메뉴 건너뛰기




Volumn 24, Issue 8, 2005, Pages 988-993

The Horwitz curve is too optimistic for analyses in plastics

Author keywords

Antioxidants; Flame retardants; Homogeneity; Horwitz curve; Interlaboratory reproducibility; Plasticizers; Plastics; Trace elements in plastics

Indexed keywords

ANTIOXIDANTS; CONCENTRATION (PROCESS); FLAME RETARDANTS; PLASTICIZERS; TRACE ELEMENTS;

EID: 28544440268     PISSN: 01429418     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.polymertesting.2005.08.003     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 0019089066 scopus 로고
    • Quality assurance in the analysis of foods for trace constituents
    • W. Horwitz, L.R. Kamps, and K.W. Boyer Quality assurance in the analysis of foods for trace constituents J. Assoc. Off. Anal. Chem. 63 1980 1344
    • (1980) J. Assoc. Off. Anal. Chem. , vol.63 , pp. 1344
    • Horwitz, W.1    Kamps, L.R.2    Boyer, K.W.3
  • 2
    • 0021993532 scopus 로고
    • Interlaboratory variability in trace element analysis
    • K.W. Boyer, W. Horwitz, and R. Albert Interlaboratory variability in trace element analysis Anal. Chem. 57 1985 454
    • (1985) Anal. Chem. , vol.57 , pp. 454
    • Boyer, K.W.1    Horwitz, W.2    Albert, R.3
  • 3
    • 0001072608 scopus 로고    scopus 로고
    • A heuristic derivation of the Horwitz curve
    • R. Albert, and W. Horwitz A heuristic derivation of the Horwitz curve Anal. Chem. 69 1997 789
    • (1997) Anal. Chem. , vol.69 , pp. 789
    • Albert, R.1    Horwitz, W.2
  • 4
    • 0034110836 scopus 로고    scopus 로고
    • Recent trends in inter-laboratory precision at ppb and sub-ppb concentrations in relation to fitness for purpose criteria in proficiency testing
    • M. Thompson Recent trends in inter-laboratory precision at ppb and sub-ppb concentrations in relation to fitness for purpose criteria in proficiency testing Analyst 125 2000 385
    • (2000) Analyst , vol.125 , pp. 385
    • Thompson, M.1
  • 5
    • 0042230910 scopus 로고    scopus 로고
    • Measurement uncertainty and doping control in sport
    • A.M.H. van der Veen Measurement uncertainty and doping control in sport Accred. Qual. Assur. 8 2003 334
    • (2003) Accred. Qual. Assur. , vol.8 , pp. 334
    • Van Der Veen, A.M.H.1
  • 7
    • 16344378281 scopus 로고    scopus 로고
    • Interlaboratory test on polymers: Determination of anitoxidants in polyolefins
    • A. Ritter, E. Michel, M. Schmid, and S. Affolter Interlaboratory test on polymers: determination of anitoxidants in polyolefins Polym. Test. 24 2005 498
    • (2005) Polym. Test. , vol.24 , pp. 498
    • Ritter, A.1    Michel, E.2    Schmid, M.3    Affolter, S.4
  • 8
    • 28544451472 scopus 로고    scopus 로고
    • http://www.iisnl.com.
  • 9
    • 28544449459 scopus 로고    scopus 로고
    • Probenaufbereitungs- und analyseverfahren für flammschutzmittel in erzeugnissen
    • Federal Institute for Materials Research and Testing, Berlin, Germany
    • S. Kemmlein, M. Bergmann, O. Jann, Probenaufbereitungs- und Analyseverfahren für Flammschutzmittel in Erzeugnissen, Federal Institute for Materials Research and Testing, Berlin, Germany. Forschungs bericht UFOPLAN 202 67 300 (2005).
    • (2005) Forschungs Bericht UFOPLAN , vol.202 , Issue.67 , pp. 300
    • Kemmlein, S.1    Bergmann, M.2    Jann, O.3
  • 10
    • 2342599112 scopus 로고    scopus 로고
    • Interlaboratory test on polymers: Determination of heavy metals in polymer matrices
    • A. Ritter, E. Michel, M. Schmid, and S. Affolter Interlaboratory test on polymers: determination of heavy metals in polymer matrices Polym. Test. 23 2004 467
    • (2004) Polym. Test. , vol.23 , pp. 467
    • Ritter, A.1    Michel, E.2    Schmid, M.3    Affolter, S.4
  • 12
    • 28544451360 scopus 로고    scopus 로고
    • Personal Communication
    • W. Horwitz, Personal Communication, 2002.
    • (2002)
    • Horwitz, W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.