메뉴 건너뛰기




Volumn 24, Issue 4, 2005, Pages 176-185

Intraoperative EEG monitoring

Author keywords

BIS; EEG monitoring; PSA

Indexed keywords

ALGORITHM; DATA ANALYSIS; DECISION MAKING; ELECTROENCEPHALOGRAM; HUMAN; MEDICAL LITERATURE; MEDICAL PRACTICE; PEROPERATIVE CARE; PRIORITY JOURNAL; REVIEW; SIGNAL TRANSDUCTION;

EID: 28844464322     PISSN: 02770326     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.sane.2005.10.007     Document Type: Article
Times cited : (8)

References (71)
  • 1
    • 0016719282 scopus 로고
    • [Presentation of equipment: The monitor of cerebral function.]
    • M. Dubois [Presentation of equipment the monitor of cerebral function.] Ann Anesthesiol Fr 16 1975 519 528
    • (1975) Ann Anesthesiol Fr , vol.16 , pp. 519-528
    • Dubois, M.1
  • 2
    • 0018755729 scopus 로고
    • Development of the CFM: The Cerebral Function Analysing Monitor (CFAM)
    • D.E. Maynard Development of the CFM the Cerebral Function Analysing Monitor (CFAM) Ann Anesthesiol Fr 20 1979 253 255
    • (1979) Ann Anesthesiol Fr , vol.20 , pp. 253-255
    • Maynard, D.E.1
  • 3
    • 0021740598 scopus 로고
    • The anesthesia and brain monitor (ABM). Concept and performance
    • B. Kay The anesthesia and brain monitor (ABM). Concept and performance Acta Anaesthesiol Belg 35 suppl 1984 167 174
    • (1984) Acta Anaesthesiol Belg , vol.35 , Issue.SUPPL. , pp. 167-174
    • Kay, B.1
  • 4
    • 0018158128 scopus 로고
    • The EEMG: A practical index of cortical activity and muscular relaxation
    • M.H. Harmel, F.F. Klein, D.A. Davis The EEMG a practical index of cortical activity and muscular relaxation Acta Anaesthesiol Scand Suppl 70 1978 97 102
    • (1978) Acta Anaesthesiol Scand Suppl , vol.70 , pp. 97-102
    • Harmel, M.H.1    Klein, F.F.2    Davis, D.A.3
  • 5
    • 0038298284 scopus 로고    scopus 로고
    • A preliminary evaluation of a new derived EEG index monitor in anesthetized patients
    • K. Willmann, S. Springman, D. Rusy A preliminary evaluation of a new derived EEG index monitor in anesthetized patients J Clin Monit Comput 17 2002 345 350
    • (2002) J Clin Monit Comput , vol.17 , pp. 345-350
    • Willmann, K.1    Springman, S.2    Rusy, D.3
  • 6
    • 1842714959 scopus 로고    scopus 로고
    • The Narcotrend Index: Classification algorithm, correlation with propofol effect-site concentrations, and comparison with spectral parameters
    • A. Schultz, U. Grouven, F.A. Beger The Narcotrend Index classification algorithm, correlation with propofol effect-site concentrations, and comparison with spectral parameters Biomed Tech 49 2004 38 42
    • (2004) Biomed Tech , vol.49 , pp. 38-42
    • Schultz, A.1    Grouven, U.2    Beger, F.A.3
  • 7
    • 0023796733 scopus 로고
    • Neurological monitoring during anaesthesia and surgery
    • W.J. McMeniman, G.J. Purcell Neurological monitoring during anaesthesia and surgery Anaesth Intens Care 16 1988 358 367
    • (1988) Anaesth Intens Care , vol.16 , pp. 358-367
    • McMeniman, W.J.1    Purcell, G.J.2
  • 8
    • 0033003007 scopus 로고    scopus 로고
    • Bispectral index (BIS) monitoring during propofol-induced sedation and anaesthesia
    • Harbhej Singh Bispectral index (BIS) monitoring during propofol-induced sedation and anaesthesia Eur J Anaesthesiol 16 1999 31 36
    • (1999) Eur J Anaesthesiol , vol.16 , pp. 31-36
    • Harbhej, S.1
  • 9
    • 3042781777 scopus 로고    scopus 로고
    • Monitoring depth of anaesthesia: Is it worth the effort?
