-
2
-
-
0023489716
-
Direct Immunochemical sensing: Basic chemical principles and fundamental limitations
-
M.J., Eddowes, Direct Immunochemical sensing: basic chemical principles and fundamental limitations, Biosensors, 3, 1987/1988, 1-5
-
(1987)
Biosensors
, vol.3
, pp. 1-5
-
-
Eddowes, M.J.1
-
4
-
-
0020880123
-
Microgravimetric immunoassay with piezoelectric crystals
-
J.E. Roeder, G.J. Bastiaans, Microgravimetric immunoassay with piezoelectric crystals, Anal. Chem. 55 (1983) 2333-2336.
-
(1983)
Anal. Chem.
, vol.55
, pp. 2333-2336
-
-
Roeder, J.E.1
Bastiaans, G.J.2
-
5
-
-
0024405872
-
Continuous liquid-phase piezoelectric biosensor for kinetic immunoassays
-
K.A. Davis, T.R. Leary, Continuous liquid-phase piezoelectric biosensor for kinetic immunoassays, Anal. Chem. 61 (1989) 1227-1230.
-
(1989)
Anal. Chem.
, vol.61
, pp. 1227-1230
-
-
Davis, K.A.1
Leary, T.R.2
-
6
-
-
0025611807
-
Development of a piezoimmunosensor fot the detection of Salmonella typhimurium
-
H. Okada, A. Tanaka, H.W. Blanch (Eds.), Enzyme Engineering
-
J.H.T. Luong, E. Prusak-Sochaczewski, G.G. Guilbault, Development of a piezoimmunosensor fot the detection of Salmonella typhimurium, in: H. Okada, A. Tanaka, H.W. Blanch (Eds.), Enzyme Engineering, Ann. NY Acad. Sci. 613 (1990) 439-443.
-
(1990)
Ann. NY Acad. Sci.
, vol.613
, pp. 439-443
-
-
Luong, J.H.T.1
Prusak-Sochaczewski, E.2
Guilbault, G.G.3
-
7
-
-
0021681339
-
Optical detection of antibody-antigen reactions at a glass-liquid interface
-
R.M. Shutherland, C. Dahne, J.F. Place, A.S. Ringrose, Optical detection of antibody-antigen reactions at a glass-liquid interface, Clin. Chem. 30 (1984) 1533-1538.
-
(1984)
Clin. Chem.
, vol.30
, pp. 1533-1538
-
-
Shutherland, R.M.1
Dahne, C.2
Place, J.F.3
Ringrose, A.S.4
-
8
-
-
0021802962
-
The preparation of bacterial luciferase conjugates for immunoassay and application to rubella antibody detection
-
E. Jablonsky, The preparation of bacterial luciferase conjugates for immunoassay and application to rubella antibody detection, Anal. Biochem. 148 (1985) 199-206.
-
(1985)
Anal. Biochem.
, vol.148
, pp. 199-206
-
-
Jablonsky, E.1
-
9
-
-
0026379121
-
Evaluation of the fiber optic antibody-based fluoroimmunosensor for DNA adducts in human placenta samples
-
T. Vo-Dinh, J.P. Alarie, R.W. Johnson, M.J. Sepaniak, R.M. Santella, Evaluation of the fiber optic antibody-based fluoroimmunosensor for DNA adducts in human placenta samples, Clin. Chem. 37 (1991) 532-535.
-
(1991)
Clin. Chem.
, vol.37
, pp. 532-535
-
-
Vo-Dinh, T.1
Alarie, J.P.2
Johnson, R.W.3
Sepaniak, M.J.4
Santella, R.M.5
-
10
-
-
0001798973
-
Planar waveguide immunosensor with fluorescente liposome amplification
-
S.J. Choquette, L. Locascio-Brown, R.A. Durst, Planar waveguide immunosensor with fluorescente liposome amplification, Anal. Chem. 61 (1992) 55-60.
-
(1992)
Anal. Chem.
, vol.61
, pp. 55-60
-
-
Choquette, S.J.1
Locascio-Brown, L.2
Durst, R.A.3
-
11
-
-
0025114626
-
Potentiometric biosensor employing catalytic antibodies as the molecular recognition element
-
G.F. Blackburn, D.B. Talley, P.M. Booth, C.N. Durfor, M.T. Martin, A.D. Napper, A.R. Rees, Potentiometric biosensor employing catalytic antibodies as the molecular recognition element, Anal. Chem. 62 (1990) 2211-2215.
-
(1990)
Anal. Chem.
, vol.62
, pp. 2211-2215
-
-
Blackburn, G.F.1
Talley, D.B.2
Booth, P.M.3
Durfor, C.N.4
Martin, M.T.5
Napper, A.D.6
Rees, A.R.7
-
12
-
-
0025242011
-
Heterogeneous enzyme immunoassay of alpha-fetoprotein in material serum by flow injection amperometric detection of 4-aminophenol
-
Y. Xu, B. Halshall, W.R. Heineman, Heterogeneous enzyme immunoassay of alpha-fetoprotein in material serum by flow injection amperometric detection of 4-aminophenol, Clin. Chem. 36 (1990) 1941-1944.
-
(1990)
Clin. Chem.
