1
-
-
0035161282
-
Immunosensors: Principles and application to clinical chemistry
-
P.B. Luppa, L.J. Sokoll, and D.W. Chan Immunosensors: principles and application to clinical chemistry Clin. Chim. Acta 314 2001 1 26
-
(2001)
Clin. Chim. Acta
, vol.314
, pp. 1-26
-
-
Luppa, P.B.1
Sokoll, L.J.2
Chan, D.W.3
-
2
-
-
0032897550
-
Immunoassay and other ligand assays: From isotopes to luminescence
-
R. Ekins Immunoassay and other ligand assays: from isotopes to luminescence J. Clin. Ligand Assay 22 1999 61 77
-
(1999)
J. Clin. Ligand Assay
, vol.22
, pp. 61-77
-
-
Ekins, R.1
-
6
-
-
0031176184
-
Self-assembled monolayers with biospecific affinity for lactate dehydrogenase for the electroenzymatic oxidation of lactate
-
D.D. Schlereth, and R. Kooyman Self-assembled monolayers with biospecific affinity for lactate dehydrogenase for the electroenzymatic oxidation of lactate J. Electroanal. Chem. 431 1997 285 295
-
(1997)
J. Electroanal. Chem.
, vol.431
, pp. 285-295
-
-
Schlereth, D.D.1
Kooyman, R.2
-
7
-
-
0033013201
-
Optimization of capacitive affinity sensors: Drift suppression and signal amplification
-
M. Riepl, V.M. Mirsky, I. Novotny, V. Tvarozek, V. Rehacek, and O.S. Wolfbeis Optimization of capacitive affinity sensors: drift suppression and signal amplification Anal. Chim. Acta 392 1999 77 84
-
(1999)
Anal. Chim. Acta
, vol.392
, pp. 77-84
-
-
Riepl, M.1
Mirsky, V.M.2
Novotny, I.3
Tvarozek, V.4
Rehacek, V.5
Wolfbeis, O.S.6
-
8
-
-
0035281546
-
Development of an electrochemical immunosensor for direct detection of interferon-γ at the attomolar level
-
M. Dijksma, B. Kamp, J.C. Hoogvliet, and W.P. van Bennekom Development of an electrochemical immunosensor for direct detection of interferon-γ at the attomolar level Anal. Chem. 73 2001 901 907
-
(2001)
Anal. Chem.
, vol.73
, pp. 901-907
-
-
Dijksma, M.1
Kamp, B.2
Hoogvliet, J.C.3
Van Bennekom, W.P.4
-
9
-
-
0031277606
-
Capacitive monitoring of protein immobilization and antigen-antibody reactions on monomolecular alkylthiol films on gold electrodes
-
V.M. Mirsky, M. Riepl, and O.S. Wolfbeis Capacitive monitoring of protein immobilization and antigen-antibody reactions on monomolecular alkylthiol films on gold electrodes Biosens. Bioelectron. 12 1997 977 989
-
(1997)
Biosens. Bioelectron.
, vol.12
, pp. 977-989
-
-
Mirsky, V.M.1
Riepl, M.2
Wolfbeis, O.S.3
-
10
-
-
0034429880
-
Antibodies and immunoassays
-
S. Madersbacher, and P. Berger Antibodies and immunoassays Methods 21 2000 41 50
-
(2000)
Methods
, vol.21
, pp. 41-50
-
-
Madersbacher, S.1
Berger, P.2
-
12
-
-
0036873472
-
Survey of the year 2001 commercial optical biosensor literature
-
R.L. Rich, and D.G. Myszka Survey of the year 2001 commercial optical biosensor literature J. Mol. Recogn. 15 2002 352 376
-
(2002)
J. Mol. Recogn.
, vol.15
, pp. 352-376
-
-
Rich, R.L.1
Myszka, D.G.2
-
13
-
-
0026153423
-
Quantitative determination of surface concentration of protein with surface plasmon resonance using radiolabeled proteins
-
E. Stenberg, B. Persson, H. Roos, and C. Urbaniczky Quantitative determination of surface concentration of protein with surface plasmon resonance using radiolabeled proteins J. Colloid Interface Sci. 143 1991 513 526
-
(1991)
J. Colloid Interface Sci.
, vol.143
, pp. 513-526
-
-
Stenberg, E.1
Persson, B.2
Roos, H.3
Urbaniczky, C.4
-
14
-
-
0038699076
-
Covalently coupling the antibody on an amine-self-assembled gold surface to probe hyaluronan-binding protein with capacitance measurement
-
D. Jiang, J. Tang, B. Liu, P. Yang, X. Shen, and J. Kong Covalently coupling the antibody on an amine-self-assembled gold surface to probe hyaluronan-binding protein with capacitance measurement Biosens. Bioelectron. 18 2003 1183 1191
-
(2003)
Biosens. Bioelectron.
