메뉴 건너뛰기




Volumn 54, Issue 6, 2005, Pages 1562-1568

Interleaved acquisition of lipid and water images of the heart using a double-inversion fast spin-echo method

Author keywords

ARVD; Cardiac; Fast spin echo; Lipid; MRI

Indexed keywords

HEART; LIPIDS; MAGNETIC RESONANCE IMAGING; SPIN POLARIZATION;

EID: 28444475178     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20691     Document Type: Article
Times cited : (3)

References (20)
  • 1
    • 2242482814 scopus 로고    scopus 로고
    • Arrhythmogenic right ventricular dysplasia
    • Marcus FI. Arrhythmogenic right ventricular dysplasia. Cardiac Electrophysiol Rev 1999;3:45-46.
    • (1999) Cardiac Electrophysiol Rev , vol.3 , pp. 45-46
    • Marcus, F.I.1
  • 2
  • 3
    • 0030459226 scopus 로고    scopus 로고
    • Spin-echo nuclear magnetic resonance for tissue characterisation in arrhythmogenic right ventricular cardiomyopathy
    • Menghetti L, Basso C, Nava A, Angelini A, Thiene G. Spin-echo nuclear magnetic resonance for tissue characterisation in arrhythmogenic right ventricular cardiomyopathy. Heart 1996;76:467-470.
    • (1996) Heart , vol.76 , pp. 467-470
    • Menghetti, L.1    Basso, C.2    Nava, A.3    Angelini, A.4    Thiene, G.5
  • 6
    • 0029978378 scopus 로고    scopus 로고
    • "Black blood" T2-weighted inversion-recovery MR imaging of the heart
    • Simonetti OP, Finn JP, White RD, Laub G, Henry DA. "Black blood" T2-weighted inversion-recovery MR imaging of the heart. Radiology 1996;199:49-57.
    • (1996) Radiology , vol.199 , pp. 49-57
    • Simonetti, O.P.1    Finn, J.P.2    White, R.D.3    Laub, G.4    Henry, D.A.5
  • 10
    • 0026467251 scopus 로고
    • The loss of small objects in variable TE imaging: Implications for FSE, RARE, and EPI
    • Constable RT, Gore JC. The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn Reson Med 1992;28:9-24.
    • (1992) Magn Reson Med , vol.28 , pp. 9-24
    • Constable, R.T.1    Gore, J.C.2
  • 14
    • 0030872283 scopus 로고    scopus 로고
    • Highly selective water and fat imaging applying multislice sequences without sensitivity to B1 field inhomogeneities
    • Schick F, Forster J, Machann J, Huppert P, Claussen CD. Highly selective water and fat imaging applying multislice sequences without sensitivity to B1 field inhomogeneities Magn Reson Med 1997;38:269-274.
    • (1997) Magn Reson Med , vol.38 , pp. 269-274
    • Schick, F.1    Forster, J.2    Machann, J.3    Huppert, P.4    Claussen, C.D.5
  • 15
    • 0031862930 scopus 로고    scopus 로고
    • In vivo measurement of T2* and field inhomogeneity maps in the human heart at 1.5 T
    • Reeder SB, Faranesh AZ, Boxerman JL, McVeigh ER. In vivo measurement of T2* and field inhomogeneity maps in the human heart at 1.5 T. Magn Reson Med 1998;39:988-998.
    • (1998) Magn Reson Med , vol.39 , pp. 988-998
    • Reeder, S.B.1    Faranesh, A.Z.2    Boxerman, J.L.3    McVeigh, E.R.4
  • 16
    • 19544389162 scopus 로고    scopus 로고
    • Radial Acquisition of Data (RAD) GRASE: Implementation and clinical applications
    • Gmitro AF, Kono M, Theilmann RJ, Altbach MI, Trouard TP. Radial Acquisition of Data (RAD) GRASE: Implementation and clinical applications. Magn Reson Med 2005;53:1363-1371.
    • (2005) Magn Reson Med , vol.53 , pp. 1363-1371
    • Gmitro, A.F.1    Kono, M.2    Theilmann, R.J.3    Altbach, M.I.4    Trouard, T.P.5
  • 19
    • 0036184749 scopus 로고    scopus 로고
    • Multislice double inversion pulse sequence for efficient black-blood MRI
    • Song HK, Wright AC, Wolf RL, Wehrli FW. Multislice double inversion pulse sequence for efficient black-blood MRI. Magn Reson Med 2002; 47:616-620.
    • (2002) Magn Reson Med , vol.47 , pp. 616-620
    • Song, H.K.1    Wright, A.C.2    Wolf, R.L.3    Wehrli, F.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.