    • V. Bonnhomme, P. Hans Monitoring depth of anaesthesia is it worth the effort? Eur J Anaesthesiol 21 2004 423 428
    • (2004) Eur J Anaesthesiol , vol.21 , pp. 423-428
    • Bonnhomme, V.1    Hans, P.2
  • 10
    • 0030963250 scopus 로고    scopus 로고
    • A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect
    • P.S. Sebel, E. Lang, I.J. Rampil A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect Anesth Analg 84 1997 891 899
    • (1997) Anesth Analg , vol.84 , pp. 891-899
    • Sebel, P.S.1    Lang, E.2    Rampil, I.J.3
  • 11
    • 0031955145 scopus 로고    scopus 로고
    • Clinical utility of EEG parameters to predict loss of consciousness and response to skin incision during total intravenous anaesthesia
    • S. Schraag, U. Mohl, U. Bothner Clinical utility of EEG parameters to predict loss of consciousness and response to skin incision during total intravenous anaesthesia Anaesthesia 53 1998 320 325
    • (1998) Anaesthesia , vol.53 , pp. 320-325
    • Schraag, S.1    Mohl, U.2    Bothner, U.3
  • 12
    • 0022253402 scopus 로고
    • Comparison of EEG monitoring techniques: An evaluation during cardiac surgery
    • A.P. Glaria, A. Murray Comparison of EEG monitoring techniques an evaluation during cardiac surgery Electroencephalogr Clin Neurophysiol 61 1985 323 330
    • (1985) Electroencephalogr Clin Neurophysiol , vol.61 , pp. 323-330
    • Glaria, A.P.1    Murray, A.2
  • 13
    • 0034010890 scopus 로고    scopus 로고
    • Bispectral index increases and decreases are not always signs of inadequate anesthesia
    • B. Guignard, M. Chauvin Bispectral index increases and decreases are not always signs of inadequate anesthesia Anesthesiology 92 2000 903
    • (2000) Anesthesiology , vol.92 , pp. 903
    • Guignard, B.1    Chauvin, M.2
  • 14
    • 0028935194 scopus 로고
    • Prediction of movement using bispectral electroencephalographic analysis during propofol/alfentanil or isoflurane/alfentanil anesthesia
    • J.M. Vernon, E. Lang, P.S. Sebel Prediction of movement using bispectral electroencephalographic analysis during propofol/alfentanil or isoflurane/alfentanil anesthesia Anesth Analg 80 1995 780 785
    • (1995) Anesth Analg , vol.80 , pp. 780-785
    • Vernon, J.M.1    Lang, E.2    Sebel, P.S.3
  • 15
    • 0031657514 scopus 로고    scopus 로고
    • A primer for EEG signal processing in anesthesia
    • I.J. Rampil A primer for EEG signal processing in anesthesia Anesthesiology 89 1998 980 1002
    • (1998) Anesthesiology , vol.89 , pp. 980-1002
    • Rampil, I.J.1
  • 16
    • 0036300626 scopus 로고    scopus 로고
    • Patient state index: Titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia
    • D.R. Drover, H.J. Lemmens, E.T. Pierce Patient state index titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia Anesthesiology 97 2002 82 89
    • (2002) Anesthesiology , vol.97 , pp. 82-89
    • Drover, D.R.1    Lemmens, H.J.2    Pierce, E.T.3
  • 17
    • 23044529146 scopus 로고    scopus 로고
    • Should we measure depth of anesthesia
    • M. Dershwitz Should we measure depth of anesthesia Sem Anesth Perioper Med Pain 20 2001 246 256
    • (2001) Sem Anesth Perioper Med Pain , vol.20 , pp. 246-256
    • Dershwitz, M.1
  • 18
    • 28844475671 scopus 로고    scopus 로고
    • JACHO Sentinel Alert Number 32
    • Joint Commission on Accreditation of Healthcare Organizations. Awareness under anesthesia. JACHO Sentinel Alert Number 32
    • Awareness under Anesthesia
  • 20
    • 0035190820 scopus 로고    scopus 로고
    • Comparison of changes in electroencephalographic measures during induction of general anaesthesia: Influence of the gamma frequency band and electromyogram signal
