-
1
-
-
0016719282
-
[Presentation of equipment: The monitor of cerebral function.]
-
M. Dubois [Presentation of equipment the monitor of cerebral function.] Ann Anesthesiol Fr 16 1975 519 528
-
(1975)
Ann Anesthesiol Fr
, vol.16
, pp. 519-528
-
-
Dubois, M.1
-
2
-
-
0018755729
-
Development of the CFM: The Cerebral Function Analysing Monitor (CFAM)
-
D.E. Maynard Development of the CFM the Cerebral Function Analysing Monitor (CFAM) Ann Anesthesiol Fr 20 1979 253 255
-
(1979)
Ann Anesthesiol Fr
, vol.20
, pp. 253-255
-
-
Maynard, D.E.1
-
3
-
-
0021740598
-
The anesthesia and brain monitor (ABM). Concept and performance
-
B. Kay The anesthesia and brain monitor (ABM). Concept and performance Acta Anaesthesiol Belg 35 suppl 1984 167 174
-
(1984)
Acta Anaesthesiol Belg
, vol.35
, Issue.SUPPL.
, pp. 167-174
-
-
Kay, B.1
-
4
-
-
0018158128
-
The EEMG: A practical index of cortical activity and muscular relaxation
-
M.H. Harmel, F.F. Klein, D.A. Davis The EEMG a practical index of cortical activity and muscular relaxation Acta Anaesthesiol Scand Suppl 70 1978 97 102
-
(1978)
Acta Anaesthesiol Scand Suppl
, vol.70
, pp. 97-102
-
-
Harmel, M.H.1
Klein, F.F.2
Davis, D.A.3
-
5
-
-
0038298284
-
A preliminary evaluation of a new derived EEG index monitor in anesthetized patients
-
K. Willmann, S. Springman, D. Rusy A preliminary evaluation of a new derived EEG index monitor in anesthetized patients J Clin Monit Comput 17 2002 345 350
-
(2002)
J Clin Monit Comput
, vol.17
, pp. 345-350
-
-
Willmann, K.1
Springman, S.2
Rusy, D.3
-
6
-
-
1842714959
-
The Narcotrend Index: Classification algorithm, correlation with propofol effect-site concentrations, and comparison with spectral parameters
-
A. Schultz, U. Grouven, F.A. Beger The Narcotrend Index classification algorithm, correlation with propofol effect-site concentrations, and comparison with spectral parameters Biomed Tech 49 2004 38 42
-
(2004)
Biomed Tech
, vol.49
, pp. 38-42
-
-
Schultz, A.1
Grouven, U.2
Beger, F.A.3
-
7
-
-
0023796733
-
Neurological monitoring during anaesthesia and surgery
-
W.J. McMeniman, G.J. Purcell Neurological monitoring during anaesthesia and surgery Anaesth Intens Care 16 1988 358 367
-
(1988)
Anaesth Intens Care
, vol.16
, pp. 358-367
-
-
McMeniman, W.J.1
Purcell, G.J.2
-
8
-
-
0033003007
-
Bispectral index (BIS) monitoring during propofol-induced sedation and anaesthesia
-
Harbhej Singh Bispectral index (BIS) monitoring during propofol-induced sedation and anaesthesia Eur J Anaesthesiol 16 1999 31 36
-
(1999)
Eur J Anaesthesiol
, vol.16
, pp. 31-36
-
-
Harbhej, S.1
-
9
-
-
3042781777
-
Monitoring depth of anaesthesia: Is it worth the effort?
