Study on quantitative methods of inspection and breakage diagnoses of high voltage line and cable by thermography

Author keywords

Breakage; Cable; High voltage line; Infrared thermography; Nondestructive testing (NDT)

Indexed keywords

CABLES; ELECTRIC CABLES; HEAT CONDUCTION; MATHEMATICAL MODELS; NUMERICAL ANALYSIS; TEMPERATURE DISTRIBUTION; TEMPERATURE MEASUREMENT;

EID: 27944434953     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (20)

References (14)
  • 1
    • 27944462118 scopus 로고    scopus 로고
    • Study on test methods of XLPE power cable rated up to 35 kV
    • Luo Junhua, Ma Cuijiao, Qiu Yuchang et al. Study on test methods of XLPE power cable rated up to 35 kV[J]. Power System Technology, 2000, 24(12): 58-61.
    • (2000) Power System Technology , vol.24 , Issue.12 , pp. 58-61
    • Luo, J.1    Ma, C.2    Qiu, Y.3
  • 2
    • 0032266971 scopus 로고    scopus 로고
    • Novel method for locating insulation failure of three-phase cables by bridge circuit
    • Ye Pengsheng, Dong Huaxia, Ye Jingbo. Novel method for locating insulation failure of three-phase cables by bridge circuit[J]. Proceedings of the CSEE, 1998, 18(5): 361-363.
    • (1998) Proceedings of the CSEE , vol.18 , Issue.5 , pp. 361-363
    • Ye, P.1    Dong, H.2    Ye, J.3
  • 3
    • 27944508585 scopus 로고    scopus 로고
    • Application of fiber optic distributed temperature sensor to fault detection of XLPE insulated underground cable
    • Zhang Xiaohong, Jiang Xiongwei, Wang Zhenhua et al. Application of fiber optic distributed temperature sensor to fault detection of XLPE insulated underground cable[J]. Power System Technology, 1999, 23(12): 36-38.
    • (1999) Power System Technology , vol.23 , Issue.12 , pp. 36-38
    • Zhang, X.1    Jiang, X.2    Wang, Z.3
  • 4
    • 13244297482 scopus 로고    scopus 로고
    • A wavelet reconstruction based fault location method for power cables
    • Xiong Xiaofu, Lin Jinhong. A wavelet reconstruction based fault location method for power cables[J]. Power System Technology, 2003, 27(6): 36-38.
    • (2003) Power System Technology , vol.27 , Issue.6 , pp. 36-38
    • Xiong, X.1    Lin, J.2
  • 5
    • 84966428847 scopus 로고    scopus 로고
    • Theory and experiment of a cable fault location method based on impedance and using frequency-variable source
    • Wang Wei, Cai Wei, Zhang Yuanfang et al. Theory and experiment of a cable fault location method based on impedance and using frequency-variable source[J]. Power System Technology, 2001, 25(11): 38-41.
    • (2001) Power System Technology , vol.25 , Issue.11 , pp. 38-41
    • Wang, W.1    Cai, W.2    Zhang, Y.3
  • 6
    • 21644456104 scopus 로고    scopus 로고
    • Study on detection of partial discharge in XLPE cable at higher frequency
    • Luo Junhua, Feng Jiang, Yuan Jian et al. Study on detection of partial discharge in XLPE cable at higher frequency[J]. Power System Technology, 2001, 25(12): 42-45.
    • (2001) Power System Technology , vol.25 , Issue.12 , pp. 42-45
    • Luo, J.1    Feng, J.2    Yuan, J.3
  • 7
    • 0033224128 scopus 로고    scopus 로고
    • Surface temperature field based online diagnoses study for electric cable's conductor temperature
    • Zhao Jianhua, Yuan Hongyong, Fan Weicheng et al. Surface temperature field based online diagnoses study for electric cable's conductor temperature[J]. Proceedings of the CSEE, 1999, 19(1): 52-54.
    • (1999) Proceedings of the CSEE , vol.19 , Issue.1 , pp. 52-54
    • Zhao, J.1    Yuan, H.2    Fan, W.3
  • 8
    • 27944454648 scopus 로고    scopus 로고
    • A breakage down diagnostic system for high-voltage transmission-line by infrared ray
    • Dai Jinchun, Wu Gongping, Guo Yinglong et al. A breakage down diagnostic system for high-voltage transmission-line by infrared ray[J]. Journal of Wuhan University of Hydraulic and Electric Engineering, 1998, 31(2): 61-64.
    • (1998) Journal of Wuhan University of Hydraulic and Electric Engineering , vol.31 , Issue.2 , pp. 61-64
    • Dai, J.1    Wu, G.2    Guo, Y.3
  • 9
    • 27944472975 scopus 로고    scopus 로고
    • Infrared ray detection and fault diagnosis of mechanical fault on high voltage lines
    • Wu Gongping, Dai Jinchun, Guo Yinglong et al. Infrared ray detection and fault diagnosis of mechanical fault on high voltage lines[J]. Chinese Journal of Scientific Instrument, 1999, 20(6): 571-574.
    • (1999) Chinese Journal of Scientific Instrument , vol.20 , Issue.6 , pp. 571-574
    • Wu, G.1    Dai, J.2    Guo, Y.3
  • 10
    • 27944462516 scopus 로고    scopus 로고
    • Chinese source
  • 11
    • 27944455106 scopus 로고    scopus 로고
    • Chinese source
  • 12
    • 0032639716 scopus 로고    scopus 로고
    • On the NDT and E for the diagnosis of defects using infrared thermography
    • Inagaki T, Ishii T, Iwamoto T. On the NDT and E for the diagnosis of defects using infrared thermography[J]. NDT&E International, 1999, 32(5): 247-257.
    • (1999) NDT&E International , vol.32 , Issue.5 , pp. 247-257
    • Inagaki, T.1    Ishii, T.2    Iwamoto, T.3
  • 13
    • 27944477162 scopus 로고    scopus 로고
    • Calculation and error analysis of temperature measurement using thermal imager
    • Yang Li. Calculation and error analysis of temperature measurement using thermal imager[J]. Infrared Technology, 1999, 21(4): 20-24.
    • (1999) Infrared Technology , vol.21 , Issue.4 , pp. 20-24
    • Yang, L.1
  • 14
    • 27944500121 scopus 로고    scopus 로고
    • Study on detection of pipeline wall thinning by infrared NDT
    • Fan Chunli, Sun Fengrui, Yang Li. Study on detection of pipeline wall thinning by infrared NDT[J]. Laser and Infrared, 2004, 34(6): 452-454.
    • (2004) Laser and Infrared , vol.34 , Issue.6 , pp. 452-454
    • Fan, C.1    Sun, F.2    Yang, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.