    • J.W. Sleigh, D.A. Steyn-Ross, M.L. Steyn-Ross Comparison of changes in electroencephalographic measures during induction of general anaesthesia influence of the gamma frequency band and electromyogram signal Br J Anaesth 86 2001 50 58
    • (2001) Br J Anaesth , vol.86 , pp. 50-58
    • Sleigh, J.W.1    Steyn-Ross, D.A.2    Steyn-Ross, M.L.3
  • 21
    • 9744235773 scopus 로고    scopus 로고
    • Awareness and the EEG power spectrum: Analysis of frequencies
    • O. Dressler, G. Schneider, G. Stockmanns Awareness and the EEG power spectrum analysis of frequencies Br J Anaesth 93 2004 806 809
    • (2004) Br J Anaesth , vol.93 , pp. 806-809
    • Dressler, O.1    Schneider, G.2    Stockmanns, G.3
  • 22
    • 20144364884 scopus 로고    scopus 로고
    • Cognitive avionics and watching spaceflight crews think: Generation-after-next research tools in functional neuroimaging
    • R.J. Genik 2nd, C.C. Green, F.X. Graydon Cognitive avionics and watching spaceflight crews think generation-after-next research tools in functional neuroimaging Aviat Space Environ Med 76 suppl 6 2005 B208 B212
    • (2005) Aviat Space Environ Med , vol.76 , Issue.6 SUPPL.
    • Genik II, R.J.1    Green, C.C.2    Graydon, F.X.3
  • 23
    • 0028110368 scopus 로고
    • The electroencephalogram does not predict depth of isoflurane anesthesia
    • R.C. Dwyer, I.J. Rampil, E.N. Eger The electroencephalogram does not predict depth of isoflurane anesthesia Anesthesiology 81 1994 403 409
    • (1994) Anesthesiology , vol.81 , pp. 403-409
    • Dwyer, R.C.1    Rampil, I.J.2    Eger, E.N.3
  • 24
    • 0031934912 scopus 로고    scopus 로고
    • Electroencephalographic derivatives as a tool for predicting depth of sedation and anesthesia induced by sevoflurane
    • T. Katoh, A. Suzuki, T. Ikeda Electroencephalographic derivatives as a tool for predicting depth of sedation and anesthesia induced by sevoflurane Anesthesiology 88 1998 642 650
    • (1998) Anesthesiology , vol.88 , pp. 642-650
    • Katoh, T.1    Suzuki, A.2    Ikeda, T.3
  • 25
    • 0033970358 scopus 로고    scopus 로고
    • Influence of age on hypnotic requirement, Bispectral Index, and 95% spectral edge frequency associated with sedation induced by sevoflurane
    • T. Katoh, H. Bito, S. Sato Influence of age on hypnotic requirement, Bispectral Index, and 95% spectral edge frequency associated with sedation induced by sevoflurane Anesthesiology 92 2000 55 66
    • (2000) Anesthesiology , vol.92 , pp. 55-66
    • Katoh, T.1    Bito, H.2    Sato, S.3
  • 27
    • 0031876291 scopus 로고    scopus 로고
    • Quantitative EEG correlations with brain glucose metabolic rate during anesthesia in volunteers
    • M.T. Alkire Quantitative EEG correlations with brain glucose metabolic rate during anesthesia in volunteers Anesthesiology 89 1998 323 333
    • (1998) Anesthesiology , vol.89 , pp. 323-333
    • Alkire, M.T.1
  • 28
    • 0016616321 scopus 로고
    • Cerebral protection by anaesthetics during ischaemia
    • J.D. Michenfelder, J.D. Milde Cerebral protection by anaesthetics during ischaemia Resuscitation 4 1975 219
    • (1975) Resuscitation , vol.4 , pp. 219
    • Michenfelder, J.D.1    Milde, J.D.2
  • 29
    • 10944222205 scopus 로고    scopus 로고
    • Anesthetic management and one-year mortality after noncardiac surgery
    • T.G. Monk, V. Saini, B.C. Weldon Anesthetic management and one-year mortality after noncardiac surgery Anesth Analg 100 2005 4 10
    • (2005) Anesth Analg , vol.100 , pp. 4-10
    • Monk, T.G.1    Saini, V.2    Weldon, B.C.3
  • 30
    • 10344244507 scopus 로고    scopus 로고