-
V. Bonnhomme, P. Hans Monitoring depth of anaesthesia is it worth the effort? Eur J Anaesthesiol 21 2004 423 428
-
(2004)
Eur J Anaesthesiol
, vol.21
, pp. 423-428
-
-
Bonnhomme, V.1
Hans, P.2
-
10
-
-
0030963250
-
A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect
-
P.S. Sebel, E. Lang, I.J. Rampil A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect Anesth Analg 84 1997 891 899
-
(1997)
Anesth Analg
, vol.84
, pp. 891-899
-
-
Sebel, P.S.1
Lang, E.2
Rampil, I.J.3
-
11
-
-
0031955145
-
Clinical utility of EEG parameters to predict loss of consciousness and response to skin incision during total intravenous anaesthesia
-
S. Schraag, U. Mohl, U. Bothner Clinical utility of EEG parameters to predict loss of consciousness and response to skin incision during total intravenous anaesthesia Anaesthesia 53 1998 320 325
-
(1998)
Anaesthesia
, vol.53
, pp. 320-325
-
-
Schraag, S.1
Mohl, U.2
Bothner, U.3
-
12
-
-
0022253402
-
Comparison of EEG monitoring techniques: An evaluation during cardiac surgery
-
A.P. Glaria, A. Murray Comparison of EEG monitoring techniques an evaluation during cardiac surgery Electroencephalogr Clin Neurophysiol 61 1985 323 330
-
(1985)
Electroencephalogr Clin Neurophysiol
, vol.61
, pp. 323-330
-
-
Glaria, A.P.1
Murray, A.2
-
13
-
-
0034010890
-
Bispectral index increases and decreases are not always signs of inadequate anesthesia
-
B. Guignard, M. Chauvin Bispectral index increases and decreases are not always signs of inadequate anesthesia Anesthesiology 92 2000 903
-
(2000)
Anesthesiology
, vol.92
, pp. 903
-
-
Guignard, B.1
Chauvin, M.2
-
14
-
-
0028935194
-
Prediction of movement using bispectral electroencephalographic analysis during propofol/alfentanil or isoflurane/alfentanil anesthesia
-
J.M. Vernon, E. Lang, P.S. Sebel Prediction of movement using bispectral electroencephalographic analysis during propofol/alfentanil or isoflurane/alfentanil anesthesia Anesth Analg 80 1995 780 785
-
(1995)
Anesth Analg
, vol.80
, pp. 780-785
-
-
Vernon, J.M.1
Lang, E.2
Sebel, P.S.3
-
15
-
-
0031657514
-
A primer for EEG signal processing in anesthesia
-
I.J. Rampil A primer for EEG signal processing in anesthesia Anesthesiology 89 1998 980 1002
-
(1998)
Anesthesiology
, vol.89
, pp. 980-1002
-
-
Rampil, I.J.1
-
16
-
-
0036300626
-
Patient state index: Titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia
-
D.R. Drover, H.J. Lemmens, E.T. Pierce Patient state index titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia Anesthesiology 97 2002 82 89
-
(2002)
Anesthesiology
, vol.97
, pp. 82-89
-
-
Drover, D.R.1
Lemmens, H.J.2
Pierce, E.T.3
-
17
-
-
23044529146
-
Should we measure depth of anesthesia
-
M. Dershwitz Should we measure depth of anesthesia Sem Anesth Perioper Med Pain 20 2001 246 256
-
(2001)
Sem Anesth Perioper Med Pain
, vol.20
, pp. 246-256
-
-
Dershwitz, M.1
-
18
-
-
28844475671
-
-
JACHO Sentinel Alert Number 32
-
Joint Commission on Accreditation of Healthcare Organizations. Awareness under anesthesia. JACHO Sentinel Alert Number 32
-
Awareness under Anesthesia
-
-
-
20
-
-
0035190820
-
Comparison of changes in electroencephalographic measures during induction of general anaesthesia: Influence of the gamma frequency band and electromyogram signal
-
J.W. Sleigh, D.A. Steyn-Ross, M.L. Steyn-Ross Comparison of changes in electroencephalographic measures during induction of general anaesthesia influence of the gamma frequency band and electromyogram signal Br J Anaesth 86 2001 50 58
-
(2001)
Br J Anaesth
, vol.86
, pp. 50-58
-
-
Sleigh, J.W.1
Steyn-Ross, D.A.2
Steyn-Ross, M.L.3
-
21
-
-
9744235773
-
Awareness and the EEG power spectrum: Analysis of frequencies
-
O. Dressler, G. Schneider, G. Stockmanns Awareness and the EEG power spectrum analysis of frequencies Br J Anaesth 93 2004 806 809
-
(2004)
Br J Anaesth
, vol.93
, pp. 806-809
-
-
Dressler, O.1
Schneider, G.2
Stockmanns, G.3
-
22
-
-
20144364884
-
Cognitive avionics and watching spaceflight crews think: Generation-after-next research tools in functional neuroimaging
-
R.J. Genik 2nd, C.C. Green, F.X. Graydon Cognitive avionics and watching spaceflight crews think generation-after-next research tools in functional neuroimaging Aviat Space Environ Med 76 suppl 6 2005 B208 B212
-
(2005)
Aviat Space Environ Med
, vol.76
, Issue.6 SUPPL.