, vol.36
, pp. 1941-1944
-
-
Xu, Y.1
Halshall, B.2
Heineman, W.R.3
-
13
-
-
0025986469
-
Immunosensors
-
L.I. Blum, P.R. Coulet (Eds.), Dekker, New York
-
M. Aizawa, Immunosensors, in: L.I. Blum, P.R. Coulet (Eds.), Biosensors Principles and Applications, Dekker, New York, 1991, pp. 249-266.
-
(1991)
Biosensors Principles and Applications
, pp. 249-266
-
-
Aizawa, M.1
-
14
-
-
0008504341
-
The capacitive affinity sensor: A new biosensor
-
Bordeaux
-
A.L. Newman, K.W. Hunter, W.D. Stanbro, The capacitive affinity sensor: a new biosensor, Proceedings of the 2nd Meeting on Chemical Sensors, Bordeaux, 1986, pp. 596-598.
-
(1986)
Proceedings of the 2nd Meeting on Chemical Sensors
, pp. 596-598
-
-
Newman, A.L.1
Hunter, K.W.2
Stanbro, W.D.3
-
15
-
-
0025862232
-
Toxin detection using capacitance measurements on immunosensor grafted onto a semiconductor substrate
-
V. Billard, C. Martelet, P. Binder, J. Therasse, Toxin detection using capacitance measurements on immunosensor grafted onto a semiconductor substrate, Anal. Chim. Acta. 249 (1991) 367-372.
-
(1991)
Anal. Chim. Acta.
, vol.249
, pp. 367-372
-
-
Billard, V.1
Martelet, C.2
Binder, P.3
Therasse, J.4
-
16
-
-
0000318667
-
Real-time monitoring of immunochemical interactions wih a Tantalum capacitance flow-through cell
-
A. Gebbert, M. Alvarez-Icaza, W. Stocklein, R.D. Schmidt, Real-time monitoring of immunochemical interactions wih a Tantalum capacitance flow-through cell, Anal. Chem. 94 (1992) 997-1003.
-
(1992)
Anal. Chem.
, vol.94
, pp. 997-1003
-
-
Gebbert, A.1
Alvarez-Icaza, M.2
Stocklein, W.3
Schmidt, R.D.4
-
17
-
-
0029113375
-
Impedance based sensing of the specific binding reaction between Staphilococus enterotoxin B and its antibody on an ultra-thin platinum film
-
M.S. DeSilva, Y. Zhang, P.J. Hesketh, G.J. Maclay, S.M. Gendel, J.R. Stetter, Impedance based sensing of the specific binding reaction between Staphilococus enterotoxin B and its antibody on an ultra-thin platinum film, Biosensors Bioelectron. 10 (1995) 675-682.
-
(1995)
Biosensors Bioelectron.
, vol.10
, pp. 675-682
-
-
DeSilva, M.S.1
Zhang, Y.2
Hesketh, P.J.3
Maclay, G.J.4
Gendel, S.M.5
Stetter, J.R.6
-
18
-
-
0029324956
-
Monitoring of antibody-antigen reactions with affinity sensors: Experiments and models
-
M. Klein, R. Kates, N. Chucholowski, M. Schmitt, C. Lyden, Monitoring of antibody-antigen reactions with affinity sensors: experiments and models, Sensors and Actuators B 26-27 (1995) 474-476.
-
(1995)
Sensors and Actuators B
, vol.26-27
, pp. 474-476
-
-
Klein, M.1
Kates, R.2
Chucholowski, N.3
Schmitt, M.4
Lyden, C.5
-
19
-
-
0029349765
-
Utilisation of a self-assembled peptide monolayer for an impedimetric immunosensor
-
M. Knichel, P. Heiduschka, W. Beck, G. Jung, W. Gopel, Utilisation of a self-assembled peptide monolayer for an impedimetric immunosensor, Sensors and Actuators B 28 (1995) 85-94.
-
(1995)
Sensors and Actuators B
, vol.28
, pp. 85-94
-
-
Knichel, M.1
Heiduschka, P.2
Beck, W.3
Jung, G.4
Gopel, W.5
-
20
-
-
0003529772
-
-
Institute of Physics Publishing, Bristol
-
M. Lambrechts, W. Sansen, Biosensors: Microelectrochemical Devices, Sensors Series, Institute of Physics Publishing, Bristol, 1992.
-
(1992)
Biosensors: Microelectrochemical Devices, Sensors Series
-
-
Lambrechts, M.1
Sansen, W.2
-
22
-
-
0001720015
-
Allatostatin content of the brain, corpora allata and haemolymph at different developmental stages of the cockroach Diploptera punctata quantification by ELISA and bioassay
-
C.G. Yu, B. Stay, S. Joshi, S.S. Tobe, Allatostatin content of the brain, corpora allata and haemolymph at different developmental stages of the cockroach Diploptera punctata quantification by ELISA and bioassay, J. Insect Physiol. 38 (1993) 111-122.
-
(1993)
J. Insect Physiol.
, vol.38
, pp. 111-122
-
-
Yu, C.G.1
Stay, B.2
Joshi, S.3
Tobe, S.S.4
-
23
-
-
0021504736
-
Pething Dielectric properties of biological materials, biophysical and medical applications
-
Pething Dielectric properties of biological materials, biophysical and medical applications, IEEE Trans. Elec. Insul. EI-19 (1984) 453-474.
-
(1984)
IEEE Trans. Elec. Insul.
, vol.EI-19
, pp. 453-474
-
-
|