    • Emergency EEG and continuous EEG monitoring in acute ischemic stroke
    • K.G. Jordan Emergency EEG and continuous EEG monitoring in acute ischemic stroke J Clin Neurophysiol 21 2004 341 352
    • (2004) J Clin Neurophysiol , vol.21 , pp. 341-352
    • Jordan, K.G.1
  • 31
    • 0018956806 scopus 로고
    • Relationship of intraoperative EEG monitoring and stump pressure measurements during carotid endarterectomy
    • D.C. Brewster, P.J. O'Hara, R.C. Darling Relationship of intraoperative EEG monitoring and stump pressure measurements during carotid endarterectomy Circulation 62 1980 I4 I7
    • (1980) Circulation , vol.62
    • Brewster, D.C.1    O'Hara, P.J.2    Darling, R.C.3
  • 32
    • 0026742766 scopus 로고
    • Computerized electroencephalographic monitoring and selective shunting: Influence on intraoperative administration of phenylephrine and myocardial infarction after general anesthesia for carotid endarterectomy
    • P.A. Modica, R. Tempelhoff, K.M. Rich Computerized electroencephalographic monitoring and selective shunting influence on intraoperative administration of phenylephrine and myocardial infarction after general anesthesia for carotid endarterectomy Neurosurgery 30 1992 842 846
    • (1992) Neurosurgery , vol.30 , pp. 842-846
    • Modica, P.A.1    Tempelhoff, R.2    Rich, K.M.3
  • 33
    • 0020634366 scopus 로고
    • Computerized electroencephalogram monitoring and carotid artery shunting
    • I. Rampil, J.W. Correll, S.H. Rosenbaum Computerized electroencephalogram monitoring and carotid artery shunting Neurosurgery 13 1983 276
    • (1983) Neurosurgery , vol.13 , pp. 276
    • Rampil, I.1    Correll, J.W.2    Rosenbaum, S.H.3
  • 34
    • 0036894508 scopus 로고    scopus 로고
    • A comparison of patient state index and bispectral index values during the perioperative period
    • X. Chen, J. Tang, P.F. White A comparison of patient state index and bispectral index values during the perioperative period Anesth Analg 95 2002 1669 1674
    • (2002) Anesth Analg , vol.95 , pp. 1669-1674
    • Chen, X.1    Tang, J.2    White, P.F.3
  • 35
    • 6444233480 scopus 로고    scopus 로고
    • Is the patient state analyzer with the PSArray2 a cost-effective alternative to the bispectral index monitor during the perioperative period?
    • P.F. White, J. Tang, H. Ma Is the patient state analyzer with the PSArray2 a cost-effective alternative to the bispectral index monitor during the perioperative period? Anesth Analg 99 2004 1429 1435
    • (2004) Anesth Analg , vol.99 , pp. 1429-1435
    • White, P.F.1    Tang, J.2    Ma, H.3
  • 36
    • 0030664906 scopus 로고    scopus 로고
    • Temporary occlusion of the middle cerebral artery in intracranial aneurysm surgery: Time limitation and advantage of brain protection
    • S.D. Lavine, L.S. Maseri, M.L. Levy Temporary occlusion of the middle cerebral artery in intracranial aneurysm surgery time limitation and advantage of brain protection J Neurosurg 87 1997 817 824
    • (1997) J Neurosurg , vol.87 , pp. 817-824
    • Lavine, S.D.1    Maseri, L.S.2    Levy, M.L.3
  • 37
    • 0242474260 scopus 로고    scopus 로고
    • A marked decrease in bispectral index with elevation of suppression ratio by cervical haematoma reducing cerebral perfusion pressure
    • N. Umegaki, K. Hirota, M. Kitayama A marked decrease in bispectral index with elevation of suppression ratio by cervical haematoma reducing cerebral perfusion pressure J Clin Neurosci 10 2003 694 696
    • (2003) J Clin Neurosci , vol.10 , pp. 694-696
    • Umegaki, N.1    Hirota, K.2    Kitayama, M.3
  • 38
    • 0022360315 scopus 로고