, vol.18
, pp. 1183-1191
-
-
Jiang, D.1
Tang, J.2
Liu, B.3
Yang, P.4
Shen, X.5
Kong, J.6
-
15
-
-
0037029928
-
Capacitive immunosensor for transferrin based on an o-aminobenzenthiol oligomer layer
-
S.Q. Hu, Z.Y. Wu, Y.M. Zhou, Z.X. Cao, G.L. Shen, and R.Q. Yu Capacitive immunosensor for transferrin based on an o-aminobenzenthiol oligomer layer Anal. Chim. Acta 458 2002 297 304
-
(2002)
Anal. Chim. Acta
, vol.458
, pp. 297-304
-
-
Hu, S.Q.1
Wu, Z.Y.2
Zhou, Y.M.3
Cao, Z.X.4
Shen, G.L.5
Yu, R.Q.6
-
16
-
-
0031658186
-
Capacitive immunosensing of polycyclic aromatic hydrocarbon and protein conjugates
-
M. Liu, G.A. Rechnitz, K. Li, and Q.X. Li Capacitive immunosensing of polycyclic aromatic hydrocarbon and protein conjugates Anal. Lett. 31 1998 2025 2038
-
(1998)
Anal. Lett.
, vol.31
, pp. 2025-2038
-
-
Liu, M.1
Rechnitz, G.A.2
Li, K.3
Li, Q.X.4
-
17
-
-
0024835039
-
Electrochemical investigation of biotin-avidin interactions at a polycrystalline gold electrode
-
G.Y. Champagne, D. Belanger, and G. Fortier Electrochemical investigation of biotin-avidin interactions at a polycrystalline gold electrode Bioelectrochem. Bioenerg. 22 1989 159 165
-
(1989)
Bioelectrochem. Bioenerg.
, vol.22
, pp. 159-165
-
-
Champagne, G.Y.1
Belanger, D.2
Fortier, G.3
-
18
-
-
0000768569
-
Electrochemical sensors based on impedance measurement of enzyme catalysed polymer breakdown: Theory and applications
-
C.J. McNeil, D. Athey, M. Ball, W.O. Ho, S. Krause, R.D. Armstrong, J.D. Wright, and K. Rawson Electrochemical sensors based on impedance measurement of enzyme catalysed polymer breakdown: theory and applications Anal. Chem. 67 1995 3928 3935
-
(1995)
Anal. Chem.
, vol.67
, pp. 3928-3935
-
-
McNeil, C.J.1
Athey, D.2
Ball, M.3
Ho, W.O.4
Krause, S.5
Armstrong, R.D.6
Wright, J.D.7
Rawson, K.8
-
20
-
-
0037095315
-
Development of a confined wall-jet flow-through cell for simultaneous electrochemical and surface plasmon resonance applications
-
M. Bart, P.J.H.J. van Os, B. Kamp, and W.P. van Bennekom Development of a confined wall-jet flow-through cell for simultaneous electrochemical and surface plasmon resonance applications Sens. Actuat. B 84 2002 129 135
-
(2002)
Sens. Actuat. B
, vol.84
, pp. 129-135
-
-
Bart, M.1
Van Os, P.J.H.J.2
Kamp, B.3
Van Bennekom, W.P.4
-
21
-
-
0029349765
-
Utilization of a self-assembled peptide monolayer for an impedimetric immunosensor
-
P. Heiduschka, M. Knichel, W. Göpel, W. Beck, and G. Jung Utilization of a self-assembled peptide monolayer for an impedimetric immunosensor Sens. Actuat. B 28 1995 85 94
-
(1995)
Sens. Actuat. B
, vol.28
, pp. 85-94
-
-
Heiduschka, P.1
Knichel, M.2
Göpel, W.3
Beck, W.4
Jung, G.5
-
22
-
-
0031571838
-
Affinity biosensors based on a capacitive transducer
-
C. Berrgren, and G. Johansson Affinity biosensors based on a capacitive transducer Anal. Chem. 69 1997 3651 3657
-
(1997)
Anal. Chem.
, vol.69
, pp. 3651-3657
-
-
Berrgren, C.1
Johansson, G.2
-
23
-
-
0031244911
-
Capacitive sensor for the allatostatin direct immunoassay
-
A.R. Varlan, J. Suls, W. Sansen, D. Veelaert, and A.D. Loof Capacitive sensor for the allatostatin direct immunoassay Sens. Actuat. B 44 1997 334 340
-
(1997)
Sens. Actuat. B
, vol.44
, pp. 334-340
-
-
Varlan, A.R.1
Suls, J.2
Sansen, W.3
Veelaert, D.4
Loof, A.D.5
|