. Blanquart, N. Boudet, P. Breugnon, B. Caillot, J. C. Clemens, P. Delpierre, I. Koudobine, C. Mouget, P. Potheau, and I. Valin, "A pixel detector with large dynamic range for high photon counting rates," J. App. Crystallogr., vol. 35, pp. 471-476, 2002.
-
(2002)
J. App. Crystallogr.
, vol.35
, pp. 471-476
-
-
Bérar, J.F.1
Blanquart, L.2
Boudet, N.3
Breugnon, P.4
Caillot, B.5
Clemens, J.C.6
Delpierre, P.7
Koudobine, I.8
Mouget, C.9
Potheau, P.10
Valin, I.11
-
2
-
-
0043013190
-
Evaluation of Medipix-1 in X-ray scattering and X-ray diffraction applications
-
C. Ponchut and F. Zontone, "Evaluation of Medipix-1 in X-ray scattering and X-ray diffraction applications," Nucl. Instrum. Methods Phys. Res. A, vol. 510, pp. 29-34, 2003.
-
(2003)
Nucl. Instrum. Methods Phys. Res. A
, vol.510
, pp. 29-34
-
-
Ponchut, C.1
Zontone, F.2
-
3
-
-
0042011327
-
Continuous sample rotation data collection for protein crystallography with the PILATUS detector
-
C. Broennimann, E. F. Eikenberry, R. Horisberger, G. Huelsen, B. Schmitt, C. Schulze-Briese, and T. Tomizaki, "Continuous sample rotation data collection for protein crystallography with the PILATUS detector," Nucl. Instrum. Methods Phys. Res. A, vol. 510, pp. 24-28, 2003.
-
(2003)
Nucl. Instrum. Methods Phys. Res. A
, vol.510
, pp. 24-28
-
-
Broennimann, C.1
Eikenberry, E.F.2
Horisberger, R.3
Huelsen, G.4
Schmitt, B.5
Schulze-Briese, C.6
Tomizaki, T.7
-
4
-
-
0043231249
-
Area detectors in structural biology
-
J. R. Plaisier, R. I. Koning, H. K. Koerten, A. M. V. Roon, E. A. J. Thomassen, M. E. Kuil, J. Hendrix, C. Broennimann, N. S. Pannu, and J. P. Abrahams, "Area detectors in structural biology," Nucl. Instrum. Methods Phys. Res. A, vol. 509, pp. 274-282, 2003.
-
(2003)
Nucl. Instrum. Methods Phys. Res. A
, vol.509
, pp. 274-282
-
-
Plaisier, J.R.1
Koning, R.I.2
Koerten, H.K.3
Roon, A.M.V.4
Thomassen, E.A.J.5
Kuil, M.E.6
Hendrix, J.7
Broennimann, C.8
Pannu, N.S.9
Abrahams, J.P.10
-
5
-
-
0036815755
-
Medipix2: A 64-k pixel readout chip with 55 μm square elements working in single photon counting mode
-
Oct.
-
X. Llopart, M. Campbell, R. Dinapoli, D. SanSegundo, and E. Pernigotti, "Medipix2: A 64-k pixel readout chip with 55 μm square elements working in single photon counting mode," IEEE Trans. Nucl. Sci., vol. 49, no. 5, pp. 2279-2283, Oct. 2002.
-
(2002)
IEEE Trans. Nucl. Sci.
, vol.49
, Issue.5
, pp. 2279-2283
-
-
Llopart, X.1
Campbell, M.2
Dinapoli, R.3
Sansegundo, D.4
Pernigotti, E.5
-
6
-
-
0037150212
-
Evaluation of a photon-counting hybrid pixel detector array with a synchrotron X-ray source
-
C. Ponchut, J. L. Visschers, A. Fornaini, H. Graafsma, M. Maiorino, G. Mettivier, and D. Calvet, "Evaluation of a photon-counting hybrid pixel detector array with a synchrotron X-ray source," Nucl. Instrum. Methods Phys. Res. A, vol. 484, pp. 396-406, 2002.