    • The power spectrum analyser as an indicator of cerebral ischaemia during carotid endarterectomy
    • M.A. Ashburn, L.B. Mitchell, D.F. Dean The power spectrum analyser as an indicator of cerebral ischaemia during carotid endarterectomy Anaesth Intens Care 13 1985 387 391
    • (1985) Anaesth Intens Care , vol.13 , pp. 387-391
    • Ashburn, M.A.1    Mitchell, L.B.2    Dean, D.F.3
  • 39
    • 0024562838 scopus 로고
    • Selective shunting during carotid endarterectomy based on two-channel computerized electroencephalographic/compressed spectral array analysis
    • R. Tempelhoff, P.A. Modica, R.L. Grubb Jr Selective shunting during carotid endarterectomy based on two-channel computerized electroencephalographic/compressed spectral array analysis Neurosurgery 24 1989 339 344
    • (1989) Neurosurgery , vol.24 , pp. 339-344
    • Tempelhoff, R.1    Modica, P.A.2    Grubb Jr., R.L.3
  • 40
    • 0024351543 scopus 로고
    • Balloon test occlusion of the internal carotid artery with monitoring of compressed spectral arrays (CSAs) of electroencephalogram
    • T. Morioka, T. Matsushima, K. Fujii Balloon test occlusion of the internal carotid artery with monitoring of compressed spectral arrays (CSAs) of electroencephalogram Acta Neurochir (Wien) 101 1989 29 34
    • (1989) Acta Neurochir (Wien) , vol.101 , pp. 29-34
    • Morioka, T.1    Matsushima, T.2    Fujii, K.3
  • 41
    • 5744253296 scopus 로고    scopus 로고
    • Fatal ischemia stroke in a patient with an asymptomatic carotid artery occlusion after lumbar spine surgery: A case report
    • L.C. Wang, J.T. Liou, F.C. Liu Fatal ischemia stroke in a patient with an asymptomatic carotid artery occlusion after lumbar spine surgery a case report Acta Anaesthesiol Taiwan 42 2004 179 182
    • (2004) Acta Anaesthesiol Taiwan , vol.42 , pp. 179-182
    • Wang, L.C.1    Liou, J.T.2    Liu, F.C.3
  • 42
    • 2542562742 scopus 로고    scopus 로고
    • Bispectral index monitoring to prevent awareness during anaesthesia: The B-Aware randomised controlled trial
    • P. Myles, K. Leslie, J. McNeil Bispectral index monitoring to prevent awareness during anaesthesia the B-Aware randomised controlled trial Lancet 363 2004 1757 1763
    • (2004) Lancet , vol.363 , pp. 1757-1763
    • Myles, P.1    Leslie, K.2    McNeil, J.3
  • 43
    • 10744225339 scopus 로고    scopus 로고
    • The Patient State Index as an indicator of the level of hypnosis under general anaesthesia
    • L.S. Prichep, L.D. Gugino, E.R. John The Patient State Index as an indicator of the level of hypnosis under general anaesthesia Br J Anaesth 92 2004 393 399
    • (2004) Br J Anaesth , vol.92 , pp. 393-399
    • Prichep, L.S.1    Gugino, L.D.2    John, E.R.3
  • 44
    • 1942468900 scopus 로고    scopus 로고
    • Comparative evaluation of Narcotrend, Bispectral Index, and classical electroencephalographic variables during induction, maintenance, and emergence of a propofol/remifentanil anesthesia
    • G.N. Schmidt, P. Bischoff, T. Standl Comparative evaluation of Narcotrend, Bispectral Index, and classical electroencephalographic variables during induction, maintenance, and emergence of a propofol/remifentanil anesthesia Anesth Analg 98 2004 1346 1353
    • (2004) Anesth Analg , vol.98 , pp. 1346-1353
    • Schmidt, G.N.1    Bischoff, P.2    Standl, T.3
  • 45
    • 1842592081 scopus 로고    scopus 로고
    • Bispectral electroencephalographic analysis of head-injured patients in the emergency department
    • E. Haug, J. Miner, M. Dannehy Bispectral electroencephalographic analysis of head-injured patients in the emergency department Acad Emerg Med 11 2004 349 352