-
-
Genik II, R.J.1
Green, C.C.2
Graydon, F.X.3
-
23
-
-
0028110368
-
The electroencephalogram does not predict depth of isoflurane anesthesia
-
R.C. Dwyer, I.J. Rampil, E.N. Eger The electroencephalogram does not predict depth of isoflurane anesthesia Anesthesiology 81 1994 403 409
-
(1994)
Anesthesiology
, vol.81
, pp. 403-409
-
-
Dwyer, R.C.1
Rampil, I.J.2
Eger, E.N.3
-
24
-
-
0031934912
-
Electroencephalographic derivatives as a tool for predicting depth of sedation and anesthesia induced by sevoflurane
-
T. Katoh, A. Suzuki, T. Ikeda Electroencephalographic derivatives as a tool for predicting depth of sedation and anesthesia induced by sevoflurane Anesthesiology 88 1998 642 650
-
(1998)
Anesthesiology
, vol.88
, pp. 642-650
-
-
Katoh, T.1
Suzuki, A.2
Ikeda, T.3
-
25
-
-
0033970358
-
Influence of age on hypnotic requirement, Bispectral Index, and 95% spectral edge frequency associated with sedation induced by sevoflurane
-
T. Katoh, H. Bito, S. Sato Influence of age on hypnotic requirement, Bispectral Index, and 95% spectral edge frequency associated with sedation induced by sevoflurane Anesthesiology 92 2000 55 66
-
(2000)
Anesthesiology
, vol.92
, pp. 55-66
-
-
Katoh, T.1
Bito, H.2
Sato, S.3
-
27
-
-
0031876291
-
Quantitative EEG correlations with brain glucose metabolic rate during anesthesia in volunteers
-
M.T. Alkire Quantitative EEG correlations with brain glucose metabolic rate during anesthesia in volunteers Anesthesiology 89 1998 323 333
-
(1998)
Anesthesiology
, vol.89
, pp. 323-333
-
-
Alkire, M.T.1
-
28
-
-
0016616321
-
Cerebral protection by anaesthetics during ischaemia
-
J.D. Michenfelder, J.D. Milde Cerebral protection by anaesthetics during ischaemia Resuscitation 4 1975 219
-
(1975)
Resuscitation
, vol.4
, pp. 219
-
-
Michenfelder, J.D.1
Milde, J.D.2
-
29
-
-
10944222205
-
Anesthetic management and one-year mortality after noncardiac surgery
-
T.G. Monk, V. Saini, B.C. Weldon Anesthetic management and one-year mortality after noncardiac surgery Anesth Analg 100 2005 4 10
-
(2005)
Anesth Analg
, vol.100
, pp. 4-10
-
-
Monk, T.G.1
Saini, V.2
Weldon, B.C.3
-
30
-
-
10344244507
-
Emergency EEG and continuous EEG monitoring in acute ischemic stroke
-
K.G. Jordan Emergency EEG and continuous EEG monitoring in acute ischemic stroke J Clin Neurophysiol 21 2004 341 352
-
(2004)
J Clin Neurophysiol
, vol.21
, pp. 341-352
-
-
Jordan, K.G.1
-
31
-
-
0018956806
-
Relationship of intraoperative EEG monitoring and stump pressure measurements during carotid endarterectomy
-
D.C. Brewster, P.J. O'Hara, R.C. Darling Relationship of intraoperative EEG monitoring and stump pressure measurements during carotid endarterectomy Circulation 62 1980 I4 I7
-
(1980)
Circulation
, vol.62
-
-
Brewster, D.C.1
O'Hara, P.J.2
Darling, R.C.3
-
32
-
-
0026742766
-
Computerized electroencephalographic monitoring and selective shunting: Influence on intraoperative administration of phenylephrine and myocardial infarction after general anesthesia for carotid endarterectomy
-