-
(2002)
Nucl. Instrum. Methods Phys. Res. A
, vol.484
, pp. 396-406
-
-
Ponchut, C.1
Visschers, J.L.2
Fornaini, A.3
Graafsma, H.4
Maiorino, M.5
Mettivier, G.6
Calvet, D.7
-
7
-
-
0026837927
-
A simple method for determining the modulation transfer function in digital radiography
-
Mar.
-
H. Fujita, D.-Y. Tsai, T. Itoh, K. Doi, J. Morishita, K. Ueda, and A. Ohtsuka, "A simple method for determining the modulation transfer function in digital radiography," IEEE Trans. Med. Imag., vol. 11, no. 1, pp. 34-39, Mar. 1992.
-
(1992)
IEEE Trans. Med. Imag.
, vol.11
, Issue.1
, pp. 34-39
-
-
Fujita, H.1
Tsai, D.-Y.2
Itoh, T.3
Doi, K.4
Morishita, J.5
Ueda, K.6
Ohtsuka, A.7
-
8
-
-
20444444370
-
First DQE measurement of 500 μm silicon hybrid pixel sensor with photon counting readout for X-ray medical imaging
-
B. Surre, M. Caria, J. Chaput, T. Hassoun, F. Laverroux, and L. Sarry, "First DQE measurement of 500 μm silicon hybrid pixel sensor with photon counting readout for X-ray medical imaging," Nucl. Instrum. Methods Phys. Res. A, vol. 546, pp. 24-27, 2005.
-
(2005)
Nucl. Instrum. Methods Phys. Res. A
, vol.546
, pp. 24-27
-
-
Surre, B.1
Caria, M.2
Chaput, J.3
Hassoun, T.4
Laverroux, F.5
Sarry, L.6
-
9
-
-
0034867061
-
Measurement of the noise power spectrum in digital x-ray detectors
-
R. Aufrichtig, Y. Su, Y. Cheng, and P. R. Granfors, "Measurement of the noise power spectrum in digital x-ray detectors," Proc. SPIE-Int. Soc. Opt. Eng., vol. 4320, pp. 362-372, 2001.
-
(2001)
Proc. SPIE-Int. Soc. Opt. Eng.
, vol.4320
, pp. 362-372
-
-
Aufrichtig, R.1
Su, Y.2
Cheng, Y.3
Granfors, P.R.4
-
10
-
-
0032402775
-
Image quality of scintillator based X-ray electronic imagers
-
J. P. Moy, "Image quality of scintillator based X-ray electronic imagers," Proc. SPIE-Int. Soc. Opt. Eng., vol. 3336, pp. 187-194, 1998.
-
(1998)
Proc. SPIE-int. Soc. Opt. Eng.
, vol.3336
, pp. 187-194
-
-
Moy, J.P.1
-
11
-
-
0017453251
-
Evaluation of area photon detectors by a method based on detective quantum efficiency (DQE)
-
Feb.
-
S. M. Gruner, J. R. Milch, and G. T. Reynolds, "Evaluation of area photon detectors by a method based on detective quantum efficiency (DQE)," IEEE Trans. Nucl. Sci., vol. 25, no. 1, pp. 562-565, Feb. 1978.
-
(1978)
IEEE Trans. Nucl. Sci.
, vol.25
, Issue.1
, pp. 562-565
-
-
Gruner, S.M.1
Milch, J.R.2
Reynolds, G.T.3
-
12
-
-
0142089322
-
2 amorphous silicon flatpanel detector designed for angiographic and R&F imaging applications
-
2 amorphous silicon flatpanel detector designed for angiographic and R&F imaging applications," Med. Phys., vol. 30, pp. 2715-2726, 2003.
-
(2003)
Med. Phys.
, vol.30
, pp. 2715-2726
-
-
Granfors, P.R.1
Aufrichtig, R.2
Possin, G.E.3
Gianbattista, B.W.4
Huang, Z.S.5
Liu, J.6
Ma, B.7
|