    • (2004) Acad Emerg Med , vol.11 , pp. 349-352
    • Haug, E.1    Miner, J.2    Dannehy, M.3
  • 46
    • 0242467596 scopus 로고    scopus 로고
    • Decreased bispectral index as an indicator of syncope before hypotension and bradycardia in two patients with needle phobia
    • N.N. Win, H. Kohase, T. Miyamoto Decreased bispectral index as an indicator of syncope before hypotension and bradycardia in two patients with needle phobia Br J Anaesth 91 2003 749 752
    • (2003) Br J Anaesth , vol.91 , pp. 749-752
    • Win, N.N.1    Kohase, H.2    Miyamoto, T.3
  • 47
    • 10944273953 scopus 로고    scopus 로고
    • The detection of cerebral hypoperfusion with Bispectral Index monitoring during general anesthesia
    • Monden, Yoko, K. Ohtake, T. Sakabe The detection of cerebral hypoperfusion with Bispectral Index monitoring during general anesthesia Anesth Analg 100 2005 158 161
    • (2005) Anesth Analg , vol.100 , pp. 158-161
    • Monden1    Yoko2    Ohtake, K.3    Sakabe, T.4
  • 48
    • 2942543376 scopus 로고    scopus 로고
    • The use of bispectral index during a cardiopulmonary arrest: A potential predictor of cerebral perfusion
    • N. Azim, C.Y. Wang The use of bispectral index during a cardiopulmonary arrest a potential predictor of cerebral perfusion Anaesthesia 59 2004 610 612
    • (2004) Anaesthesia , vol.59 , pp. 610-612
    • Azim, N.1    Wang, C.Y.2
  • 49
    • 23144433260 scopus 로고    scopus 로고
    • Use of the bispectral index during the early postresuscitative phase after out-of-hospital cardiac arrest
    • S. Shibata, T. Imota, S. Shigeomi Use of the bispectral index during the early postresuscitative phase after out-of-hospital cardiac arrest J Anesth 19 2005 243 246
    • (2005) J Anesth , vol.19 , pp. 243-246
    • Shibata, S.1    Imota, T.2    Shigeomi, S.3
  • 50
    • 0642274955 scopus 로고    scopus 로고
    • EEG bispectral index during carotid endarterectomy
    • A.A. el-Dawlatly EEG bispectral index during carotid endarterectomy Middle East J Anesthesiol 17 2003 287 293
    • (2003) Middle East J Anesthesiol , vol.17 , pp. 287-293
    • El-Dawlatly, A.A.1
  • 51
    • 0035528833 scopus 로고    scopus 로고
    • [BIS monitoring may allow the detection of severe cerebral ischemia.]
    • S. Merat, J.P. Levecque, Y. Le Gulluche [BIS monitoring may allow the detection of severe cerebral ischemia.] Can J Anaesth 48 2001 1066 1069
    • (2001) Can J Anaesth , vol.48 , pp. 1066-1069
    • Merat, S.1    Levecque, J.P.2    Le Gulluche, Y.3
  • 52
    • 19944384934 scopus 로고    scopus 로고
    • Bispectral index monitoring may not reliably indicate cerebral ischaemia during awake carotid endarterectomy
    • A. Deogaonkar, R. Vivar, R.E. Bullock Bispectral index monitoring may not reliably indicate cerebral ischaemia during awake carotid endarterectomy Br J Anaesth 94 2005 800 804
    • (2005) Br J Anaesth , vol.94 , pp. 800-804
    • Deogaonkar, A.1    Vivar, R.2    Bullock, R.E.3
  • 53
    • 1342346199 scopus 로고    scopus 로고
    • Anaesthesia for carotid endarterectomy: Comparison of hypnotic- and opioid-based techniques
    • G. Godet, M. Reina, M. Raux Anaesthesia for carotid endarterectomy comparison of hypnotic- and opioid-based techniques Br J Anaesth 92 2004 329 334
    • (2004) Br J Anaesth , vol.92 , pp. 329-334
    • Godet, G.1    Reina, M.2    Raux, M.3
  • 54
    • 20744434829 scopus 로고    scopus 로고
    • Bilateral bispectral index monitoring during suppression of unilateral hemispheric function
    • H. Heller, R. Hatami, P. Mullin Bilateral bispectral index monitoring during suppression of unilateral hemispheric function Anesth Analg 101 2005 235 241