P.A. Modica, R. Tempelhoff, K.M. Rich Computerized electroencephalographic monitoring and selective shunting influence on intraoperative administration of phenylephrine and myocardial infarction after general anesthesia for carotid endarterectomy Neurosurgery 30 1992 842 846
-
(1992)
Neurosurgery
, vol.30
, pp. 842-846
-
-
Modica, P.A.1
Tempelhoff, R.2
Rich, K.M.3
-
33
-
-
0020634366
-
Computerized electroencephalogram monitoring and carotid artery shunting
-
I. Rampil, J.W. Correll, S.H. Rosenbaum Computerized electroencephalogram monitoring and carotid artery shunting Neurosurgery 13 1983 276
-
(1983)
Neurosurgery
, vol.13
, pp. 276
-
-
Rampil, I.1
Correll, J.W.2
Rosenbaum, S.H.3
-
34
-
-
0036894508
-
A comparison of patient state index and bispectral index values during the perioperative period
-
X. Chen, J. Tang, P.F. White A comparison of patient state index and bispectral index values during the perioperative period Anesth Analg 95 2002 1669 1674
-
(2002)
Anesth Analg
, vol.95
, pp. 1669-1674
-
-
Chen, X.1
Tang, J.2
White, P.F.3
-
35
-
-
6444233480
-
Is the patient state analyzer with the PSArray2 a cost-effective alternative to the bispectral index monitor during the perioperative period?
-
P.F. White, J. Tang, H. Ma Is the patient state analyzer with the PSArray2 a cost-effective alternative to the bispectral index monitor during the perioperative period? Anesth Analg 99 2004 1429 1435
-
(2004)
Anesth Analg
, vol.99
, pp. 1429-1435
-
-
White, P.F.1
Tang, J.2
Ma, H.3
-
36
-
-
0030664906
-
Temporary occlusion of the middle cerebral artery in intracranial aneurysm surgery: Time limitation and advantage of brain protection
-
S.D. Lavine, L.S. Maseri, M.L. Levy Temporary occlusion of the middle cerebral artery in intracranial aneurysm surgery time limitation and advantage of brain protection J Neurosurg 87 1997 817 824
-
(1997)
J Neurosurg
, vol.87
, pp. 817-824
-
-
Lavine, S.D.1
Maseri, L.S.2
Levy, M.L.3
-
37
-
-
0242474260
-
A marked decrease in bispectral index with elevation of suppression ratio by cervical haematoma reducing cerebral perfusion pressure
-
N. Umegaki, K. Hirota, M. Kitayama A marked decrease in bispectral index with elevation of suppression ratio by cervical haematoma reducing cerebral perfusion pressure J Clin Neurosci 10 2003 694 696
-
(2003)
J Clin Neurosci
, vol.10
, pp. 694-696
-
-
Umegaki, N.1
Hirota, K.2
Kitayama, M.3
-
38
-
-
0022360315
-
The power spectrum analyser as an indicator of cerebral ischaemia during carotid endarterectomy
-
M.A. Ashburn, L.B. Mitchell, D.F. Dean The power spectrum analyser as an indicator of cerebral ischaemia during carotid endarterectomy Anaesth Intens Care 13 1985 387 391
-
(1985)
Anaesth Intens Care
, vol.13
, pp. 387-391
-
-
Ashburn, M.A.1
Mitchell, L.B.2
Dean, D.F.3
-
39
-
-
0024562838
-
Selective shunting during carotid endarterectomy based on two-channel computerized electroencephalographic/compressed spectral array analysis
-
R. Tempelhoff, P.A. Modica, R.L. Grubb Jr Selective shunting during carotid endarterectomy based on two-channel computerized electroencephalographic/compressed spectral array analysis Neurosurgery 24 1989 339 344