    • (2005) Anesth Analg , vol.101 , pp. 235-241
    • Heller, H.1    Hatami, R.2    Mullin, P.3
  • 55
    • 0041846783 scopus 로고    scopus 로고
    • The bispectral index declines during neuromuscular block in fully awake persons
    • M. Messner, U. Beese, J. Romstoeck The bispectral index declines during neuromuscular block in fully awake persons Anesth Analg 97 2003 488 491
    • (2003) Anesth Analg , vol.97 , pp. 488-491
    • Messner, M.1    Beese, U.2    Romstoeck, J.3
  • 56
    • 19944364540 scopus 로고    scopus 로고
    • Antagonism of neuromuscular blockade but not muscle relaxation affects depth of anaesthesia
    • F.C. Vasella, P. Frascarolo, D.R. Spahn Antagonism of neuromuscular blockade but not muscle relaxation affects depth of anaesthesia Br J Anaesth 94 2005 742 747
    • (2005) Br J Anaesth , vol.94 , pp. 742-747
    • Vasella, F.C.1    Frascarolo, P.2    Spahn, D.R.3
  • 57
    • 7644222003 scopus 로고    scopus 로고
    • Continuous quantitative EEG monitoring in hemispheric stroke patients using the brain symmetry index
    • M.J. van Putten, D.L. Tavy Continuous quantitative EEG monitoring in hemispheric stroke patients using the brain symmetry index Stroke 35 2004 2489 2492
    • (2004) Stroke , vol.35 , pp. 2489-2492
    • Van Putten, M.J.1    Tavy, D.L.2
  • 58
    • 7444264092 scopus 로고    scopus 로고
    • Spectral entropy measurement of patient responsiveness during propofol and remifentanil. a comparison with the bispectral index
    • A.L. Vanluchene, M.M. Struys, B.E. Heyse Spectral entropy measurement of patient responsiveness during propofol and remifentanil. A comparison with the bispectral index Br J Anaesth 93 2004 645 654
    • (2004) Br J Anaesth , vol.93 , pp. 645-654
    • Vanluchene, A.L.1    Struys, M.M.2    Heyse, B.E.3
  • 59
    • 0031719760 scopus 로고    scopus 로고
    • Bispectral EEG Index during nitrous oxide administration
    • I.J. Rampil, J. Kim, R. Lenhardt Bispectral EEG Index during nitrous oxide administration Anesthesiology 89 1998 671 677
    • (1998) Anesthesiology , vol.89 , pp. 671-677
    • Rampil, I.J.1    Kim, J.2    Lenhardt, R.3
  • 60
    • 0034208467 scopus 로고    scopus 로고
    • Additional clinical observations utilizing bispectral analysis
    • N.A. Sandler Additional clinical observations utilizing bispectral analysis Anesth Prog 47 2000 84 86
    • (2000) Anesth Prog , vol.47 , pp. 84-86
    • Sandler, N.A.1
  • 61
    • 14844352442 scopus 로고    scopus 로고
    • Comparative effects of ketamine on Bispectral Index and spectral entropy of the electroencephalogram under sevoflurane anaesthesia
    • P. Hans, P.Y. Dewandre, J.F. Brichant Comparative effects of ketamine on Bispectral Index and spectral entropy of the electroencephalogram under sevoflurane anaesthesia Br J Anaesth 94 2005 336 340
    • (2005) Br J Anaesth , vol.94 , pp. 336-340
    • Hans, P.1    Dewandre, P.Y.2    Brichant, J.F.3
  • 62
    • 0141998815 scopus 로고    scopus 로고
    • Effects of nicardipine and diltiazem on the bispectral index and 95% spectral edge frequency
    • K. Hirota, S. Kabara, T. Kushikata Effects of nicardipine and diltiazem on the bispectral index and 95% spectral edge frequency Eur J Anaesthesiol 20 2003 809 812
    • (2003) Eur J Anaesthesiol , vol.20 , pp. 809-812
    • Hirota, K.1    Kabara, S.2    Kushikata, T.3
  • 63
    • 0034900131 scopus 로고    scopus 로고
    • Being awake intermittently during propofol-induced hypnosis: A study of BIS, explicit and implicit memory
    • G. Barr, R.E. Anderson, A. Owall Being awake intermittently during propofol-induced hypnosis a study of BIS, explicit and implicit memory Acta Anaesthesiol Scand 45 2001 834 838
    • (2001) Acta Anaesthesiol Scand , vol.45 , pp. 834-838
    • Barr, G.1    Anderson, R.E.2    Owall, A.3
  • 64
    • 1842663297 scopus 로고    scopus 로고
    • Spurious bispectral index values due to electromyographic activity
    • O. Baldesi, N. Bruder, L. Velly Spurious bispectral index values due to electromyographic activity Eur J Anaesthesiol 21 2004 324 325
    • (2004) Eur J Anaesthesiol , vol.21 , pp. 324-325
    • Baldesi, O.1    Bruder, N.2    Velly, L.3
  • 65
    • 0036300626 scopus 로고    scopus 로고
    • Patient State Index: Titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia
    • D.R. Drover, H.J. Lemmens, E.T. Pierce Patient State Index titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia Anesthesiology 97 2002 82 89
    • (2002) Anesthesiology , vol.97 , pp. 82-89
    • Drover, D.R.1    Lemmens, H.J.2    Pierce, E.T.3
  • 66
    • 10944250518 scopus 로고    scopus 로고
    • Patient State Index during a cardiac arrest in the operating room
    • N.K. Nguyen, F. Lenkovsky, G.P. Joshi Patient State Index during a cardiac arrest in the operating room Anesth Analg 100 2005 155 157
    • (2005) Anesth Analg , vol.100 , pp. 155-157
    • Nguyen, N.K.1    Lenkovsky, F.2    Joshi, G.P.3
  • 67
    • 3042739764 scopus 로고    scopus 로고
    • Sedation after spinal anesthesia in elderly patients: A preliminary observational study with the PSA-4000
    • V. Kurup, R. Ramani, P.G. Atanassoff Sedation after spinal anesthesia in elderly patients a preliminary observational study with the PSA-4000 Can J Anaesth 51 2004 562 571
    • (2004) Can J Anaesth , vol.51 , pp. 562-571
    • Kurup, V.1    Ramani, R.2    Atanassoff, P.G.3
  • 68
    • 28844508819 scopus 로고    scopus 로고
    • The Patient State Index as an indicator of inadequate pain management in unresponsive ICU
    • M. Ramsay, P. Huddleston, C. Henry The Patient State Index as an indicator of inadequate pain management in unresponsive ICU Crit Care Med 32 suppl 2004 A169
    • (2004) Crit Care Med , vol.32 , Issue.SUPPL. , pp. 169
    • Ramsay, M.1    Huddleston, P.2    Henry, C.3
  • 69
    • 28844474035 scopus 로고    scopus 로고
    • Is Patient State Index of EEG better than bispectral index of EEG in assessing different levels of sedation as judged by Ramsey Sedation Score in ICU patients?
    • N. Shah, A. Quijano Is Patient State Index of EEG better than bispectral index of EEG in assessing different levels of sedation as judged by Ramsey Sedation Score in ICU patients? J Neurosurg Anesthesiol 16 2004 371 372
    • (2004) J Neurosurg Anesthesiol , vol.16 , pp. 371-372
    • Shah, N.1    Quijano, A.2
  • 70
    • 0037407097 scopus 로고    scopus 로고
    • Low baseline bispectral index of the electroencephalogram in patients with dementia
    • M. Renna, J. Handy, A. Shah Low baseline bispectral index of the electroencephalogram in patients with dementia Anesth Analg 96 2003 1380 1385
    • (2003) Anesth Analg , vol.96 , pp. 1380-1385
    • Renna, M.1    Handy, J.2    Shah, A.3
  • 71
    • 0032420796 scopus 로고    scopus 로고
    • Unreasonably low bispectral index values in a volunteer with genetically determined low-voltage electroencephalographic signal
    • Y. Morimoto, T.W. Schnider, M. Luginbuhl Unreasonably low bispectral index values in a volunteer with genetically determined low-voltage electroencephalographic signal Anesthesiology 89 1998 1607 1608
    • (1998) Anesthesiology , vol.89 , pp. 1607-1608
    • Morimoto, Y.1    Schnider, T.W.2    Luginbuhl, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.