-
(1989)
Neurosurgery
, vol.24
, pp. 339-344
-
-
Tempelhoff, R.1
Modica, P.A.2
Grubb Jr., R.L.3
-
40
-
-
0024351543
-
Balloon test occlusion of the internal carotid artery with monitoring of compressed spectral arrays (CSAs) of electroencephalogram
-
T. Morioka, T. Matsushima, K. Fujii Balloon test occlusion of the internal carotid artery with monitoring of compressed spectral arrays (CSAs) of electroencephalogram Acta Neurochir (Wien) 101 1989 29 34
-
(1989)
Acta Neurochir (Wien)
, vol.101
, pp. 29-34
-
-
Morioka, T.1
Matsushima, T.2
Fujii, K.3
-
41
-
-
5744253296
-
Fatal ischemia stroke in a patient with an asymptomatic carotid artery occlusion after lumbar spine surgery: A case report
-
L.C. Wang, J.T. Liou, F.C. Liu Fatal ischemia stroke in a patient with an asymptomatic carotid artery occlusion after lumbar spine surgery a case report Acta Anaesthesiol Taiwan 42 2004 179 182
-
(2004)
Acta Anaesthesiol Taiwan
, vol.42
, pp. 179-182
-
-
Wang, L.C.1
Liou, J.T.2
Liu, F.C.3
-
42
-
-
2542562742
-
Bispectral index monitoring to prevent awareness during anaesthesia: The B-Aware randomised controlled trial
-
P. Myles, K. Leslie, J. McNeil Bispectral index monitoring to prevent awareness during anaesthesia the B-Aware randomised controlled trial Lancet 363 2004 1757 1763
-
(2004)
Lancet
, vol.363
, pp. 1757-1763
-
-
Myles, P.1
Leslie, K.2
McNeil, J.3
-
43
-
-
10744225339
-
The Patient State Index as an indicator of the level of hypnosis under general anaesthesia
-
L.S. Prichep, L.D. Gugino, E.R. John The Patient State Index as an indicator of the level of hypnosis under general anaesthesia Br J Anaesth 92 2004 393 399
-
(2004)
Br J Anaesth
, vol.92
, pp. 393-399
-
-
Prichep, L.S.1
Gugino, L.D.2
John, E.R.3
-
44
-
-
1942468900
-
Comparative evaluation of Narcotrend, Bispectral Index, and classical electroencephalographic variables during induction, maintenance, and emergence of a propofol/remifentanil anesthesia
-
G.N. Schmidt, P. Bischoff, T. Standl Comparative evaluation of Narcotrend, Bispectral Index, and classical electroencephalographic variables during induction, maintenance, and emergence of a propofol/remifentanil anesthesia Anesth Analg 98 2004 1346 1353
-
(2004)
Anesth Analg
, vol.98
, pp. 1346-1353
-
-
Schmidt, G.N.1
Bischoff, P.2
Standl, T.3
-
45
-
-
1842592081
-
Bispectral electroencephalographic analysis of head-injured patients in the emergency department
-
E. Haug, J. Miner, M. Dannehy Bispectral electroencephalographic analysis of head-injured patients in the emergency department Acad Emerg Med 11 2004 349 352
-
(2004)
Acad Emerg Med
, vol.11
, pp. 349-352
-
-
Haug, E.1
Miner, J.2
Dannehy, M.3
-
46
-
-
0242467596
-
Decreased bispectral index as an indicator of syncope before hypotension and bradycardia in two patients with needle phobia
-
N.N. Win, H. Kohase, T. Miyamoto Decreased bispectral index as an indicator of syncope before hypotension and bradycardia in two patients with needle phobia Br J Anaesth 91 2003 749 752
-
(2003)
Br J Anaesth
, vol.91
, pp. 749-752
-
-
Win, N.N.1
Kohase, H.2
Miyamoto, T.3
-
47
-
-
10944273953
-
The detection of cerebral hypoperfusion with Bispectral Index monitoring during general anesthesia
-
Monden, Yoko, K. Ohtake, T. Sakabe The detection of cerebral hypoperfusion with Bispectral Index monitoring during general anesthesia Anesth Analg 100 2005 158 161
-
(2005)
Anesth Analg
, vol.100
, pp. 158-161
-
-
Monden1
Yoko2
Ohtake, K.3
Sakabe, T.4
-
48
-
-
2942543376
-
The use of bispectral index during a cardiopulmonary arrest: A potential predictor of cerebral perfusion
-
N. Azim, C.Y. Wang The use of bispectral index during a cardiopulmonary arrest a potential predictor of cerebral perfusion Anaesthesia 59 2004 610 612
-
(2004)
Anaesthesia
, vol.59
, pp. 610-612
-
-
Azim, N.1
Wang, C.Y.2
-
49
-
-
23144433260
-
Use of the bispectral index during the early postresuscitative phase after out-of-hospital cardiac arrest
-
S. Shibata, T. Imota, S. Shigeomi Use of the bispectral index during the early postresuscitative phase after out-of-hospital cardiac arrest J Anesth 19 2005 243 246
-
(2005)
J Anesth
, vol.19
, pp. 243-246
-
-
Shibata, S.1
Imota, T.2
Shigeomi, S.3
-
50
-
-
0642274955
-
EEG bispectral index during carotid endarterectomy
-
A.A. el-Dawlatly EEG bispectral index during carotid endarterectomy Middle East J Anesthesiol 17 2003 287 293
-
(2003)
Middle East J Anesthesiol
, vol.17
, pp. 287-293
-
-
El-Dawlatly, A.A.1
-
51
-
-
0035528833
-
[BIS monitoring may allow the detection of severe cerebral ischemia.]
-
S. Merat, J.P. Levecque, Y. Le Gulluche [BIS monitoring may allow the detection of severe cerebral ischemia.] Can J Anaesth 48 2001 1066 1069
-
(2001)
Can J Anaesth
, vol.48
, pp. 1066-1069
-
-
Merat, S.1
Levecque, J.P.2
Le Gulluche, Y.3
-
52
-
-
19944384934
-
Bispectral index monitoring may not reliably indicate cerebral ischaemia during awake carotid endarterectomy
-
A. Deogaonkar, R. Vivar, R.E. Bullock Bispectral index monitoring may not reliably indicate cerebral ischaemia during awake carotid endarterectomy Br J Anaesth 94 2005 800 804
-
(2005)
Br J Anaesth
, vol.94
, pp. 800-804
-
-
Deogaonkar, A.1
Vivar, R.2
Bullock, R.E.3
-
53
-
-
1342346199
-
Anaesthesia for carotid endarterectomy: Comparison of hypnotic- and opioid-based techniques
-
G. Godet, M. Reina, M. Raux Anaesthesia for carotid endarterectomy comparison of hypnotic- and opioid-based techniques Br J Anaesth 92 2004 329 334
-
(2004)
Br J Anaesth
, vol.92
, pp. 329-334
-
-
Godet, G.1
Reina, M.2
Raux, M.3
-
54
-
-
20744434829
-
Bilateral bispectral index monitoring during suppression of unilateral hemispheric function
-
H. Heller, R. Hatami, P. Mullin Bilateral bispectral index monitoring during suppression of unilateral hemispheric function Anesth Analg 101 2005 235 241
-
(2005)
Anesth Analg
, vol.101
, pp. 235-241
-
-
Heller, H.1
Hatami, R.2
Mullin, P.3
-
55
-
-
0041846783
-
The bispectral index declines during neuromuscular block in fully awake persons
-
M. Messner, U. Beese, J. Romstoeck The bispectral index declines during neuromuscular block in fully awake persons Anesth Analg 97 2003 488 491
-
(2003)
Anesth Analg
, vol.97
, pp. 488-491
-
-
Messner, M.1
Beese, U.2
Romstoeck, J.3
-
56
-
-
19944364540
-
Antagonism of neuromuscular blockade but not muscle relaxation affects depth of anaesthesia
-
F.C. Vasella, P. Frascarolo, D.R. Spahn Antagonism of neuromuscular blockade but not muscle relaxation affects depth of anaesthesia Br J Anaesth 94 2005 742 747
-
(2005)
Br J Anaesth
, vol.94
, pp. 742-747
-
-
Vasella, F.C.1
Frascarolo, P.2
Spahn, D.R.3
-
57
-
-
7644222003
-
Continuous quantitative EEG monitoring in hemispheric stroke patients using the brain symmetry index
-
M.J. van Putten, D.L. Tavy Continuous quantitative EEG monitoring in hemispheric stroke patients using the brain symmetry index Stroke 35 2004 2489 2492
-
(2004)
Stroke
, vol.35
, pp. 2489-2492
-
-
Van Putten, M.J.1
Tavy, D.L.2
-
58
-
-
7444264092
-
Spectral entropy measurement of patient responsiveness during propofol and remifentanil. a comparison with the bispectral index
-
A.L. Vanluchene, M.M. Struys, B.E. Heyse Spectral entropy measurement of patient responsiveness during propofol and remifentanil. A comparison with the bispectral index Br J Anaesth 93 2004 645 654
-
(2004)
Br J Anaesth
, vol.93
, pp. 645-654
-
-
Vanluchene, A.L.1
Struys, M.M.2
Heyse, B.E.3
-
59
-
-
0031719760
-
Bispectral EEG Index during nitrous oxide administration
-
I.J. Rampil, J. Kim, R. Lenhardt Bispectral EEG Index during nitrous oxide administration Anesthesiology 89 1998 671 677
-
(1998)
Anesthesiology
, vol.89
, pp. 671-677
-
-
Rampil, I.J.1
Kim, J.2
Lenhardt, R.3
-
60
-
-
0034208467
-
Additional clinical observations utilizing bispectral analysis
-
N.A. Sandler Additional clinical observations utilizing bispectral analysis Anesth Prog 47 2000 84 86
-
(2000)
Anesth Prog
, vol.47
, pp. 84-86
-
-
Sandler, N.A.1
-
61
-
-
14844352442
-
Comparative effects of ketamine on Bispectral Index and spectral entropy of the electroencephalogram under sevoflurane anaesthesia
-
P. Hans, P.Y. Dewandre, J.F. Brichant Comparative effects of ketamine on Bispectral Index and spectral entropy of the electroencephalogram under sevoflurane anaesthesia Br J Anaesth 94 2005 336 340
-
(2005)
Br J Anaesth
, vol.94
, pp. 336-340
-
-
Hans, P.1
Dewandre, P.Y.2
Brichant, J.F.3
-
62
-
-
0141998815
-
Effects of nicardipine and diltiazem on the bispectral index and 95% spectral edge frequency
-
K. Hirota, S. Kabara, T. Kushikata Effects of nicardipine and diltiazem on the bispectral index and 95% spectral edge frequency Eur J Anaesthesiol 20 2003 809 812
-
(2003)
Eur J Anaesthesiol
, vol.20
, pp. 809-812
-
-
Hirota, K.1
Kabara, S.2
Kushikata, T.3
-
63
-
-
0034900131
-
Being awake intermittently during propofol-induced hypnosis: A study of BIS, explicit and implicit memory
-
G. Barr, R.E. Anderson, A. Owall Being awake intermittently during propofol-induced hypnosis a study of BIS, explicit and implicit memory Acta Anaesthesiol Scand 45 2001 834 838
-
(2001)
Acta Anaesthesiol Scand
, vol.45
, pp. 834-838
-
-
Barr, G.1
Anderson, R.E.2
Owall, A.3
-
64
-
-
1842663297
-
Spurious bispectral index values due to electromyographic activity
-
O. Baldesi, N. Bruder, L. Velly Spurious bispectral index values due to electromyographic activity Eur J Anaesthesiol 21 2004 324 325
-
(2004)
Eur J Anaesthesiol
, vol.21
, pp. 324-325
-
-
Baldesi, O.1
Bruder, N.2
Velly, L.3
-
65
-
-
0036300626
-
Patient State Index: Titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia
-
D.R. Drover, H.J. Lemmens, E.T. Pierce Patient State Index titration of delivery and recovery from propofol, alfentanil, and nitrous oxide anesthesia Anesthesiology 97 2002 82 89
-
(2002)
Anesthesiology
, vol.97
, pp. 82-89
-
-
Drover, D.R.1
Lemmens, H.J.2
Pierce, E.T.3
-
66
-
-
10944250518
-
Patient State Index during a cardiac arrest in the operating room
-
N.K. Nguyen, F. Lenkovsky, G.P. Joshi Patient State Index during a cardiac arrest in the operating room Anesth Analg 100 2005 155 157
-
(2005)
Anesth Analg
, vol.100
, pp. 155-157
-
-
Nguyen, N.K.1
Lenkovsky, F.2
Joshi, G.P.3
-
67
-
-
3042739764
-
Sedation after spinal anesthesia in elderly patients: A preliminary observational study with the PSA-4000
-
V. Kurup, R. Ramani, P.G. Atanassoff Sedation after spinal anesthesia in elderly patients a preliminary observational study with the PSA-4000 Can J Anaesth 51 2004 562 571
-
(2004)
Can J Anaesth
, vol.51
, pp. 562-571
-
-
Kurup, V.1
Ramani, R.2
Atanassoff, P.G.3
-
68
-
-
28844508819
-
The Patient State Index as an indicator of inadequate pain management in unresponsive ICU
-
M. Ramsay, P. Huddleston, C. Henry The Patient State Index as an indicator of inadequate pain management in unresponsive ICU Crit Care Med 32 suppl 2004 A169
-
(2004)
Crit Care Med
, vol.32
, Issue.SUPPL.
, pp. 169
-
-
Ramsay, M.1
Huddleston, P.2
Henry, C.3
-
69
-
-
28844474035
-
Is Patient State Index of EEG better than bispectral index of EEG in assessing different levels of sedation as judged by Ramsey Sedation Score in ICU patients?
-
N. Shah, A. Quijano Is Patient State Index of EEG better than bispectral index of EEG in assessing different levels of sedation as judged by Ramsey Sedation Score in ICU patients? J Neurosurg Anesthesiol 16 2004 371 372
-
(2004)
J Neurosurg Anesthesiol
, vol.16
, pp. 371-372
-
-
Shah, N.1
Quijano, A.2
-
70
-
-
0037407097
-
Low baseline bispectral index of the electroencephalogram in patients with dementia
-
M. Renna, J. Handy, A. Shah Low baseline bispectral index of the electroencephalogram in patients with dementia Anesth Analg 96 2003 1380 1385
-
(2003)
Anesth Analg
, vol.96
, pp. 1380-1385
-
-
Renna, M.1
Handy, J.2
Shah, A.3
-
71
-
-
0032420796
-
Unreasonably low bispectral index values in a volunteer with genetically determined low-voltage electroencephalographic signal
-
Y. Morimoto, T.W. Schnider, M. Luginbuhl Unreasonably low bispectral index values in a volunteer with genetically determined low-voltage electroencephalographic signal Anesthesiology 89 1998 1607 1608
-
(1998)
Anesthesiology
, vol.89
, pp. 1607-1608
-
-
Morimoto, Y.1
Schnider, T.W.2
Luginbuhl, M.3
|